9V9788 PLATE-LH Caterpillar parts
   
 
 
Rating:
 Alternative (cross code) number:
CA9V9788
9V-9788
9V9788
 
CA9V9788
9V-9788
9V9788
 
  Weight: 2 pounds 1 kg. 
  Information:
Always wear goggles when working on air conditioning systems. The system is under pressure at all times, engine running or not. Escaping Freon-12 (C C12F2 Dichloro Difluoro Methane) can cause freezing of human flesh.Do not smoke while working on air conditioning systems. Inhaling Freon-12 through any smoking material, although not toxic or flammable, can generate phosgene gas and cause violent illness. Also, heat must never be applied to a charged system. See Air Conditioning And Heating Service Manual, Form No. SENR3334, for more information on removal and installation of lines and refrigerant from the system.
1. Release the pressure in the air conditioning system. See the topic, Purging The System, in Air Conditioning And Heating Service Manual, Form No. SENR3334. 2. Disconnect hose assemblies (5) and (6) from the air conditioning compressor. Put plugs and caps on all of the openings.3. Remove three bolts and guard assembly (4) from the front of the air conditioning compressor.4. Disconnect two wires (1) from the air conditioning compressor.5. Loosen two nuts (2) to release the tension on the V-belt. Remove the V-belt from the pulley on the air conditioning compressor.6. Remove the nut that holds the adjusting rod to the compressor.7. Remove the bolts that hold air conditioning compressor (3) to the bracket, and remove the compressor. The following steps are for installation of the air conditioning compressor.8. Put air conditioning compressor (3) in position on the bracket, and install the bolts that hold it in place.9. Put the adjusting rod in position on the air conditioning compressor, and install the nut that holds it.10. Put the V-belt in position on the pulley. Use two nuts (2) to adjust the belt tension. Use a belt tension gauge such as a Borroughs Tool Company (Part No. BT-33-95), or equivalent, to check the belt tension. The belt tension reading should be 120 5 for a new belt or 90 10 for a used belt.11. Connect two wires (1) to the air conditioning compressor.12. Put guard assembly (4) in position, and install the bolts that hold it in place.13. Connect hose assemblies (5) and (6).14. See Air Conditioning And Heating Service Manual, Form No. SENR3334, for the correct procedure for evacuating and charging the system.
Parts plate Caterpillar catalog:
 9V9787
PLATE A-RH
 
Caterpillar
 
Caterpillar
 9V9618
PLATE A LH
 
Caterpillar
 
Caterpillar
 9V9568
PLATE A-LH
 
Caterpillar
 
Caterpillar
 9V9567
PLATE A-RH
 
Caterpillar
 
Caterpillar
 9V9464
PLATE A-LH
 
Caterpillar
 
Caterpillar
 9V9461
PLATE A-RH
 
Caterpillar
  
Caterpillar
 9W0462
PLATE
 
Caterpillar
 
Caterpillar
 9W0372
PLATE
 
Caterpillar
 
Caterpillar
 9W0315
PLATE-RH
 
Caterpillar
 
Caterpillar
 9W0233
PLATE-INNER -
 
Caterpillar
 
Caterpillar
 9W0200
PLATE A
 
Caterpillar
 
Caterpillar
 9W0120
PLATE
 
Caterpillar
 
Caterpillar