2S6149 PULLEY Caterpillar parts
631C, 657, 657B, 666, 983
Rating:
Alternative (cross code) number:
CA2S6149
2S-6149
2S6149
CA2S6149
2S-6149
2S6149
Weight: 13 pounds 6 kg.
Information:
DIAMETER OVER PINS
165.202
mm
GROOVE WIDTH
22.3
mm
NUMBER OF GROOVES
3
TRACK LOADER, WHEEL TRACTOR,
You can buy:
Compatible equipment models: 2S6149:
Information:
Underwriters Laboratories (UL) 2200
IMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONSThis manual contains important instructions for all Cat UL Listed stationary engine generator assembly models, that should be followed during installation, and maintenance of the generator and batteries.Load Connections – Generator Set Output
For units equipped with ABB Tmax® circuit breaker: Installer shall connect and size conductors based upon ampacities found in the 75° C (167° F) column within Table 310.15(B) of the "National Electrical Code®, ANSI/NFPA 70". An ampacity of no less than 115 percent (115%) of the maximum rated circuit current during normal operating conditions shall be used. All conductor insulation shall be rated 90° C (194° F) or greater.For units equipped with power terminal strips: UL Listed field wiring terminals shall be sized for the connection of a conductor having an ampacity based upon ampacities found in the 75° C (167° F) column within Table 310.15(B) of the "National Electrical Code®, ANSI/NFPA 70". An ampacity of no less than 115 percent (115%) of the maximum rated circuit current during normal operating conditions shall be used. All conductor insulation shall be rated 90° C (194° F) or greater. Field wiring terminals shall be installed in accordance with tooling and instructions recommended by their manufacturer. A field wiring terminal shall be sized for the connection of a conductor having an ampacity based on the 75° C (167° F) column of Table 310.15(B) of the "National Electrical Code®, ANSI/NFPA 70", of no less than 115 percent of the maximum current that the circuit carries during rated conditions. All conductors shall be rated 90° C (194° F) or greater.Installation Access:
This stationary engine generator assembly shall be installed so that access is restricted to only qualified service personnel who have been instructed of the reasons for the restrictions applied to the location, and about any precautions that must be taken. Access shall be by using a special tool, or lock and key, or other means of security and shall be controlled by the authority responsible for the location.Batteries and Servicing:
This stationary engine generator assembly utilizes one battery to produce a nominal 12V DC power supply.Battery servicing is to be performed or supervised by qualified personnel knowledgeable of batteries and the required precautions. Keep unauthorized and unqualified personnel away from batteries.When replacing batteries, use the same number and the following type batteries: lead-acid, vented type.
Table 1
Engine     Number of Batteries     Battery Voltage     Connected In:     Minimum CCA Battery    
C6.6     1     12 VDC     N/A     500    
C7.1     1     12 VDC     N/A     500    
Do not dispose of battery or batteries in a fire. The battery is capable of exploding.
Do not open or mutilate the battery or batteries. Released electrolyte has been known to be harmful to the skin and eyes and to be toxic.
A battery presents a risk of electrical shock and high short circuit current. The following precautions are to be observed when working on batteries:
Remove watches, rings, or other
IMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONSThis manual contains important instructions for all Cat UL Listed stationary engine generator assembly models, that should be followed during installation, and maintenance of the generator and batteries.Load Connections – Generator Set Output
For units equipped with ABB Tmax® circuit breaker: Installer shall connect and size conductors based upon ampacities found in the 75° C (167° F) column within Table 310.15(B) of the "National Electrical Code®, ANSI/NFPA 70". An ampacity of no less than 115 percent (115%) of the maximum rated circuit current during normal operating conditions shall be used. All conductor insulation shall be rated 90° C (194° F) or greater.For units equipped with power terminal strips: UL Listed field wiring terminals shall be sized for the connection of a conductor having an ampacity based upon ampacities found in the 75° C (167° F) column within Table 310.15(B) of the "National Electrical Code®, ANSI/NFPA 70". An ampacity of no less than 115 percent (115%) of the maximum rated circuit current during normal operating conditions shall be used. All conductor insulation shall be rated 90° C (194° F) or greater. Field wiring terminals shall be installed in accordance with tooling and instructions recommended by their manufacturer. A field wiring terminal shall be sized for the connection of a conductor having an ampacity based on the 75° C (167° F) column of Table 310.15(B) of the "National Electrical Code®, ANSI/NFPA 70", of no less than 115 percent of the maximum current that the circuit carries during rated conditions. All conductors shall be rated 90° C (194° F) or greater.Installation Access:
This stationary engine generator assembly shall be installed so that access is restricted to only qualified service personnel who have been instructed of the reasons for the restrictions applied to the location, and about any precautions that must be taken. Access shall be by using a special tool, or lock and key, or other means of security and shall be controlled by the authority responsible for the location.Batteries and Servicing:
This stationary engine generator assembly utilizes one battery to produce a nominal 12V DC power supply.Battery servicing is to be performed or supervised by qualified personnel knowledgeable of batteries and the required precautions. Keep unauthorized and unqualified personnel away from batteries.When replacing batteries, use the same number and the following type batteries: lead-acid, vented type.
Table 1
Engine     Number of Batteries     Battery Voltage     Connected In:     Minimum CCA Battery    
C6.6     1     12 VDC     N/A     500    
C7.1     1     12 VDC     N/A     500    
Do not dispose of battery or batteries in a fire. The battery is capable of exploding.
Do not open or mutilate the battery or batteries. Released electrolyte has been known to be harmful to the skin and eyes and to be toxic.
A battery presents a risk of electrical shock and high short circuit current. The following precautions are to be observed when working on batteries:
Remove watches, rings, or other
Caterpillar parts catalog:
Parts pulley Caterpillar catalog:
4N2697
PULLEY
245, 245B, 245D, 375, 375 L, 5080, 578, 583R, 587R, 621, 621B, 621E, 621F, 621G, 623E, 623F, 623G, 627E, 627F, 627G, 651B, 657B, 824C, 826C, 980C, 980F, 983B, D8N, D8R, D8R II, R2900, R2900G, R3000H
245, 245B, 245D, 375, 375 L, 5080, 578, 583R, 587R, 621, 621B, 621E, 621F, 621G, 623E, 623F, 623G, 627E, 627F, 627G, 651B, 657B, 824C, 826C, 980C, 980F, 983B, D8N, D8R, D8R II, R2900, R2900G, R3000H
9M2411
PULLEY
16, 631C, 657, 666, 769, 824B, 825B, 834, 983, 988
16, 631C, 657, 666, 769, 824B, 825B, 834, 983, 988
7M4052
PULLEY
641, 651, 666
641, 651, 666
7M7579
PULLEY
657
657
4M6183
PULLEY ASSEM.
651, 666
651, 666
8S5407
PULLEY
631C
631C
7M9677
PULLEY
651, 666, 824
651, 666, 824
9S7756
PULLEY
657B
657B
2P8767
PULLEY
631C
631C
2P8764
PULLEY
631C
631C
5M1812
PULLEY
657
657
8M8334
PULLEY
657
657
5S2876
PULLEY
983
983
6N6934
PULLEY
943
943
6N1705
PULLEY
594H, D9H
594H, D9H
2P3807
PULLEY
D6C
D6C
2P1129
PULLEY
583K, D8K
583K, D8K
6N0753
PULLEY
D5, D5B
D5, D5B
6N0764
PULLEY ASSEM.
D5, D5B
D5, D5B
6N0714
PULLEY
571G, 572G, D7G, D7G2
571G, 572G, D7G, D7G2
6N0699
PULLEY
D5, D5B
D5, D5B
4N8090
PULLEY
D9G, D9H
D9G, D9H
2P1126
PULLEY
D8K
D8K