3N5602 PULLEY-FAN DRIVE Caterpillar parts
3208, 3304, 3306, 3306B, CB-534, G3304, G3306, G3306B
Rating:
Alternative (cross code) number:
CA3N5602
3N-5602
3N5602
CA3N5602
3N-5602
3N5602
Weight: 11 pounds 5 kg.
Information:
DIAMETER OVER PINS
239.624
mm
GROOVE WIDTH
12.7
mm
NUMBER OF GROOVES
3
ENGINE - MACHINE, VIBRATORY COMPACTOR,
Compatible equipment models: 3N5602:
Information:
Table 1
Method for determining flow loss    
    Pump flow at
690 kPa (100 psi)        
-     Pump flow at
6900 kPa (1000 psi)        
    Flow loss        
Table 2
Example of determining flow loss    
   
2176 L/min (57.5 US gpm)        
-    
196.8 L/min (52.0 US gpm)        
   
20.8 L/min (5.5 US gpm)        Flow loss is used as a measure of pump performance. Flow loss is expressed as a percentage of pump flow.
Table 3
Method of determining percent of flow loss    
Flow loss (L/min or US gpm)     ×     100     =     Percent of flow loss    
Pump flow at
690 kPa (100 psi)    
Table 4
Example of determining percent of flow loss    
20.8 L (5.5 US gal)     ×     100     =     9.5%    
217.6 L/min (57.5 US gpm)    If the percent of flow loss is greater than 10%, the pump performance is inadequate.Note: The values in the examples are not set values for any specific pump or for any specific pump condition. Refer to the Hydraulic Specifications, RENR2028 for the pump flow of a new pump at 690 kPa (100 psi) and at 6900 kPa (1000 psi).Test on the Machine
Install a flow meter. Run the engine at high idle. Measure the pump flow at 690 kPa (100 psi), and at 6900 kPa (1000 psi). Use these values in the following formula.
Table 5
Method of determining percent of flow loss    
Flow loss (L/min or US gpm)     ×     100     =     Percent of flow loss    
Pump flow at
690 kPa (100 psi)    Test on the Bench
If the test bench can be run at 6900 kPa (1000 psi) and at full pump rpm, determine the percent of flow loss by using the above formula.If the test bench can not be run at 6900 kPa (1000 psi) or at full pump rpm, run the pump shaft at 1000 rpm. Measure the pump flow at 690 kPa (100 psi) and at 6900 kPa (1000 psi). Use these values in the top portion of the following formula. For the bottom part of the formula, run the pump shaft at 2000 rpm. Measure the pump flow at 690 kPa (100 psi).
Table 6
    Pump flow at
690 kPa (100 psi)                    
-     Pump flow at
6900 kPa (1000 psi)     ×     100     =     Percent of flow loss    
    Pump flow at
690 kPa (100 psi) and at 2000 rpm    
Caterpillar parts catalog:
Parts pulley Caterpillar catalog:
7C3729
PULLEY-ALTERNATOR
205B, 214B, 3114, 3116, 3126, 3306, 3306B, 910E, 918F, 924F, 928F, 938F, 938G, AP-1000B, AP-1055B, AP-900B, BG-2455C, BG-245C, CB-434, CB-634, CB-634C, CP-563, CS-531, CS-531C, CS-533, CS-533C, CS-563...
205B, 214B, 3114, 3116, 3126, 3306, 3306B, 910E, 918F, 924F, 928F, 938F, 938G, AP-1000B, AP-1055B, AP-900B, BG-2455C, BG-245C, CB-434, CB-634, CB-634C, CP-563, CS-531, CS-531C, CS-533, CS-533C, CS-563...
8L8867
PULLEY
3116, 3126, 3304, 3304B, 3306, 3306B, 330B L, 637D, CB-534, D250B, D250E, D250E II, D25C, D25D, D300B, D300D, D300E, D300E II, D30C, D350C, D35C, G3304B, G3306B
3116, 3126, 3304, 3304B, 3306, 3306B, 330B L, 637D, CB-534, D250B, D250E, D250E II, D25C, D25D, D300B, D300D, D300E, D300E II, D30C, D350C, D35C, G3304B, G3306B
7W5692
PULLEY-CRANKSHAFT
3304, 3304B, 3306, 3306B, 3306C, CB-534, D250E, D250E II, D300E, D300E II, G3304, G3304B, G3306, G3306B
3304, 3304B, 3306, 3306B, 3306C, CB-534, D250E, D250E II, D300E, D300E II, G3304, G3304B, G3306, G3306B
4N4679
PULLEY-FAN DRIVE
3304, 3304B, 3306, 3306B, D250B, G3304, G3304B, G3306, G3306B
3304, 3304B, 3306, 3306B, D250B, G3304, G3304B, G3306, G3306B
8L4529
PULLEY-ALTERNATOR
3304, 3304B, 3306, 3306B, G3304, G3304B, G3306, G3306B
3304, 3304B, 3306, 3306B, G3304, G3304B, G3306, G3306B
9N3899
PULLEY-PUMP DRIVE
225, 3208, 613B, 613C, FB221, PR-1000, PS-500
225, 3208, 613B, 613C, FB221, PR-1000, PS-500
4N6810
PULLEY ASSEM.
3208
3208
7L0412
PULLEY
3304, 3306, G3306
3304, 3306, G3306
8L5435
PULLEY
3304
3304
8L5436
PULLEY
3304
3304
8L4530
PULLEY
3304, 3306
3304, 3306
7L0200
PULLEY
3304
3304
4N4679
PULLEY-FAN DRIVE
3304, 3304B, 3306, 3306B, D250B, G3304, G3304B, G3306, G3306B
3304, 3304B, 3306, 3306B, D250B, G3304, G3304B, G3306, G3306B
3N6127
PULLEY-CRANKSHAFT
3304, 3304B, 3306, 3306B, 3306C, G3304, G3304B, G3306, G3306B
3304, 3304B, 3306, 3306B, 3306C, G3304, G3304B, G3306, G3306B
7W5686
PULLEY-CRANKSHAFT
3304, 3304B, 3306, 3306B
3304, 3304B, 3306, 3306B
7W5692
PULLEY-CRANKSHAFT
3304, 3304B, 3306, 3306B, 3306C, CB-534, D250E, D250E II, D300E, D300E II, G3304, G3304B, G3306, G3306B
3304, 3304B, 3306, 3306B, 3306C, CB-534, D250E, D250E II, D300E, D300E II, G3304, G3304B, G3306, G3306B
3N9603
PULLEY-FAN DRIVE
3304, 3306
3304, 3306
8L8867
PULLEY
3116, 3126, 3304, 3304B, 3306, 3306B, 330B L, 637D, CB-534, D250B, D250E, D250E II, D25C, D25D, D300B, D300D, D300E, D300E II, D30C, D350C, D35C, G3304B, G3306B
3116, 3126, 3304, 3304B, 3306, 3306B, 330B L, 637D, CB-534, D250B, D250E, D250E II, D25C, D25D, D300B, D300D, D300E, D300E II, D30C, D350C, D35C, G3304B, G3306B
4P7086
PULLEY-ALTERNATOR
416B, 428B, 438B
416B, 428B, 438B
8L4897
PULLEY-ALTERNATOR
3304, 3304B, 3306, 3306B, D343, G3304, G3304B, G3306, G3306B
3304, 3304B, 3306, 3306B, D343, G3304, G3304B, G3306, G3306B
8L4529
PULLEY-ALTERNATOR
3304, 3304B, 3306, 3306B, G3304, G3304B, G3306, G3306B
3304, 3304B, 3306, 3306B, G3304, G3304B, G3306, G3306B
8N2253
PULLEY
1673C, 3304, 3306, 3306B
1673C, 3304, 3306, 3306B
8N2110
PULLEY-FAN DRIVE
1673C, 3304, 3304B, 3306, 3306B, CB-534, D250E, D250E II, D25C, D300B, D300E, D300E II, D30C, D350C, D35C, R1300
1673C, 3304, 3304B, 3306, 3306B, CB-534, D250E, D250E II, D25C, D300B, D300E, D300E II, D30C, D350C, D35C, R1300
7N6486
PULLEY
3304, 3306, 3306B
3304, 3306, 3306B