0020492 PLUG Caterpillar parts
Rating:
Alternative (cross code) number:
CA0020492
002-0492
0020492
CA0020492
002-0492
0020492
Weight: 0.20 pounds 0 kg.
Information:
Illustration 1 g01094676
This diagnostic code is associated with an internal problem with one of the devices for the AccuGrade Laser system. An unknown device is detected.Test Step 1. CYCLE THE POWER TO THE SYSTEM
Move the "Power/Setup" Switch for the display to the "OFF" position.
Turn the key start switch for the machine to the "OFF" position.
Turn the key start switch for the machine to the "ON" position.
Move the "Power/Setup" Switch for the display to the "ON" position.Expected Result:The diagnostic code becomes inactive.Results:
YES - The diagnostic code becomes inactive. Return the machine to normal operation.STOP
NO - The diagnostic code is still active. Proceed to Test Step 2.Test Step 2. CHECK THE HARNESS FOR AN OPEN.
Move the "Power/Setup" Switch for the display to the "OFF" position.
Turn the key start switch and the disconnect switch for the machine to the OFF position.
Disconnect the harness from the connector that is located on the right radiator guard.
Measure the resistance between pin "B" and pin "F".Expected Result:The resistance is less than 5.0 ohms.Results:
OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - The resistance is greater than 5000 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.Repair: The open is in wire T744-WH of the machine harness. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK THE HARNESS FOR A SHORT.
Move the "power/setup" switch on the display to the OFF position.
Turn the key start switch and the disconnect switch for the machine to the OFF position.
Disconnect the harness from the connector that is located on the left radiator guard.
Measure the resistance between pin "B" and pin "F".Expected Result:The resistance is greater than 5000 ohms.Results:
OK - The resistance is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 4.
NOT OK - The resistance is less than 5000 ohms. The resistance measurement is not correct. There is an short circuit in the machine harness.Repair: The short is in wire T744-WH of the machine harness. Repair the machine harness or replace the machine harness.STOPTest Step 4. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the contacts of the harness connectors and clean the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Move the "power/setup" switch on the display to the ON position.
Operate the machine.
Check the status of the "CB 23".Expected Result:The "CB 23" diagnostic code is active.Results:
YES - The "CB 23" diagnostic code is active. The diagnostic code has not been corrected. Repair: Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, contact your Technical communicator for a possible consultation withCaterpillar.STOP
NO - The "CB 23" diagnostic code is not active. The diagnostic code does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP
Parts plug Caterpillar catalog:
0020320
PLUG
Caterpillar
Caterpillar
0018371
PLUG
Caterpillar
Caterpillar
0017205
PLUG
Caterpillar
Caterpillar
0016938
PLUG
Caterpillar
Caterpillar
0016640
PLUG
Caterpillar
Caterpillar
0016637
PLUG
Caterpillar
Caterpillar
0022463
PLUG
Caterpillar
Caterpillar
0021653
PLUG
Caterpillar
Caterpillar
0021621
PLUG
Caterpillar
Caterpillar
0021061
PLUG
Caterpillar
Caterpillar
0020691
PLUG
Caterpillar
Caterpillar
0020559
PLUG
Caterpillar
Caterpillar