3315208 PLATFORM AS Caterpillar parts
785C
Rating:
Alternative (cross code) number:
CA3315208
331-5208
3315208
CA3315208
331-5208
3315208
Weight: 770 pounds 349 kg.
TRUCK,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 3315208:
Information:
Installation Procedure
Identify a location for installation of the bottle. Ensure that the location for installation is protected. Ensure that the location of the bottle is lower than the nozzle.Follow the steps that are listed below in order to install the bottle.
Locate the nozzle in a horizontal position less than 3.0m (10 ft) away from the bottle.
Locate the bottle no lower than 1.5 m (5 ft) from the nozzle.
Inspect the location for the installation and ensure that welding in the location will not damage any of the nearby components.
Illustration 3 g01341843
Typical Location of Installation for the Bottle
Weld the bosses onto the frame in order to mount the bottle.
Install the bottle for the cleaning system.
Mount the nozzle.The following requirements need to be followed for the installation of the nozzle.
Illustration 4 g01341929
For optimal performance install the nozzle within 25 mm (1 inch) of the camera lens.Note: When installing the nozzle ensure that the nozzle is not viewable in the camera image.
The nozzle needs to be angled at 45 degrees from the surface of the lens.
Illustration 5 g01338194
Nozzle
Mount the spray nozzle so that the projection of the spray cuts at the base of the glass.
Install the wiring harness. Route the wiring harness with the existing wiring harnesses.
Illustration 6 g01341873
Typical Installation of the Wiring Harness
Install the power wire to the pump. Install the ground wire to the pump. Refer to Illustration 9 for a system schematic.
Locate an suitable ground and Install the other end of the ground wire to the frame.
Locate a location for installation in the cab of the machine for the washer switch.
Illustration 7 g01341911
Typical Installation of the Washer Switch
Connect the cleaning system to an appropriately fused 24 volt power source.
Illustration 8 g01338195
Check Valve
Route the fluid line from the pump to the nozzle. Cut the fluid line and install the check valve no more than 304 mm (1 ft) away from the tank. Ensure that the arrow on the check valve is pointed away from the pump.Note: You must prime the pump before installing the check valve. In order to prime the pump allow the water to flow out of the line in order to purge the air out of the line.
Check the operation of the system.Wiring Schematic
Illustration 9 g01341969
System Connections
Identify a location for installation of the bottle. Ensure that the location for installation is protected. Ensure that the location of the bottle is lower than the nozzle.Follow the steps that are listed below in order to install the bottle.
Locate the nozzle in a horizontal position less than 3.0m (10 ft) away from the bottle.
Locate the bottle no lower than 1.5 m (5 ft) from the nozzle.
Inspect the location for the installation and ensure that welding in the location will not damage any of the nearby components.
Illustration 3 g01341843
Typical Location of Installation for the Bottle
Weld the bosses onto the frame in order to mount the bottle.
Install the bottle for the cleaning system.
Mount the nozzle.The following requirements need to be followed for the installation of the nozzle.
Illustration 4 g01341929
For optimal performance install the nozzle within 25 mm (1 inch) of the camera lens.Note: When installing the nozzle ensure that the nozzle is not viewable in the camera image.
The nozzle needs to be angled at 45 degrees from the surface of the lens.
Illustration 5 g01338194
Nozzle
Mount the spray nozzle so that the projection of the spray cuts at the base of the glass.
Install the wiring harness. Route the wiring harness with the existing wiring harnesses.
Illustration 6 g01341873
Typical Installation of the Wiring Harness
Install the power wire to the pump. Install the ground wire to the pump. Refer to Illustration 9 for a system schematic.
Locate an suitable ground and Install the other end of the ground wire to the frame.
Locate a location for installation in the cab of the machine for the washer switch.
Illustration 7 g01341911
Typical Installation of the Washer Switch
Connect the cleaning system to an appropriately fused 24 volt power source.
Illustration 8 g01338195
Check Valve
Route the fluid line from the pump to the nozzle. Cut the fluid line and install the check valve no more than 304 mm (1 ft) away from the tank. Ensure that the arrow on the check valve is pointed away from the pump.Note: You must prime the pump before installing the check valve. In order to prime the pump allow the water to flow out of the line in order to purge the air out of the line.
Check the operation of the system.Wiring Schematic
Illustration 9 g01341969
System Connections
Caterpillar parts catalog:
Parts platform Caterpillar catalog:
1632633
PLATFORM GP
777D, 785C, 789C, 789D, 793C
777D, 785C, 789C, 789D, 793C
5T3220
PLATFORM GP-RH
784B, 784C, 785, 785B, 785C
784B, 784C, 785, 785B, 785C
3318551
PLATFORM GP
785C
785C
1490966
PLATFORM GP
777D, 785C
777D, 785C
3097916
PLATFORM GP
785C
785C
2854206
PLATFORM AS
776C, 777D, 785B, 785C, 789B, 789C
776C, 777D, 785B, 785C, 789B, 789C
3881464
PLATFORM AS
784B, 784C, 785B, 785C
784B, 784C, 785B, 785C
1490967
PLATFORM AS
777D, 785C
777D, 785C
1609853
PLATFORM AS
777D, 785C, 789C, 789D, 793C
777D, 785C, 789C, 789D, 793C
3604901
PLATFORM AS
784C, 785C, 785D, 789C, 797, 797B
784C, 785C, 785D, 789C, 797, 797B
2352032
PLATFORM AS
785C
785C
3113359
PLATFORM AS
785C
785C
3113359
PLATFORM AS
785C
785C
2284211
PLATFORM AS
793C
793C
2151463
PLATFORM AS
785D, 789C, 793C, 793D, 793F
785D, 789C, 793C, 793D, 793F
2352032
PLATFORM AS
785C
785C
3604901
PLATFORM AS
784C, 785C, 785D, 789C, 797, 797B
784C, 785C, 785D, 789C, 797, 797B
1609853
PLATFORM AS
777D, 785C, 789C, 789D, 793C
777D, 785C, 789C, 789D, 793C
2266262
PLATFORM AS
793C
793C
2062021
PLATFORM AS
793C
793C
2062020
PLATFORM AS
793C
793C
1527189
PLATFORM AS
797, 797B
797, 797B
1566440
PLATFORM AS
797, 797B
797, 797B
3272728
PLATFORM AS
793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F XQ, 797, 797B, 797F
793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F XQ, 797, 797B, 797F