Schematic of the "Auxiliary Circuit Flow Combining" Solenoids
This diagnostic code is associated with the auxiliary circuit for the solenoid valves (flow combining). The FMI 06 means that the Machine ECM has determined that the current of the solenoids is above normal. The possible causes of this diagnostic code are listed below:
The energize circuit of the solenoids is shorted to ground.
One or both solenoids has failed.
The Machine ECM has failed. This is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1931 FMI 06 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.Test Step 1. CHECK THE SOLENOIDS.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoids with the active diagnostic code from the machine harness. Expected Result:The CID 1931 FMI 06 diagnostic code changes to a CID 1931 FMI 05 diagnostic code when the solenoids are disconnected.Results:
YES - The CID 1931 FMI 06 diagnostic code changes to a CID 1931 FMI 05 diagnostic code when the solenoids are disconnected. The circuit is correct.Repair: One or both solenoids have failed. Repeat this test "CHECK THE SOLENOIDS" in order to verify the solenoid failure. Replace the failed solenoid.STOP
NO - The CID 1931 FMI 06 remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOIDS FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The solenoid remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the Machine ECM.
At the machine harness connector, measure the resistance from the signal contact J2-10 (wire K871-WH(White)) to all contacts that are used in the machine harness connectors for the Machine ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-10 (wire K871-WH(White)) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors. Clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 1931 FMI 06 diagnostic code. Expected Result:The CID 1931 FMI 06 diagnostic code is active. Results:
YES - The CID 1931 FMI 06 diagnostic code is active. The diagnostic code has not been corrected. The Machine ECM may have failed.Repair: It is unlikely that the Machine ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code
Parts puller Caterpillar catalog:
 8B7545
PULLER A.
 
Caterpillar
 
Caterpillar
 8B2893
PULLER A.-OIL
 
Caterpillar
 
Caterpillar
 7M8826
PULLER-WHEEL
 
Caterpillar
 
Caterpillar
 7H1970
PULLER G.-V.
 
Caterpillar
 
Caterpillar
 7F9540
PULLER A
 
Caterpillar
 
Caterpillar
 7F1857
PULLER A CYL
 
Caterpillar
  
Caterpillar
 8E5902
PULLER AR-PIN
 
Caterpillar
 
Caterpillar
 8E1929
PULLER AR-PIN
 
Caterpillar
 
Caterpillar
 8C1890
PULLER A
 
Caterpillar
 
Caterpillar
 8B7554
PULLER A.
 
Caterpillar
 
Caterpillar
 8B7548
PULLER AS-PUSH
 
Caterpillar
 
Caterpillar
 8B7547
PULLER A.
 
Caterpillar
 
Caterpillar
 
 
 