Information:
This procedure is used in order to monitor a switch on the machine. Some typical examples are listed below:
Any switch that sends a signal directly to a warning indicator in the cab of a machine
A sensor that sends a signal to a relay switch
On existing switches, refer to the Electrical System Schematic for the machine. Determine the wire that is the ground wire and determine the wire that is the signal wire. Note: When you are adding a new switch to a machine, connect the ground wire from the switch to frame ground. Connect the signal wire from the sensor directly to the 8 Pin Connector on the wiring harness for the Product Link. Go directly to step 10.
Determine a suitable location for splicing into the existing signal wire. The recommended location is at an existing connector in the wiring harness.
Trace the wiring to the connector, or use the electrical schematic to determine the proper connector pin for the wire. On DT connectors, remove the wire with the 147-6456 Wedge Removal Tool .
Insert a 199-9785 Wire into the empty socket in the connector.
Use a 175-3700 Connector Repair Kit in order to create a 2-pin male DT connector on the two wires from 199-9785 Wire .
Use a 175-3700 Connector Repair Kit to create a receptacle for the 2-pin connector.
Connect the existing wire that was removed in step 3 into one socket in the receptacle.
Prepare an appropriate length of wire to run from the receptacle to the Product Link module. Connect one end of this wire into the second socket in the connector receptacle.
Connect the receptacle and plug together.
Illustration 1 g00794175
Run the wire that was prepared in step 8 to the 8 pin connector on the wiring harness for the Product Link. This harness is illustrated in Systems Operation, "System Components". Follow the recommended procedures for routing wiring that was explained in the installation of the Product Link module.
At the 8-Pin connector, connect the wire to the first available contact. The available contacts for the additional switched inputs are 3, 4, 6 and 7.
Connect the Electronic Technician (ET) to the machine. If you are unfamiliar with ET, see Troubleshooting, "Service Tools".
Illustration 2 g00658333
Start the Electronic Technician. After starting the ET, a list of electronic control modules is shown on the screen. Select the Product Link.
Illustration 3 g00682621
Select the "Configuration" menu from the ET screen.
Illustration 4 g00663492
After the list of configurable parameters is displayed, select "Digital Sensor Input #1 Type Configuration". This is shown in illustration 4.Note: Select a spare input that is labelled as "Not Configured".
Select the proper configuration for the normal state of the switch. Click "OK" after making the selection.
Illustration 5 g00663490
Select the "Digital Sensor Input #1 Description" and type in an appropriate description for the switch. This is shown in illustration 5. Click "OK" after entering the description.
Illustration 6 g00663477
Select the "Digital Sensor Input #1 Delay Time" and type in the delay time in seconds. This is shown in illustration 6. Click "OK" after entering the delay.
Illustration 7 g00686021
Go to the "Status" screens
Any switch that sends a signal directly to a warning indicator in the cab of a machine
A sensor that sends a signal to a relay switch
On existing switches, refer to the Electrical System Schematic for the machine. Determine the wire that is the ground wire and determine the wire that is the signal wire. Note: When you are adding a new switch to a machine, connect the ground wire from the switch to frame ground. Connect the signal wire from the sensor directly to the 8 Pin Connector on the wiring harness for the Product Link. Go directly to step 10.
Determine a suitable location for splicing into the existing signal wire. The recommended location is at an existing connector in the wiring harness.
Trace the wiring to the connector, or use the electrical schematic to determine the proper connector pin for the wire. On DT connectors, remove the wire with the 147-6456 Wedge Removal Tool .
Insert a 199-9785 Wire into the empty socket in the connector.
Use a 175-3700 Connector Repair Kit in order to create a 2-pin male DT connector on the two wires from 199-9785 Wire .
Use a 175-3700 Connector Repair Kit to create a receptacle for the 2-pin connector.
Connect the existing wire that was removed in step 3 into one socket in the receptacle.
Prepare an appropriate length of wire to run from the receptacle to the Product Link module. Connect one end of this wire into the second socket in the connector receptacle.
Connect the receptacle and plug together.
Illustration 1 g00794175
Run the wire that was prepared in step 8 to the 8 pin connector on the wiring harness for the Product Link. This harness is illustrated in Systems Operation, "System Components". Follow the recommended procedures for routing wiring that was explained in the installation of the Product Link module.
At the 8-Pin connector, connect the wire to the first available contact. The available contacts for the additional switched inputs are 3, 4, 6 and 7.
Connect the Electronic Technician (ET) to the machine. If you are unfamiliar with ET, see Troubleshooting, "Service Tools".
Illustration 2 g00658333
Start the Electronic Technician. After starting the ET, a list of electronic control modules is shown on the screen. Select the Product Link.
Illustration 3 g00682621
Select the "Configuration" menu from the ET screen.
Illustration 4 g00663492
After the list of configurable parameters is displayed, select "Digital Sensor Input #1 Type Configuration". This is shown in illustration 4.Note: Select a spare input that is labelled as "Not Configured".
Select the proper configuration for the normal state of the switch. Click "OK" after making the selection.
Illustration 5 g00663490
Select the "Digital Sensor Input #1 Description" and type in an appropriate description for the switch. This is shown in illustration 5. Click "OK" after entering the description.
Illustration 6 g00663477
Select the "Digital Sensor Input #1 Delay Time" and type in the delay time in seconds. This is shown in illustration 6. Click "OK" after entering the delay.
Illustration 7 g00686021
Go to the "Status" screens
Caterpillar parts catalog:
Parts plug Caterpillar catalog:
1910312
PLUG
303, 304, 305
303, 304, 305
2146197
PLUG
303, 303E CR, 304, 305, 305.5, 305.5E, 306, 306E, 308E, 308E2 CR, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 318D L, 318D2 L, 320D L, 320D2, 320D2 GC, 320D2 L, 324D L, 326D L, 329D L, 336D, 336...
303, 303E CR, 304, 305, 305.5, 305.5E, 306, 306E, 308E, 308E2 CR, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 318D L, 318D2 L, 320D L, 320D2, 320D2 GC, 320D2 L, 324D L, 326D L, 329D L, 336D, 336...
8C5224
PLUG-SEAL
16M, 303, 303.5C, 304, 304D CR, 305, 305.5, 306, 924H, 924HZ, 928H, 928HZ, 953C, 963C, 973C, D11N, D11R, D11T
16M, 303, 303.5C, 304, 304D CR, 305, 305.5, 306, 924H, 924HZ, 928H, 928HZ, 953C, 963C, 973C, D11N, D11R, D11T
1958445
PLUG
304, 305
304, 305
1958440
PLUG
301.6C, 304, 305
301.6C, 304, 305
1958267
PLUG
301.6C, 304, 305
301.6C, 304, 305
1691115
PLUG
305
305
1373687
PLUG
304, 304C CR, 305, 305.5D, 305.5E, 305C CR, 305D CR, 305E, 312B, 315B, 315B FM L
304, 304C CR, 305, 305.5D, 305.5E, 305C CR, 305D CR, 305E, 312B, 315B, 315B FM L
1988423
PLUG
303.5C, 303.5D, 303.5E, 303C CR, 303E CR, 304, 304C CR, 304D CR, 304E, 305, 305.5, 305.5D, 305.5E, 305C CR, 305D CR, 305E, 306, 308E, 308E CR, 308E SR, 904H
303.5C, 303.5D, 303.5E, 303C CR, 303E CR, 304, 304C CR, 304D CR, 304E, 305, 305.5, 305.5D, 305.5E, 305C CR, 305D CR, 305E, 306, 308E, 308E CR, 308E SR, 904H
1988420
PLUG
303, 303.5C, 303.5D, 303.5E, 303C CR, 303E CR, 304, 304C CR, 304D CR, 304E, 305, 305.5, 305.5D, 305.5E, 305C CR, 305D CR, 305E, 306, 308E, 308E CR, 308E SR, 904H
303, 303.5C, 303.5D, 303.5E, 303C CR, 303E CR, 304, 304C CR, 304D CR, 304E, 305, 305.5, 305.5D, 305.5E, 305C CR, 305D CR, 305E, 306, 308E, 308E CR, 308E SR, 904H
2963111
PLUG-DRAIN
303, 303.5C, 303.5D, 303C CR, 304, 304C CR, 304D CR, 305, 305.5D, 305C CR, 305D CR, 904H
303, 303.5C, 303.5D, 303C CR, 304, 304C CR, 304D CR, 305, 305.5D, 305C CR, 305D CR, 904H
1991146
PLUG
305, 305.5, 306
305, 305.5, 306