1687722 PROBE- Caterpillar parts
Rating:
Alternative (cross code) number:
CA1687722
168-7722
1687722
CA1687722
168-7722
1687722
Weight: 0.22 pounds 0 kg.
Information:
Illustration 2 g01363321
(5) Right motor case drain line
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.Dispose of all fluids according to local regulations and mandates.
Perform the following:
Install adapters (C) and (D) at location (4).
Attach flow meter (B) to the adapters.
Connect flow meter (B) to viewing tool (A).Ensure that viewing tool (A) is visible from the cab.
Perform the following:
Install adapters (C) and (D) at location (5).
Attach flow meter (B) to the adapters.
Connect flow meter (B) to viewing tool (A).Ensure that viewing tool (A) is visible from the cab.
Start the machine.
Before testing the All Wheel Drive system (AWD), warm the oil to 50 °C to 60 °C (122 °F to 140 °F).
Set the engine speed to high idle.
Engage the parking brake.
Ensure that the AWD system is OFF.
Check the flow from each motor case. The flow should be 4 1 L/min (1.1 0.3 US gpm).
If the flow is less than 3 L/min (0.8 US gpm), perform the following steps:
Check for low charge pressure.
Replace the relief valve in the motor.
Replace the motor. The flushing valve is integrated in the motor. The flushing valve is not serviceable separately.
If the flow is greater than 5 L/min (1.3 US gpm), perform the following steps:
Check for high charge pressure.
Replace the relief valve in the motor.
Replace the motor. The flushing valve is integrated in the motor. The flushing valve is not serviceable separately.
With the engine at high idle, turn the AWD system to "CREEP" mode.
Slowly move the machine in the forward direction.
Stall the front wheels. Use the following items in order to stall the front wheels:
The service brakes
A steep slope
A stationary object
The flushing flow from each motor should be approximately 10 2 L/min (2.6 0.5 US gpm).
If the flow is less than 8 L/min (2.1 US gpm), perform the following steps:
Check for low charge pressure.
Replace the relief valve in the motor.
Replace the motor. The flushing valve is integrated in the motor. The flushing valve is not serviceable separately.
If the flow is greater than 12 L/min (3.2 US gpm), perform the following steps:
Check for high charge pressure.
Replace the relief valve in the motor.
Replace the motor. The flushing valve is integrated in the motor. The flushing valve is not serviceable separately.
Shut down the machine.
Remove all tooling.
Reconnect all connections that were broken for the test. Test of the Motor Case Pressure
Note: Do not perform this test if the flow meters from the previous test are installed. The flow meters add additional restriction. The flow meters will raise the pressure above specifications.
Table 2
Required Tools
Tool Part Number Description Qty
E 198-4240 Digital Pressure Indicator 1
F 198-4237 Pressure Sensor Gp (500 PSI) 2
G 8K-4739 Adapter 2
H 110-6349 Fitting As 2
Illustration
Parts probe Caterpillar catalog:
1642192
PROBE-PRESSURE
Caterpillar
Caterpillar
1555176
PROBE-AC/DC
Caterpillar
Caterpillar
1555175
PROBE-
Caterpillar
Caterpillar
0980954
PROBE
Caterpillar
Caterpillar
0909742
PROBE
Caterpillar
Caterpillar
0908510
PROBE
Caterpillar
Caterpillar
3008650
PROBE-TEST
Caterpillar
Caterpillar
2S0944
PROBE A.
Caterpillar
Caterpillar
2095552
PROBE AS.-GAS
Caterpillar
Caterpillar
1U7759
PROBE AS-
Caterpillar
Caterpillar
1U6246
PROBE-
Caterpillar
Caterpillar
1U6236
PROBE
Caterpillar
Caterpillar