8N3304 PULLEY-TIGHTENER Caterpillar parts
589, 651E, 657E, 768C, 769C, D8L, D9L, D9N
Rating:
Alternative (cross code) number:
CA8N3304
8N-3304
8N3304
CA8N3304
8N-3304
8N3304
Weight: 10 pounds 4 kg.
Information:
DIAMETER OVER PINS
157.98
mm
GROOVE WIDTH
15.88
mm
NUMBER OF GROOVES
3
PIPELAYER, WHEEL TRACTOR,
Related part:
8N3304
PULLEY-TTNR-YM
4194708
CL
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 8N3304:
Information:
"PTO Configuration"
The "PTO Configuration" parameter determines the features that are available and the input signals that are used for dedicated PTO applications. If this parameter is programmed to "Off", the Engine Control Module (ECM) does not use the following configurations for the PTO. In order for the ECM to utilize the remaining parameters for the PTO configuration, a PTO on/off circuit must be connected to an appropriate input of the ECM.If the "PTO Configuration" parameter is programmed to "Cab Switches", the ECM will use the signals from the following two cab switches for PTO and cruise control:
J1/P1-35 PTO set switch
J1/P1-44 PTO resume switchIf the "PTO Configuration" parameter is programmed to "Remote Switches", the ECM will monitor the inputs that have been programmed for the remote control switches. All cab switches that are used for PTO control will be ignored when the PTO on/off circuit is on.If the "PTO Configuration" parameter is programmed to "Remote Throttle", the ECM will monitor J1/P1-68 Input #8 for the remote throttle input. The ECM will monitor the inputs that have been programmed for the remote control switches. All cab switches for the PTO control will be ignored when the PTO on/off circuit is on.
Table 1
Default Alternative
Off Cab Switches
Remote Switches
Remote Throttle "PTO Top Engine Limit"
The "PTO Top Engine Limit" is the top engine limit that is available during PTO operation.Note: The "PTO Configuration" parameter must be programmed to "Cab Switches", to "Remote Switches", or to "Remote Throttle" before this parameter can be programmed.
Table 2
Default Minimum Maximum
TEL rpm 700 TEL rpm "PTO Engine RPM Set Speed"
The "PTO Engine RPM Set Speed" parameter defines a preset value for the engine speed during PTO operation. The engine will proceed to this speed when the PTO on/off circuit is turned on or after the PTO set switch is actuated one time.The "PTO Configuration" parameter must be programmed to "Cab Switches" or to "Remote Switches" for this parameter to be enabled.Consider the following operational conditions during the setup of this parameter:
This parameter must be programmed higher than the programmed low idle of the engine.
If the "PTO to Set Speed" is programmed to a higher value than the "PTO Top Engine Limit", the set speed will be limited by the lower "PTO Top Engine Limit".
In order for the PTO to operate at one rpm set speed above the engine's low idle, program the "PTO Top Engine Limit" to the same rpm as the "PTO Engine RPM Set Speed".
In order for the PTO to operate at two rpm set speeds above the engine's low idle, program this parameter to some intermediate value between the low idle setting and the "PTO Top Engine Limit".To operate the PTO in the above example, place the PTO on/off switch to the ON position. Toggle the set switch once in order to cause the rpm to advance to the "PTO Engine RPM Set Speed". Toggle the set switch again in order to increase the engine rpm to the "PTO Top Engine Limit". Toggling the resume switch
The "PTO Configuration" parameter determines the features that are available and the input signals that are used for dedicated PTO applications. If this parameter is programmed to "Off", the Engine Control Module (ECM) does not use the following configurations for the PTO. In order for the ECM to utilize the remaining parameters for the PTO configuration, a PTO on/off circuit must be connected to an appropriate input of the ECM.If the "PTO Configuration" parameter is programmed to "Cab Switches", the ECM will use the signals from the following two cab switches for PTO and cruise control:
J1/P1-35 PTO set switch
J1/P1-44 PTO resume switchIf the "PTO Configuration" parameter is programmed to "Remote Switches", the ECM will monitor the inputs that have been programmed for the remote control switches. All cab switches that are used for PTO control will be ignored when the PTO on/off circuit is on.If the "PTO Configuration" parameter is programmed to "Remote Throttle", the ECM will monitor J1/P1-68 Input #8 for the remote throttle input. The ECM will monitor the inputs that have been programmed for the remote control switches. All cab switches for the PTO control will be ignored when the PTO on/off circuit is on.
Table 1
Default Alternative
Off Cab Switches
Remote Switches
Remote Throttle "PTO Top Engine Limit"
The "PTO Top Engine Limit" is the top engine limit that is available during PTO operation.Note: The "PTO Configuration" parameter must be programmed to "Cab Switches", to "Remote Switches", or to "Remote Throttle" before this parameter can be programmed.
Table 2
Default Minimum Maximum
TEL rpm 700 TEL rpm "PTO Engine RPM Set Speed"
The "PTO Engine RPM Set Speed" parameter defines a preset value for the engine speed during PTO operation. The engine will proceed to this speed when the PTO on/off circuit is turned on or after the PTO set switch is actuated one time.The "PTO Configuration" parameter must be programmed to "Cab Switches" or to "Remote Switches" for this parameter to be enabled.Consider the following operational conditions during the setup of this parameter:
This parameter must be programmed higher than the programmed low idle of the engine.
If the "PTO to Set Speed" is programmed to a higher value than the "PTO Top Engine Limit", the set speed will be limited by the lower "PTO Top Engine Limit".
In order for the PTO to operate at one rpm set speed above the engine's low idle, program the "PTO Top Engine Limit" to the same rpm as the "PTO Engine RPM Set Speed".
In order for the PTO to operate at two rpm set speeds above the engine's low idle, program this parameter to some intermediate value between the low idle setting and the "PTO Top Engine Limit".To operate the PTO in the above example, place the PTO on/off switch to the ON position. Toggle the set switch once in order to cause the rpm to advance to the "PTO Engine RPM Set Speed". Toggle the set switch again in order to increase the engine rpm to the "PTO Top Engine Limit". Toggling the resume switch
Caterpillar parts catalog:
Parts pulley Caterpillar catalog:
2W8494
PULLEY-ALTERNATOR
3126B, 3176B, 3176C, 3196, 572R, 621E, 627E, 65, 65C, 65E, 70C, 75, 75C, 75D, 75E, 814B, 814F, 815B, 815F, 816F, 85C, 85D, 85E, 95E, 966D, 966F, 966F II, 970F, 972G, 973, 973C, C-10, C-12, C-9, C11, C...
3126B, 3176B, 3176C, 3196, 572R, 621E, 627E, 65, 65C, 65E, 70C, 75, 75C, 75D, 75E, 814B, 814F, 815B, 815F, 816F, 85C, 85D, 85E, 95E, 966D, 966F, 966F II, 970F, 972G, 973, 973C, C-10, C-12, C-9, C11, C...
7C3938
PULLEY-ALTERNATOR
3114, 3116, 3126, 3126B, 613C II, 950F, 953B, 953C, 963B, 963C, D8L, D9N, D9R
3114, 3116, 3126, 3126B, 613C II, 950F, 953B, 953C, 963B, 963C, D8L, D9N, D9R
1337023
PULLEY AS-IDLER
120M 2, 3176C, 3196, 3406E, 345B, 345B II, 345B II MH, 345B L, 365B, 365B II, 365B L, 365C, 365C L, 365C L MH, 374D L, 385B, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L, 5090B, 621B, 621G, 623G, 62...
120M 2, 3176C, 3196, 3406E, 345B, 345B II, 345B II MH, 345B L, 365B, 365B II, 365B L, 365C, 365C L, 365C L MH, 374D L, 385B, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L, 5090B, 621B, 621G, 623G, 62...
4N8225
PULLEY-ALTERNATOR
245, 245B, 245D, 3116, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412E, 375, 375 L, 5080, 583R, 587R, 589, 621, 621B, 621E, 621F, 621G, 623E, 623F, 623G, 627E, 627F, 627G, 631...
245, 245B, 245D, 3116, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412E, 375, 375 L, 5080, 583R, 587R, 589, 621, 621B, 621E, 621F, 621G, 623E, 623F, 623G, 627E, 627F, 627G, 631...
4N4534
PULLEY-CRANKSHAFT
245, 375, 375 L, 5080, 578, 583R, 587R, 621B, 621E, 621F, 621G, 623E, 623F, 623G, 627E, 627F, 627G, 651B, 826C, 980C, 980F, 983B, D8N, D8R, D8R II, D9N
245, 375, 375 L, 5080, 578, 583R, 587R, 621B, 621E, 621F, 621G, 623E, 623F, 623G, 627E, 627F, 627G, 651B, 826C, 980C, 980F, 983B, D8N, D8R, D8R II, D9N
7N1275
PULLEY-FAN DRIVE
578, 583R, 587R, 589, 631E, 633E II, 637D, 637E, 651E, 657E, 69D, 768C, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 988B, D8L, D8N, D9L, D9N
578, 583R, 587R, 589, 631E, 633E II, 637D, 637E, 651E, 657E, 69D, 768C, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 988B, D8L, D8N, D9L, D9N
4W0839
PULLEY-CRANKSHAFT
589, D8L
589, D8L
6N3641
PULLEY-TIGHTENER
631D, 631E, 631G, 633E II, 637D, 637E, 637G, 639D, 651E, 657E, 69D, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775B, 775D, 775E, 775F, 775G, 775G LRC, 775G OEM, 834B, 98...
631D, 631E, 631G, 633E II, 637D, 637E, 637G, 639D, 651E, 657E, 69D, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775B, 775D, 775E, 775F, 775G, 775G LRC, 775G OEM, 834B, 98...
6N5300
PULLEY-CRANKSHAFT
657E, 69D, 768C, 769C, 769D, 771C, 771D, 834B, 988B
657E, 69D, 768C, 769C, 769D, 771C, 771D, 834B, 988B
6N1186
PULLEY
24H, 5110B, 992, 992C, 992D, D10N, D10R, D9L
24H, 5110B, 992, 992C, 992D, D10N, D10R, D9L
7W6173
PULLEY-CRANKSHAFT
D10N, D9L
D10N, D9L
7W5684
PULLEY-CRANKSHAFT
814B, 815B, 950B, 973
814B, 815B, 950B, 973
3065754
PULLEY AS
953D
953D
3065752
PULLEY AS
953D
953D
2529662
PULLEY
D6R II
D6R II
2436491
PULLEY-FAN
D6R II
D6R II
2W6682
PULLEY-CRANKSHAFT
966D, D6H, D6H XL, D6H XR
966D, D6H, D6H XL, D6H XR
2W1720
PULLEY-ALTERNATOR
517, 527, D4H, D4H XL, D4HTSK III, D5H, D5H XL, D5HTSK II
517, 527, D4H, D4H XL, D4HTSK III, D5H, D5H XL, D5HTSK II
7C6628
PULLEY-ALTERNATOR
578, 966F II, 966G, 970F, 972G, D8N
578, 966F II, 966G, 970F, 972G, D8N
4W0839
PULLEY-CRANKSHAFT
589, D8L
589, D8L
7N1275
PULLEY-FAN DRIVE
578, 583R, 587R, 589, 631E, 633E II, 637D, 637E, 651E, 657E, 69D, 768C, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 988B, D8L, D8N, D9L, D9N
578, 583R, 587R, 589, 631E, 633E II, 637D, 637E, 651E, 657E, 69D, 768C, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 988B, D8L, D8N, D9L, D9N
1104165
PULLEY-CRANKSHAFT
589, D9N
589, D9N