1645619 PLUG AS Caterpillar parts
120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H,...
Rating:
Alternative (cross code) number:
CA1645619
164-5619
1645619
CA1645619
164-5619
1645619
Weight: 0.010 pounds 0 kg.
AG TRANSMISSION, WHEEL TRACTOR-SCRAPER,
This part in 2 request:
Show.
This information for suppliers only!
2020-12-04
2018-08-03
Compatible equipment models: 1645619:
ASPHALT PAVER
AP-1000B
AP-1000E
AP-1055B
AP-1055D
AP-1055E
AP-555E
AP-600D
AP-650B
AP-655C
AP-655D
AP-800C
AP-800D
AP-900B
BG-225B
BG-225C
BG-2455D
BG-245C
BG-260D
BG1000E
BG1055E
BG500E
BG600D
BG655D
COMPACT WHEEL LOADER
910G
EXCAVATOR
324D
324D FM
324D FM LL
324D L
324D LN
325D
325D FM
325D FM LL
325D L
325D MH
329D
329D L
329D LN
330D
330D FM
330D L
330D LN
330D MH
336D
336D L
336D LN
336D2
336D2 L
340D2 L
345D
345D L
345D L VG
349D
349D L
349E
349E L
349E L VG
349F L
374D L
374F L
390D
390D L
390F L
M325D L MH
M325D MH
FORWARDER
574
HAMMER
H110E S
INDUSTRIAL ENGINE
3126B
LOAD HAUL DUMP
R2900G
LOGGER
322C
MOTOR GRADER
120H
120H ES
120H NA
120K
120K 2
120M
120M 2
12H
12H ES
12H NA
12K
12M
12M 2
12M 3
12M 3 AWD
135H
135H NA
140H
140H ES
140H NA
140K
140K 2
140M
140M 2
140M 3
140M 3 AWD
143H
14M
160H
160H ES
160H NA
160K
160M
160M 2
160M 3
160M 3 AWD
163H
163H NA
16H
16H NA
16M
24M
PETROLEUM ENGINE
C9
PIPELAYER
561N
PUMPER
SPF343C
QUARRY TRUCK
771D
TRACK FELLER BUNCHER
TK1051
TRACK LOADER
973D
TRACK-TYPE TRACTOR
D10T2
D11N
D11R
D11T
D3G
D4G
D5G
D5N
D6H
D6H XL
D6H XR
D6N
D6R
D6R II
D6R III
D6R STD
D6T
D6T LGP
D6T LGPPAT
D6T XL
D7E
D7E LGP
D7R
D7R II
D7R XR
D8N
D8R
D8R II
D8T
D9R
TRACTOR
776D
TRUCK
769D
770
770G
770G OEM
772
772G
772G OEM
773D
773E
773F
773G
773G LRC
773G OEM
775E
775F
775G
775G LRC
775G OEM
777D
777F
777G
793F CMD
797
797B
797F
TRUCK ENGINE
C7
WHEEL LOADER
924H
924HZ
928H
928HZ
938H
950G
950G II
950H
950K
962G
962G II
962H
962K
966G
966G II
966H
966K
966M
966M XE
972G
972G II
972H
972K
972M
972M XE
980C
980K
980K HLG
980M
982M
986H
992D
Information:
Generator Loading
When a generator is installed or reconnected, be sure that the total current in one phase does not exceed the nameplate rating. Each phase should carry the same load, allowing the engine to work at its rated capacity. An electrical unbalance can result in an electrical overload and overheating if one phase current exceeds the nameplate amperage.Block Loading
Block Loading is the instantaneous application of an electrical load to a generator set. This load may be anywhere from a moderate percentage of the rated load up to the rated load itself.The block loading capability of a generator set depends upon engine transient response, voltage regulator response and type, altitude of operation, type of load, and the amount of load at the time the block load is applied.If a block load derating is required, refer to ISO 3046 or SAE J1349 Standards. Also reference Engine Data Sheets, Block Loading Transient Response LEKX4066 and Transient Response LEKX4067.Power Factor
Power factor may be thought of as the efficiency of the load - the ratio of apparent power to total power. Power factor is expressed as a decimal and denotes that portion of current supplied to a system doing useful work. The portion of current not doing useful work is absorbed in maintaining the magnetic field in motors. This current, although it is called the reactive load, does not require engine power to maintain it.In most applications electric motors and transformers determine the power factor of the system. Induction motors usually have a 0.8 or smaller power factor. Incandescent lighting is a resistive load of about 1.0 power factor, or unity.The power factor of a system may be determined by a power factor meter or by calculations. Determine the power requirement in kW by multiplying the power factor by the KVA supplied to the system. As the power factor goes up, the total current supplied to a constant power demand will go down. A 100 kW load at a 0.8 power factor will draw more current than a 100 kW load at 0.9 power factor. High power factor will result in full engine load at less than generator rated amperage. Conversely, a lower power factor increases the possibility of overloading the generator. Caterpillar SR4 HV Generators are designed at 0.8 power factor, unless otherwise specified.Low Idle Adjustment
Electric sets normally have a higher low idle setting than do industrial engines. Low idle will be approximately 2/3 the full speed of 60 Hz units (4/5 full load speed of 50 Hz units).On electric sets with some Woodward governors and Caterpillar electronic governors, there is no low idle stop. On electric sets with mechanical governors and natural gas electric sets, the low idle is set at the factory, and should only be adjusted by your Caterpillar dealer if adjustment ifs required. Operating the electric set at low idle speed for an extended time will cause some voltage regulators to shut off. The electric set must be completely shut down and restarted to allow the voltage regulator
When a generator is installed or reconnected, be sure that the total current in one phase does not exceed the nameplate rating. Each phase should carry the same load, allowing the engine to work at its rated capacity. An electrical unbalance can result in an electrical overload and overheating if one phase current exceeds the nameplate amperage.Block Loading
Block Loading is the instantaneous application of an electrical load to a generator set. This load may be anywhere from a moderate percentage of the rated load up to the rated load itself.The block loading capability of a generator set depends upon engine transient response, voltage regulator response and type, altitude of operation, type of load, and the amount of load at the time the block load is applied.If a block load derating is required, refer to ISO 3046 or SAE J1349 Standards. Also reference Engine Data Sheets, Block Loading Transient Response LEKX4066 and Transient Response LEKX4067.Power Factor
Power factor may be thought of as the efficiency of the load - the ratio of apparent power to total power. Power factor is expressed as a decimal and denotes that portion of current supplied to a system doing useful work. The portion of current not doing useful work is absorbed in maintaining the magnetic field in motors. This current, although it is called the reactive load, does not require engine power to maintain it.In most applications electric motors and transformers determine the power factor of the system. Induction motors usually have a 0.8 or smaller power factor. Incandescent lighting is a resistive load of about 1.0 power factor, or unity.The power factor of a system may be determined by a power factor meter or by calculations. Determine the power requirement in kW by multiplying the power factor by the KVA supplied to the system. As the power factor goes up, the total current supplied to a constant power demand will go down. A 100 kW load at a 0.8 power factor will draw more current than a 100 kW load at 0.9 power factor. High power factor will result in full engine load at less than generator rated amperage. Conversely, a lower power factor increases the possibility of overloading the generator. Caterpillar SR4 HV Generators are designed at 0.8 power factor, unless otherwise specified.Low Idle Adjustment
Electric sets normally have a higher low idle setting than do industrial engines. Low idle will be approximately 2/3 the full speed of 60 Hz units (4/5 full load speed of 50 Hz units).On electric sets with some Woodward governors and Caterpillar electronic governors, there is no low idle stop. On electric sets with mechanical governors and natural gas electric sets, the low idle is set at the factory, and should only be adjusted by your Caterpillar dealer if adjustment ifs required. Operating the electric set at low idle speed for an extended time will cause some voltage regulators to shut off. The electric set must be completely shut down and restarted to allow the voltage regulator
Cat SIS web machinery list:
Parts plug Caterpillar catalog:
6N9590
PLUG-DRAIN
24H, 5110B, 5130, 5130B, 5230, 5230B, 631E, 631G, 633E II, 637D, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771C, 771D, 772B, 773B, 773D, 773E, 775B, 775D, 775E, 776C, 776D, 777, 777B, 777D, 784B, 784C,...
24H, 5110B, 5130, 5130B, 5230, 5230B, 631E, 631G, 633E II, 637D, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771C, 771D, 772B, 773B, 773D, 773E, 775B, 775D, 775E, 776C, 776D, 777, 777B, 777D, 784B, 784C,...
1381510
PLUG
525B, 525D, 535B, 535D, 545, 545D, 555D, 611, 613C II, 615C, 725, 730, 735, 740, 770, 772, 772G, 772G OEM, 797, 814F, 814F II, 815B, 815F, 815F II, 816F, 816F II, 844, 844H, 844K, 854G, 854K, 950G, 95...
525B, 525D, 535B, 535D, 545, 545D, 555D, 611, 613C II, 615C, 725, 730, 735, 740, 770, 772, 772G, 772G OEM, 797, 814F, 814F II, 815B, 815F, 815F II, 816F, 816F II, 844, 844H, 844K, 854G, 854K, 950G, 95...
1149487
PLUG
621F, 627F
621F, 627F
3119548
PLUG
330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 336E, 336E HVG, 336E L, 336E LN, 340D L, 340D2 L, 568 FM LL, 904H, M330D
330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 336E, 336E HVG, 336E L, 336E LN, 340D L, 340D2 L, 568 FM LL, 904H, M330D
6D1639
PLUG
650B, 69D, 768B, 769, 769C, 769D, 771C, 771D
650B, 69D, 768B, 769, 769C, 769D, 771C, 771D
9T6865
PLUG-ADAPTER
336E, 336E H, 336E HVG, 336E L, 336E LH, 336E LN, 336F L, 349E, 349E L, 349E L HVG, 349E L VG, 349F L, 374F L, 568 FM LL, 769C, 769D, 771C, 771D, 772B, 773B, 773D, 775B, 775D, 776C, 776D, 777B, 777C, ...
336E, 336E H, 336E HVG, 336E L, 336E LH, 336E LN, 336F L, 349E, 349E L, 349E L HVG, 349E L VG, 349F L, 374F L, 568 FM LL, 769C, 769D, 771C, 771D, 772B, 773B, 773D, 775B, 775D, 776C, 776D, 777B, 777C, ...
6E5047
PLUG
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H NA, 12K, 135H, 135H NA, 140H, 140H NA, 140K, 140K 2, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 16H, 16H NA, 16M, 320 L, 320N, 322, ...
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H NA, 12K, 135H, 135H NA, 140H, 140H NA, 140K, 140K 2, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 16H, 16H NA, 16M, 320 L, 320N, 322, ...
6V3963
PLUG-MAGNETIC
793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 797
793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 797
3050692
PLUG AS
AD30, AD45B, AD55, AD55B, AD60, R1300G II, R1700G, R2900G, R3000H
AD30, AD45B, AD55, AD55B, AD60, R1300G II, R1700G, R2900G, R3000H
1120000
PLUG
350, 385B, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L, 5090B
350, 385B, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L, 5090B
1838177
PLUG
320C, 320C FM, 320C L, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LRR, 320D RR, 323D L, 323D LN
320C, 320C FM, 320C L, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LRR, 320D RR, 323D L, 323D LN
2097383
PLUG AS
115, 63, H140DS, H55DS
115, 63, H140DS, H55DS
1363742
PLUG-FELT
16G, 16H NA, 24H, 24M, 3126, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412E, 3456, 3516, 3516C, 375, 375 L, 385B, 5080, 5090B, 578, 583R, 583T, 587R, 587T, 621B, 621E, 621F, ...
16G, 16H NA, 24H, 24M, 3126, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412E, 3456, 3516, 3516C, 375, 375 L, 385B, 5080, 5090B, 578, 583R, 583T, 587R, 587T, 621B, 621E, 621F, ...
7W6534
PLUG-PIPE
16G, 16H NA, 245D, 24H, 24M, 3054, 3054B, 3056, 3204, 325 L, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 3456, 3508, 3512, 3512B, 3516, 3516B, 375, 375 L, 385B, 50...
16G, 16H NA, 245D, 24H, 24M, 3054, 3054B, 3056, 3204, 325 L, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 3456, 3508, 3512, 3512B, 3516, 3516B, 375, 375 L, 385B, 50...
1656170
PLUG
16G, 16H NA, 24H, 24M, 3056, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 3456, 365C, 365C L, 365C L MH, 374D L, 374F L, 375, 375 L, 385B, 385C, 385C FS, 385C L, 38...
16G, 16H NA, 24H, 24M, 3056, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 3456, 365C, 365C L, 365C L MH, 374D L, 374F L, 375, 375 L, 385B, 385C, 385C FS, 385C L, 38...
9L7657
PLUG-CUP
1140, 1145, 1150, 1160, 120G, 130G, 215, 225, 227, 231D, 3160, 3204, 3208, 3304, 3304B, 3406, 3406B, 3406C, 3406E, 3456, 365C, 365C L, 365C L MH, 374D L, 385B, 385C, 385C FS, 385C L, 385C L MH, 390D, ...
1140, 1145, 1150, 1160, 120G, 130G, 215, 225, 227, 231D, 3160, 3204, 3208, 3304, 3304B, 3406, 3406B, 3406C, 3406E, 3456, 365C, 365C L, 365C L MH, 374D L, 385B, 385C, 385C FS, 385C L, 385C L MH, 390D, ...
3095130
PLUG AS
2384C, 2484C, 3126, 3126B, 3126E, 320D2, 320D2 GC, 320D2 L, 323D2 L, 3406C, 3406E, 3456, 375, 375 L, 5080, 517, 518C, 527, 528B, 530B, 559C, 561N, 572R II, 579C, 583T, 621G, 623G, 627E, 627F, 627G, 62...
2384C, 2484C, 3126, 3126B, 3126E, 320D2, 320D2 GC, 320D2 L, 323D2 L, 3406C, 3406E, 3456, 375, 375 L, 5080, 517, 518C, 527, 528B, 530B, 559C, 561N, 572R II, 579C, 583T, 621G, 623G, 627E, 627F, 627G, 62...
2014340
PLUG AS
140H, 143H, 14H, 160H, 163H, 16H, 24M, 3406E, 385C, 385C FS, 385C L, 385C L MH, 583T, 627G, 631G, 637D, 637E, 637G, 657E, 657G, 725, 730, 735, 740, 770, 772, 773F, 773G, 773G LRC, 773G OEM, 775F, 775G...
140H, 143H, 14H, 160H, 163H, 16H, 24M, 3406E, 385C, 385C FS, 385C L, 385C L MH, 583T, 627G, 631G, 637D, 637E, 637G, 657E, 657G, 725, 730, 735, 740, 770, 772, 773F, 773G, 773G LRC, 773G OEM, 775F, 775G...
1691518
PLUG
TH62, TH82
TH62, TH82
1981877
PLUG AS
924G, TH103, TH62, TH63, TH82, TH83
924G, TH103, TH62, TH63, TH82, TH83
1144226
PLUG
446B, 446D, CP-433B
446B, 446D, CP-433B
2183597
PLUG-ORIFICE
416D, 420D, 420E, 420F, 424D, 428D, 428E, 428F, 430D, 430E, 430F, 432D, 432E, 432F, 434E, 434F, 438D, 442D, 442E, 444E, 444F, 446B, 446D, 450E, 450F
416D, 420D, 420E, 420F, 424D, 428D, 428E, 428F, 430D, 430E, 430F, 432D, 432E, 432F, 434E, 434F, 438D, 442D, 442E, 444E, 444F, 446B, 446D, 450E, 450F
3E7188
PLUG-CONNECTOR
446B, CS-563C
446B, CS-563C
1503072
PLUG AS
14M, 16M, 236D, 242D, 246C, 246D, 256C, 257D, 259D, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C, 289C2, 289D, 297C, 299C, 299D, 307B, 315C, 3...
14M, 16M, 236D, 242D, 246C, 246D, 256C, 257D, 259D, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C, 289C2, 289D, 297C, 299C, 299D, 307B, 315C, 3...