4779535 POWER TRAIN AR Caterpillar parts
Rating:
Alternative (cross code) number:
CA4779535
477-9535
4779535
CA4779535
477-9535
4779535
Information:
Illustration 1 g02642625
Schematic of the Implement Pilot Supply Solenoid
This diagnostic code is associated with the Implement Pilot Supply Solenoid. The FMI 06 means that the ECM has detected that the current for the solenoid circuit is above normal.The following conditions could cause this diagnostic code to be activated:
The energize circuit of the solenoid is shorted to a ground source.
The solenoid has failed.
The ECM has failed. The failure of the ECM is unlikely. Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit meet the following requirements: clean, secure and good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.Note: Use a calibrated digital multimeter for the measurements in this procedure.System Response:
All implement functions will stop working.Test Step 1. CHECK THE SOLENOID
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness. Expected Result:The active CID 0358 FMI 06 diagnostic code changes to a CID 0358 FMI 05 diagnostic code when the solenoid is disconnected.Results:
YES - The active CID 0358 FMI 06 diagnostic code changes to a CID 0358 FMI 05 diagnostic code when the solenoid is disconnected. The solenoid circuit in the machine harness is correct.Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid.STOP
NO - The CID 0358 FMI 06 diagnostic code remains active. Disconnecting the solenoid did not change the status of the active diagnostic code. The solenoid is not causing the problem. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUNDThe solenoid remains disconnected from the machine harness.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness ECM connectors J1 and J2 from the ECM.
At the machine harness ECM connectors, measure the resistance from the signal contact J1-12 wire H717-BR(Brown)to frame ground. Measure the resistance from the signal contact J1-12 wire H717-BR(Brown)to all of the other contacts that are used in J1 and J2 ECM connectors.
While observing the multimeter resistance measurements, wiggle the machine harness connectors for the ECM and the solenoid. Gently pull on the wires and move the wires all around.Expected Result:Each resistance measurement is greater than 5000 ohms at all times during the manipulation of the harness and connectors.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - One or more of the resistance measurements are less than 5000 ohms. The resistance
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts power Caterpillar catalog:
4779533
POWER TRAIN AR
Caterpillar
Caterpillar
4625269
POWER TRAIN AR
Caterpillar
Caterpillar
4508640
POWER TRAIN AR
Caterpillar
Caterpillar
4508631
POWER TRAIN AR
Caterpillar
Caterpillar
4508616
POWER TRAIN AR
Caterpillar
Caterpillar
4508610
POWER TRAIN AR
Caterpillar
Caterpillar
5479067
POWER TRAIN AR
Caterpillar
Caterpillar
5476095
POWER TRAIN AR
Caterpillar
Caterpillar
5151820
POWER TRAIN AR
Caterpillar
Caterpillar
5063406
POWER TRAIN AR
Caterpillar
Caterpillar
5063405
POWER TRAIN AR
Caterpillar
Caterpillar
4945810
POWER TRAIN AR
Caterpillar
Caterpillar