Information:
Note: Obtaining a Coolant Sample (Level 1) is optional if the cooling system is filled with Cat ELC (Extended Life Coolant). Cooling systems filled with Cat ELC should have a Coolant Sample (Level 2) that is obtained at the recommended interval as stated in the maintenance interval schedule.Note: Obtain a Coolant Sample (Level 1) if the cooling system is filled with any other coolant instead of Cat ELC including the following coolants:
Commercial long life coolants that meet the Caterpillar Engine Coolant Specification -1 (Caterpillar EC-1)
Cat DEAC (Diesel Engine Antifreeze/Coolant)
Commercial heavy-duty coolant/antifreeze
Table 1
Recommended Interval
Type of Coolant Level 1 Level 2
Cat DEAC Every 250 service hours Every year(1)
Conventional heavy duty-coolant
Commercial coolant that meets the requirements of the Caterpillar EC-1 standard
Cat ELC or conventional EC-1 coolant Optional Every year(1)
(1) The Level 2 Coolant Analysis should be performed sooner if a problem is suspected or identified.
Always use a designated pump for oil sampling, and use a separate designated pump for coolant sampling. Using the same pump for both types of samples may contaminate the samples that are being drawn. This contaminate may cause a false analysis and an incorrect interpretation that could lead to concerns by both dealers and customers.
Note: Level 1 results may indicate a need for Level 2 Analysis.Obtain the sample of the coolant as close as possible to the recommended sampling interval. In order to receive the full effect of S O S analysis, establish a consistent trend of data. In order to establish a pertinent history of data, perform consistent samplings that are evenly spaced. Supplies for collecting samples can be obtained from your Caterpillar dealer.Use the following guidelines for proper sampling of the coolant:
Complete the information on the label for the sampling bottle before you begin to take the samples.
Keep the unused sampling bottles stored in plastic bags.
Obtain coolant samples directly from the coolant sample port. You should not obtain the samples from any other location.
Keep the lids on empty sampling bottles until you are ready to collect the sample.
Place the sample in the mailing tube immediately after obtaining the sample in order to avoid contamination.
Never collect samples from expansion bottles.
Never collect samples from the drain for a system.Submit the sample for Level 1 analysis.For additional information about coolant analysis, see this Operation and Maintenance Manual, "Refill Capacities and Recommendations" or consult your Caterpillar dealer.
Commercial long life coolants that meet the Caterpillar Engine Coolant Specification -1 (Caterpillar EC-1)
Cat DEAC (Diesel Engine Antifreeze/Coolant)
Commercial heavy-duty coolant/antifreeze
Table 1
Recommended Interval
Type of Coolant Level 1 Level 2
Cat DEAC Every 250 service hours Every year(1)
Conventional heavy duty-coolant
Commercial coolant that meets the requirements of the Caterpillar EC-1 standard
Cat ELC or conventional EC-1 coolant Optional Every year(1)
(1) The Level 2 Coolant Analysis should be performed sooner if a problem is suspected or identified.
Always use a designated pump for oil sampling, and use a separate designated pump for coolant sampling. Using the same pump for both types of samples may contaminate the samples that are being drawn. This contaminate may cause a false analysis and an incorrect interpretation that could lead to concerns by both dealers and customers.
Note: Level 1 results may indicate a need for Level 2 Analysis.Obtain the sample of the coolant as close as possible to the recommended sampling interval. In order to receive the full effect of S O S analysis, establish a consistent trend of data. In order to establish a pertinent history of data, perform consistent samplings that are evenly spaced. Supplies for collecting samples can be obtained from your Caterpillar dealer.Use the following guidelines for proper sampling of the coolant:
Complete the information on the label for the sampling bottle before you begin to take the samples.
Keep the unused sampling bottles stored in plastic bags.
Obtain coolant samples directly from the coolant sample port. You should not obtain the samples from any other location.
Keep the lids on empty sampling bottles until you are ready to collect the sample.
Place the sample in the mailing tube immediately after obtaining the sample in order to avoid contamination.
Never collect samples from expansion bottles.
Never collect samples from the drain for a system.Submit the sample for Level 1 analysis.For additional information about coolant analysis, see this Operation and Maintenance Manual, "Refill Capacities and Recommendations" or consult your Caterpillar dealer.
Parts pump Caterpillar catalog:
10R9119
PUMP GP-GR A
Caterpillar
Caterpillar
0R1072
PUMP GP-HYD
Caterpillar
Caterpillar
0R8354
PUMP GP-WATER
Caterpillar
Caterpillar
0R2856
PUMP GP-WATER
Caterpillar
Caterpillar
0R7896
PUMP GP-AUX -S
Caterpillar
Caterpillar
0R2825
PUMP GP-WATER
Caterpillar
Caterpillar
10R9121
PUMP GP-GR B
Caterpillar
Caterpillar
0R8373
PUMP GP-HYD
Caterpillar
Caterpillar
0R8372
PUMP GP-HYD
Caterpillar
Caterpillar
0R8101
PUMP GP-HYD
Caterpillar
Caterpillar
10R9120
PUMP GP-GR A
Caterpillar
Caterpillar
0R4602
PUMP GP-HYD
Caterpillar
Caterpillar