3N6128 PULLEY GP-CRANKSHAFT Caterpillar parts
3304, 3304B, 3306, 3306B, 3306C, G3304, G3304B, G3306, G3306B
Rating:
Alternative (cross code) number:
CA3N6128
3N-6128
3N6128
CA3N6128
3N-6128
3N6128
Weight: 25 pounds 11 kg.
GAS ENGINE, TRUCK ENGINE,
Compatible equipment models: 3N6128:
Information:
TYPE="TABLE" @@@-->
Personal injury or death can result from improper troubleshooting and repair procedures.The following troubleshooting and repair procedures should only be performed by qualified personnel familiar with this equipment.
Refer to Safety Section, "Generator Isolating for Maintenance" for information regarding the procedure to safely isolate the generator.If the insulation resistance values are less than the recommended values, one of the following drying procedures must be selected. This decision should be based on the following factors:
the size of the unit
the location of the unit
the equipment that is available
the experience of personnelNote: For more information on drying methods, refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".Remove the voltage regulator. Cover all of the inlet openings. Cover all of the discharge holes. Provide an opening at the top of the machine. This opening will allow moisture to evaporate. Preferably, this opening will be located at the fan end. Monitor the winding temperatures. DO NOT APPLY HEAT TOO RAPIDLY. Winding temperature should be raised gradually at a rate of 10 °C (50 °F) per hour up to 85 °C (185 °F). Measure insulation resistance in 1 hour intervals. Typically, the insulation resistance will slowly drop while the temperature is rising. The insulation resistance will then start to increase at a slow rate until the insulation resistance reaches a constant level. The following methods can be used for drying a generator:
Self-circulating air method
Oven method
Controlled current methodSelf-Circulating Air Method
Run the engine and disconnect the generator load. Running the engine will help circulate air. Operate the generator space heaters.Oven Method
Place the entire generator inside a forced air drying oven for 4 hours at 65 °C (149 °F).
Use a forced air type oven rather than a radiant type oven.Radiant type ovens can cause localized overheating.
Controlled Current Method
Table 1
Tools Needed
Part Number Description Qty
225-8266 Ammeter Tool Gp 1
External Power Source 1
Rheostat 1 Heat can be used in order to dry the generator windings. This heat can be created by allowing a controlled current to flow through the generator. No high voltages are generated during the following procedure. Therefore, insulation breakdown will not occur.
Illustration 1 g00669571
Generator Wiring Diagram
(CR1-CR6) Diodes
(CR7) Varistor
(L1) Exciter field (stator)
(L2) Exciter armature (rotor)
(L3) Main field (rotor)
(L4) Main armature (stator)
(L5) Pilot exciter armature
(PM) Permanent magnet
(RFA) Rotating field assembly
(CST) Customer supplied transformer
Make an external power source.
Refer to the above diagram. Disconnect "F1+" from the voltage regulator. Disconnect "F2-" from the voltage regulator. Disconnect the generator load. Connect the generator output leads "T0", "T1", "T2", and "T3". Install the clamp-on ammeter to generator output lead "T1". Note: When the line current is measured on multiple-lead units, measure the current in each conductor per phase. The currents can then be added.
Refer to the above diagram. Connect the rheostat. Adjust the rheostat to the maximum resistance value. Connect the external power source to wires "F1+" and "F2-".
Start the generator set. Run the generator set at idle speed.
Monitor the phase current. Gradually increase the engine RPM. Increase the engine RPM until one of the following conditions are met:
The rated
Personal injury or death can result from improper troubleshooting and repair procedures.The following troubleshooting and repair procedures should only be performed by qualified personnel familiar with this equipment.
Refer to Safety Section, "Generator Isolating for Maintenance" for information regarding the procedure to safely isolate the generator.If the insulation resistance values are less than the recommended values, one of the following drying procedures must be selected. This decision should be based on the following factors:
the size of the unit
the location of the unit
the equipment that is available
the experience of personnelNote: For more information on drying methods, refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".Remove the voltage regulator. Cover all of the inlet openings. Cover all of the discharge holes. Provide an opening at the top of the machine. This opening will allow moisture to evaporate. Preferably, this opening will be located at the fan end. Monitor the winding temperatures. DO NOT APPLY HEAT TOO RAPIDLY. Winding temperature should be raised gradually at a rate of 10 °C (50 °F) per hour up to 85 °C (185 °F). Measure insulation resistance in 1 hour intervals. Typically, the insulation resistance will slowly drop while the temperature is rising. The insulation resistance will then start to increase at a slow rate until the insulation resistance reaches a constant level. The following methods can be used for drying a generator:
Self-circulating air method
Oven method
Controlled current methodSelf-Circulating Air Method
Run the engine and disconnect the generator load. Running the engine will help circulate air. Operate the generator space heaters.Oven Method
Place the entire generator inside a forced air drying oven for 4 hours at 65 °C (149 °F).
Use a forced air type oven rather than a radiant type oven.Radiant type ovens can cause localized overheating.
Controlled Current Method
Table 1
Tools Needed
Part Number Description Qty
225-8266 Ammeter Tool Gp 1
External Power Source 1
Rheostat 1 Heat can be used in order to dry the generator windings. This heat can be created by allowing a controlled current to flow through the generator. No high voltages are generated during the following procedure. Therefore, insulation breakdown will not occur.
Illustration 1 g00669571
Generator Wiring Diagram
(CR1-CR6) Diodes
(CR7) Varistor
(L1) Exciter field (stator)
(L2) Exciter armature (rotor)
(L3) Main field (rotor)
(L4) Main armature (stator)
(L5) Pilot exciter armature
(PM) Permanent magnet
(RFA) Rotating field assembly
(CST) Customer supplied transformer
Make an external power source.
Refer to the above diagram. Disconnect "F1+" from the voltage regulator. Disconnect "F2-" from the voltage regulator. Disconnect the generator load. Connect the generator output leads "T0", "T1", "T2", and "T3". Install the clamp-on ammeter to generator output lead "T1". Note: When the line current is measured on multiple-lead units, measure the current in each conductor per phase. The currents can then be added.
Refer to the above diagram. Connect the rheostat. Adjust the rheostat to the maximum resistance value. Connect the external power source to wires "F1+" and "F2-".
Start the generator set. Run the generator set at idle speed.
Monitor the phase current. Gradually increase the engine RPM. Increase the engine RPM until one of the following conditions are met:
The rated
Caterpillar SIS machinery equipment:
Caterpillar SIS
3304 INDUSTRIAL ENGINE 02B09537-17736 »
3N-6128
PULLEY GP-CRANKSHAFT
3304 INDUSTRIAL ENGINE 04B14449-26768 »
3N-6128
PULLEY GP-CRANKSHAFT
3304 MARINE ENGINE 05B02057-UP »
3N-6128
PULLEY GP-CRANKSHAFT
3306 INDUSTRIAL ENGINE 66D26832-49918 »
3N-6128
PULLEY GP-CRANKSHAFT
3306 MARINE ENGINE 67D02422-UP »
3N-6128
PULLEY GP-CRANKSHAFT
G3306 ENGINE 07Y00001-04278 »
3N-6128
PULLEY GP-CRANKSHAFT
G3304 ENGINE 37Y00001-UP »
3N-6128
PULLEY GP-CRANKSHAFT
3304 Industrial Engine 10E00300-UP »
3N-6128
PULLEY GP-CRANKSHAFT
3304 Marine Engine 13E00300-UP »
3N-6128
PULLEY GP-CRANKSHAFT
3306 Generator Set 85Z00001-03763 »
3N-6128
PULLEY GP-CRANKSHAFT
3306 Marine Engine 84Z00001-UP »
3N-6128
PULLEY GP-CRANKSHAFT
3304 GENERATOR SET ENGINE 83Z00001-03095 »
3N-6128
PULLEY GP-CRANKSHAFT
3306 INDUSTRIAL ENGINE 64Z00001-05380 »
3N-6128
PULLEY GP-CRANKSHAFT
3306B Industrial Engine 7JB00001-UP »
3N-6128
PULLEY GP-CRANKSHAFT
3306 Industrial Engine 66D49919-UP »
3N-6128
PULLEY GP-CRANKSHAFT
3306 Industrial Engine 64Z05381-UP »
3N-6128
PULLEY GP-CRANKSHAFT
3306 Generator Set 85Z03764-UP »
3N-6128
PULLEY GP-CRANKSHAFT
3304 Industrial Engine 02B17737-UP »
3N-6128
PULLEY GP-CRANKSHAFT
3304B Generator Set 83Z03096-UP »
3N-6128
PULLEY GP-CRANKSHAFT
3306C Truck Engine 9TL00001-UP »
3N-6128
PULLEY GP-CRANKSHAFT
3304 Industrial Engine 04B26769-UP »
3N-6128
PULLEY GP-CRANKSHAFT
3304B Marine Engine 8XL00001-UP »
3N-6128
PULLEY GP-CRANKSHAFT
G3306 ENGINE 07Y04279-UP »
3N-6128
PULLEY GP-CRANKSHAFT
3304B Marine Auxiliary & Generator Set Engine 1NS00001-UP POWERED BY 3304B Engine »
3N-6128
PULLEY GP-CRANKSHAFT
3306B Marine Auxiliary & Generator Set Engine 1RS00001-UP »
3N-6128
PULLEY GP-CRANKSHAFT
3304B Marine Auxiliary & Generator Set 1PS00001-UP »
3N-6128
PULLEY GP-CRANKSHAFT
3306B Generator Set 9NR00001-UP »
3N-6128
PULLEY GP-CRANKSHAFT
3306B Industrial Engine 5GZ00001-UP »
3N-6128
PULLEY GP-CRANKSHAFT
G3306 Generator Set CNR00001-UP »
3N-6128
PULLEY GP-CRANKSHAFT
G3306 Generator Set JCA00001-UP »
3N-6128
PULLEY GP-CRANKSHAFT
G3306 Gas Engine G6X00001-UP »
3N-6128
PULLEY GP-CRANKSHAFT
G3304 Gas Engine N4F00001-UP »
3N-6128
PULLEY GP-CRANKSHAFT
G3304B Gas Engine A4E00001-UP »
3N-6128
PULLEY GP-CRANKSHAFT
G3306B Gas Engine R6S00001-UP »
3N-6128
PULLEY GP-CRANKSHAFT
G3304B Gas Engine S4E00001-UP »
3N-6128
PULLEY GP-CRANKSHAFT
G3306B Gas Engine S6E00001-UP »
3N-6128
PULLEY GP-CRANKSHAFT
G333C OR 3306 ENGINE 68D00001-UP »
3N-6128
PULLEY GP-CRANKSHAFT
3304 ENGINE 02B04364-05271 »
3N-6128
PULLEY GP-CRANKSHAFT
3306 MARINE ENGINE 67D01103-01369 »
3N-6128
PULLEY GP-CRANKSHAFT
3304 MARINE ENGINE 05B01197-01386 »
3N-6128
PULLEY GP-CRANKSHAFT
3304 ENGINE 04B06032-07793 »
3N-6128
PULLEY GP-CRANKSHAFT
3306 ENGINE 66D08891-12369 »
3N-6128
PULLEY GP-CRANKSHAFT
3304 MARINE ENGINE 05B01387-02056 »
3N-6128
PULLEY GP-CRANKSHAFT
3304 INDUSTRIAL ENGINE 02B05272-09536 »
3N-6128
PULLEY GP-CRANKSHAFT
3304 INDUSTRIAL ENGINE 04B07794-14448 »
3N-6128
PULLEY GP-CRANKSHAFT
3306 INDUSTRIAL ENGINE 66D12370-26831 »
3N-6128
PULLEY GP-CRANKSHAFT
3306 MARINE ENGINE 67D01370-02421 »
3N-6128
PULLEY GP-CRANKSHAFT
Caterpillar parts catalog:
Parts pulley Caterpillar catalog:
7C3729
PULLEY-ALTERNATOR
205B, 214B, 3114, 3116, 3126, 3306, 3306B, 910E, 918F, 924F, 928F, 938F, 938G, AP-1000B, AP-1055B, AP-900B, BG-2455C, BG-245C, CB-434, CB-634, CB-634C, CP-563, CS-531, CS-531C, CS-533, CS-533C, CS-563...
205B, 214B, 3114, 3116, 3126, 3306, 3306B, 910E, 918F, 924F, 928F, 938F, 938G, AP-1000B, AP-1055B, AP-900B, BG-2455C, BG-245C, CB-434, CB-634, CB-634C, CP-563, CS-531, CS-531C, CS-533, CS-533C, CS-563...
8L8867
PULLEY
3116, 3126, 3304, 3304B, 3306, 3306B, 330B L, 637D, CB-534, D250B, D250E, D250E II, D25C, D25D, D300B, D300D, D300E, D300E II, D30C, D350C, D35C, G3304B, G3306B
3116, 3126, 3304, 3304B, 3306, 3306B, 330B L, 637D, CB-534, D250B, D250E, D250E II, D25C, D25D, D300B, D300D, D300E, D300E II, D30C, D350C, D35C, G3304B, G3306B
7W5692
PULLEY-CRANKSHAFT
3304, 3304B, 3306, 3306B, 3306C, CB-534, D250E, D250E II, D300E, D300E II, G3304, G3304B, G3306, G3306B
3304, 3304B, 3306, 3306B, 3306C, CB-534, D250E, D250E II, D300E, D300E II, G3304, G3304B, G3306, G3306B
4N4679
PULLEY-FAN DRIVE
3304, 3304B, 3306, 3306B, D250B, G3304, G3304B, G3306, G3306B
3304, 3304B, 3306, 3306B, D250B, G3304, G3304B, G3306, G3306B
8L4529
PULLEY-ALTERNATOR
3304, 3304B, 3306, 3306B, G3304, G3304B, G3306, G3306B
3304, 3304B, 3306, 3306B, G3304, G3304B, G3306, G3306B
7L0412
PULLEY
3304, 3306, G3306
3304, 3306, G3306
8L5435
PULLEY
3304
3304
8L5436
PULLEY
3304
3304
8L4530
PULLEY
3304, 3306
3304, 3306
7L0200
PULLEY
3304
3304
3607345
PULLEY GP-CRANKSHAFT
420E, 430E, C4.4, CB-54, CB-64, CP-44, CS-44, CS-54, D3K XL, D4K XL, D5K LGP
420E, 430E, C4.4, CB-54, CB-64, CP-44, CS-44, CS-54, D3K XL, D4K XL, D5K LGP
1703769
PULLEY GP-UPPER
PM-565B
PM-565B
6A9606
PULLEY GP
215
215
2964738
PULLEY AS-IDLER
311D LRR, 312D, 312D L, 314D CR, 314D LCR, 315D L, 318D L, 319D, 319D L, 319D LN
311D LRR, 312D, 312D L, 314D CR, 314D LCR, 315D L, 318D L, 319D, 319D L, 319D LN
2108602
PULLEY GP-AUXILIARY DRIVE
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, G3508, G3512, G3516, PM3508, PM3512, PM3516
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, G3508, G3512, G3516, PM3508, PM3512, PM3516
2542205
PULLEY GP-FAN DRIVE
3508, 3508B, 3512, 3512B, 3516, 3516B
3508, 3508B, 3512, 3512B, 3516, 3516B
2175553
PULLEY GP
305.5, 306, 307D, 308C
305.5, 306, 307D, 308C
3N5626
PULLEY GP-FAN DRIVE
3304, 3304B, 3306, 3306B, D250B, D353C, G3304, G3304B, G3306, G3306B
3304, 3304B, 3306, 3306B, D250B, D353C, G3304, G3304B, G3306, G3306B
7N8041
PULLEY GP-AUXILIARY DRIVE
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, G3508, G3512, G3516, PM3508, PM3512, PM3516, TH48-E80
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, G3508, G3512, G3516, PM3508, PM3512, PM3516, TH48-E80
3607347
PULLEY GP-CRANKSHAFT
416E, 420F, 422E, 428E, 428F, 430F, 432E, 432F, 434E, 434F, 442E, 444E, 444F, AP-300D, C4.4
416E, 420F, 422E, 428E, 428F, 430F, 432E, 432F, 434E, 434F, 442E, 444E, 444F, AP-300D, C4.4
7N1148
PULLEY GP-CRANKSHAFT
814B, 815B, 816B, 950B, 950B/950E, 963, 966D
814B, 815B, 816B, 950B, 950B/950E, 963, 966D
3013396
PULLEY GP-CRANKSHAFT
236B3, 242B3, 246C, 252B3, 256C, 257B3, 259B3, 262C, 262C2, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 906, 906H, 907H, 908, 908H, C3.4
236B3, 242B3, 246C, 252B3, 256C, 257B3, 259B3, 262C, 262C2, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 906, 906H, 907H, 908, 908H, C3.4