0931322 PLUG Caterpillar parts
307, 307B, 307C, 308C, 63, CB-535B, CB-544, CB-545, E110B, E120B, E300, E450, E650, E70B, R1300, R1600, R1600G, SAT420, SAT630, W330B, W345B II, W345C MH
Rating:
Alternative (cross code) number:
CA0931322
093-1322
0931322
CA0931322
093-1322
0931322
Weight: 0.15 pounds 0 kg.
Information:
DASH SIZE
000000000008
HEX SIZE
0
mm
OVERALL LENGTH
17
mm
THREAD SIZE
.50-14BSPP
WITH THREAD SEALANT
N
EXCAVATOR, WHEELED EXCAVATOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$3.24
21 May 2022
0.11[0.05] Pounds
LU: Amazon Global S
DECORA Thin Cake Board, Cardboard, Gold, 20 x 20 x 0.3 cm
DECORA singularly shrink-wrapped || height cm 1,2 || in cellulose pulp coated with coloured aluminium thin but resistant as a common cake board || thin but resistant as a common cake board
DECORA singularly shrink-wrapped || height cm 1,2 || in cellulose pulp coated with coloured aluminium thin but resistant as a common cake board || thin but resistant as a common cake board
Compatible equipment models: 0931322:
Information:
Electrical Shock Hazard. The electronic unit injectors use DC voltage. The ECM sends this voltage to the electronic unit injectors. Do not come in contact with the harness connector for the electronic unit injectors while the engine is operating. Failure to follow this instruction could result in personal injury or death.
During the following procedure, refer to the electrical schematic for the application.Complete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps Values Results
1. Inspect Electrical Connectors and Wiring
A. Turn the keyswitch to the OFF position. A strong electrical shock hazard is present if the keyswitch is not turned OFF.
B. Thoroughly inspect the connectors at the cylinder head. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
C. Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with injector solenoids.
D. Check the screw for the ECM connector for the correct torque of 6 N m (53 lb in).
E. Check the harness and wiring for abrasion and for pinch points from the injectors to the ECM.
Loose connection or damaged wire
Result: There is a fault in a connector or the wiring.
Repair: Repair any faulty connectors or replace the wiring harness. Ensure that all the seals are properly in place and ensure that the connectors are correctly coupled.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: All connectors, pins, and sockets are correctly coupled and/or inserted. The harness is free of corrosion, abrasion, and pinch points.
Proceed to Test Step 2.
2. Use the "Injector Solenoid Test"
A. Start the engine.
B. Allow the engine to warm to the normal operating temperature.
C. Stop the engine.
D. Turn the keyswitch to the ON position.
E. Access the "Injector Solenoid Test" by accessing the following display screens in order:
"Diagnostics"
"Diagnostic Tests"
"Injector Solenoid Test"
F. Activate the test.
Note: Do not confuse the "Injector Solenoid Test" with the "Cylinder Cutout Test". The "Cylinder Cutout Test" is used to shut off fuel to a specific cylinder while the engine is running. The "Injector Solenoid Test" is used to actuate the injector solenoids while the engine is not running.
"OK", "OPEN", or "SHORT"
Result: All cylinders indicate "OK". There is not an electronic fault with the injectors.
Use the electronic service tool to clear all logged diagnostic codes. Return the engine to service.
Result: "OPEN"
Note the cylinders that indicate "OPEN".
Proceed to Test Step 3.
Result: "SHORT"
Note the cylinders that indicate "SHORT".
Proceed to Test Step 4.
3. Check the Harness between the ECM and the Cylinder Head for an Open Circuit
A. Turn the keyswitch to the OFF position. A strong electrical shock hazard is present if the keyswitch is not turned OFF.
B. Disconnect the connector for the suspect injector from the cylinder head.
C. Fabricate a jumper wire 100 mm (4 inch) long with terminals on both ends of the wire.
D. Insert one end of the jumper wire into the terminal for the supply to the suspect injector. Insert the other end of the jumper wire into the terminal
Cat SIS web machinery list:
Parts plug Caterpillar catalog:
1076531
PLUG
304.5, 307, 307B
304.5, 307, 307B
1431632
PLUG-BEZEL
303, 304, 305, 305.5, 305.5E, 306, 306E, 307B
303, 304, 305, 305.5, 305.5E, 306, 306E, 307B
1397841
PLUG
305.5, 306, 307B, 307C, 307D, 308C, 308D
305.5, 306, 307B, 307C, 307D, 308C, 308D
1398266
PLUG
305.5, 306, 307B, 307C, 307D, 308C
305.5, 306, 307B, 307C, 307D, 308C
1348700
PLUG
305.5, 307B, 307C, 308C
305.5, 307B, 307C, 308C
0857451
PLUG
305.5, 307B, 307C, 308C
305.5, 307B, 307C, 308C
1719342
PLUG
304.5, 305, 305.5, 306, 307B, 307C, 308C
304.5, 305, 305.5, 306, 307B, 307C, 308C
1985022
PLUG
304, 304.5, 305, 305.5, 306, 307B, 307C, 308C
304, 304.5, 305, 305.5, 306, 307B, 307C, 308C
0966073
PLUG
307B, 307C, 308C, 308E2 CR, 311D LRR, 311F LRR, 312C L, 312D, 312D L, 312D2, 312E, 314D CR, 314D LCR, 314E CR, 315D L, 316E L, 319D L, 319D LN, 320D, 320D L, 320D LRR, 320D RR, 320D2, 320D2 L, 320E, 3...
307B, 307C, 308C, 308E2 CR, 311D LRR, 311F LRR, 312C L, 312D, 312D L, 312D2, 312E, 314D CR, 314D LCR, 314E CR, 315D L, 316E L, 319D L, 319D LN, 320D, 320D L, 320D LRR, 320D RR, 320D2, 320D2 L, 320E, 3...
1799758
PLUG
304, 304.5, 304C CR, 305, 305.5, 305.5D, 305.5E, 305C CR, 306, 307B, 307C, 308C
304, 304.5, 304C CR, 305, 305.5, 305.5D, 305.5E, 305C CR, 306, 307B, 307C, 308C
1799757
PLUG
307B, 307C, 308C
307B, 307C, 308C
1505733
PLUG
307B, 307C, 308C, 330C, 330D L, 330D MH, 345B II, 345B II MH, 345C, 345C L, 345C MH, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L HVG, 349E L VG, 349F L, W345B II, W345C MH
307B, 307C, 308C, 330C, 330D L, 330D MH, 345B II, 345B II MH, 345C, 345C L, 345C MH, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L HVG, 349E L VG, 349F L, W345B II, W345C MH