10R7053 PUMP GP-UNIT INJECTOR HYD Caterpillar parts
3126B, 3126E
Rating:
Alternative (cross code) number:
CA10R7053
10R-7053
10R7053
CA10R7053
10R-7053
10R7053
Weight: 11 pounds 5 kg.
TRUCK ENGINE,
Related part:
1355459
PUMP GP-HYD
10R7053
R
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
DUCRES Compatible With Caterpillar CAT 3126 3126B Engine 322C 325C Excavator 938G 950G 962G 953C 963C D6N D5N 10R-2995 10R-7053 Fuel Injection Pump
DUCRES Part Name: 10R-2995 10R-7053 Fuel Injection Pump || Part Number: 10R-2995 10R-7053 || Compatible with Caterpillar CAT 3126 3126B Engine 322C 325C Excavator 938G 950G 962G 953C 963C D6N D5N || Package includes: 1 PC Fuel Injection Pump || Please be sure to compare carefully with photos and check part number before buying item.If you can't confirm your engine model or part number. Please leave us a message, we will help you confirm that the purchased product is what you need
DUCRES Part Name: 10R-2995 10R-7053 Fuel Injection Pump || Part Number: 10R-2995 10R-7053 || Compatible with Caterpillar CAT 3126 3126B Engine 322C 325C Excavator 938G 950G 962G 953C 963C D6N D5N || Package includes: 1 PC Fuel Injection Pump || Please be sure to compare carefully with photos and check part number before buying item.If you can't confirm your engine model or part number. Please leave us a message, we will help you confirm that the purchased product is what you need
Fuel Pump 180-7341 162-9608 162-9612 134-0467 10R-7053
Generic Fuel Pump 180-7341 162-9608 162-9612 134-0467 10R-7053
Generic Fuel Pump 180-7341 162-9608 162-9612 134-0467 10R-7053
Mechanical engine parts 3126E fuel Injector pump 134-0467 10R-7053 Compatible With caterpillar truck
UJMLQVPXR Smooth operation reduces engine vibration and noise. || Responsive fuel supply enhances excavator performance. || Optimized fuel supply efficiency reduces fuel consumption. || Fine fuel atomization, complete combustion, and strong power. || Adjustable fuel delivery adapts to different working conditions for stable operation.
UJMLQVPXR Smooth operation reduces engine vibration and noise. || Responsive fuel supply enhances excavator performance. || Optimized fuel supply efficiency reduces fuel consumption. || Fine fuel atomization, complete combustion, and strong power. || Adjustable fuel delivery adapts to different working conditions for stable operation.
This part in 4 request:
Show.
This information for suppliers only!
2022-03-28
2022-02-27
2021-11-10
2018-02-08
Information:
You must read and understand the warnings and instructions contained in the Safety section of this manual before performing any operation or maintenance procedures.Space Heaters
Space Heaters are recommended for SR4 generators that are installed in high humid conditions.The SR4 generator can operate in high humidity conditions without problems. However, problems can occur when the generator is idle and the surrounding air is warmer than the generator. Moisture can form on the windings and result in poor performance and even result in damage to the windings. Whenever the generator is not in use, insure that the space heaters are in operation.Whenever the generator is operating, insure the space heaters are disconnected.An external source of either 115 or 230 volts AC (200V at 50 Hz) is required to operate the space heaters. Space Heater Connection to External Source H1, H2, H3, H4 Terminal Strip Terminals.If 115 VAC source is available, connect both heaters in parallel across the source (L1-L2). If 230 VAC source is available, connect both heaters in series across the source (L1-L2).Recommended Periodic Resistance Checks
Use a megohmmeter (megger) to check generator main stator winding insulation resistance periodically. The frequency of the insulation resistance test is determined by the generator's environment and by previous megohmmeter test indicators. Test the main stator windings with a megohmmeter (megger) in the following situations:1. Before initial startup of generator set.2. After generator storage.3. Every three months if generator is operating in a humid environment or is not protected from the elements by an enclosed area.4. Every six months if the generator is installed in an enclosed area with relatively low humidity and minimal temperature variations.5. If generator has not been run under load for three months or more.6. Test every week and use space heaters if the generator is exposed to a sea water environment or if the surrounding conditions are very humid (relative humidity above 75%) or if a recent test reading was less than three megohms. In applications where salt and high humidity are present, space heaters must be operated whenever the generator is not operating under load. This is the only way to maintain megohmmeter test readings above one megohm.The insulation resistance check is described in Special Instruction SEHS9124. A reading of one megohm or less indicates that the winding has absorbed too much moisture.This is a guideline only. It may be necessary to megger more frequently if the environment is extremely humid, salty or if the last megger test was close to one megohm.Clean and Inspect
Before working inside the generator, make sure that the starter motor can not be activated by any automatic or manual signal.When the engine-generator is operating, voltages up to 600V are present in these areas near or on the regulator:1. the regulator terminal strip.2. the excitation transformer terminal strip (self-excited generator only).Do not short these terminals to ground with any part of the body or any conductive material. Loss of life or injury could result from electrical shock or injury from molten metal.An electrical
Space Heaters are recommended for SR4 generators that are installed in high humid conditions.The SR4 generator can operate in high humidity conditions without problems. However, problems can occur when the generator is idle and the surrounding air is warmer than the generator. Moisture can form on the windings and result in poor performance and even result in damage to the windings. Whenever the generator is not in use, insure that the space heaters are in operation.Whenever the generator is operating, insure the space heaters are disconnected.An external source of either 115 or 230 volts AC (200V at 50 Hz) is required to operate the space heaters. Space Heater Connection to External Source H1, H2, H3, H4 Terminal Strip Terminals.If 115 VAC source is available, connect both heaters in parallel across the source (L1-L2). If 230 VAC source is available, connect both heaters in series across the source (L1-L2).Recommended Periodic Resistance Checks
Use a megohmmeter (megger) to check generator main stator winding insulation resistance periodically. The frequency of the insulation resistance test is determined by the generator's environment and by previous megohmmeter test indicators. Test the main stator windings with a megohmmeter (megger) in the following situations:1. Before initial startup of generator set.2. After generator storage.3. Every three months if generator is operating in a humid environment or is not protected from the elements by an enclosed area.4. Every six months if the generator is installed in an enclosed area with relatively low humidity and minimal temperature variations.5. If generator has not been run under load for three months or more.6. Test every week and use space heaters if the generator is exposed to a sea water environment or if the surrounding conditions are very humid (relative humidity above 75%) or if a recent test reading was less than three megohms. In applications where salt and high humidity are present, space heaters must be operated whenever the generator is not operating under load. This is the only way to maintain megohmmeter test readings above one megohm.The insulation resistance check is described in Special Instruction SEHS9124. A reading of one megohm or less indicates that the winding has absorbed too much moisture.This is a guideline only. It may be necessary to megger more frequently if the environment is extremely humid, salty or if the last megger test was close to one megohm.Clean and Inspect
Before working inside the generator, make sure that the starter motor can not be activated by any automatic or manual signal.When the engine-generator is operating, voltages up to 600V are present in these areas near or on the regulator:1. the regulator terminal strip.2. the excitation transformer terminal strip (self-excited generator only).Do not short these terminals to ground with any part of the body or any conductive material. Loss of life or injury could result from electrical shock or injury from molten metal.An electrical
Caterpillar parts catalog:
Parts pump Caterpillar catalog:
7C4508
PUMP GP-WATER
205B, 206B, 211B, 212B, 213B, 214B, 224B, 3114, 3116, 3126, 3126B, 3126E, 320 L, 320B, 322, 322 FM L, 322 LN, 322B, 322B L, 322B LN, 325, 325 L, 325 LN, 325B, 325B L, 35, 446, 446B, 446D, 45, 525B, 53...
205B, 206B, 211B, 212B, 213B, 214B, 224B, 3114, 3116, 3126, 3126B, 3126E, 320 L, 320B, 322, 322 FM L, 322 LN, 322B, 322B L, 322B LN, 325, 325 L, 325 LN, 325B, 325B L, 35, 446, 446B, 446D, 45, 525B, 53...
3652134
PUMP GP-WATER
3126, 3126B, 3126E, C7
3126, 3126B, 3126E, C7
2001212
PUMP GP-WATER
3126B, 3126E, C7, C9, CX31-C9I, TH31-E61
3126B, 3126E, C7, C9, CX31-C9I, TH31-E61
2036097
PUMP GP-WATER
3126B, 3126E, C9
3126B, 3126E, C9
2278843
PUMP GP-WATER
3126E, C7
3126E, C7
1052508
PUMP AS-FUEL PRIMING
120G, 12G, 12H, 12H ES, 12H NA, 140H, 140H ES, 140H NA, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 163H, 163H NA, 16G, 16H, 16H NA, 214B, 235, 3114, 3116, 3126, 3126B, 3126E, 3176, 3176B, 3176C, 3196,...
120G, 12G, 12H, 12H ES, 12H NA, 140H, 140H ES, 140H NA, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 163H, 163H NA, 16G, 16H, 16H NA, 214B, 235, 3114, 3116, 3126, 3126B, 3126E, 3176, 3176B, 3176C, 3196,...
1375541
PUMP GP-FUEL PRIMING
120G, 12G, 130G, 140G, 140H, 143H, 14G, 14H, 160G, 160H, 163H, 1673C, 16H, 235B, 24H, 3116, 311C, 311D LRR, 3126, 3126B, 3126E, 312C, 312C L, 312D, 312D L, 313D, 314C, 314D CR, 314D LCR, 315C, 315D L,...
120G, 12G, 130G, 140G, 140H, 143H, 14G, 14H, 160G, 160H, 163H, 1673C, 16H, 235B, 24H, 3116, 311C, 311D LRR, 3126, 3126B, 3126E, 312C, 312C L, 312D, 312D L, 313D, 314C, 314D CR, 314D LCR, 315C, 315D L,...
1898777
PUMP GP-ENGINE OIL
120H, 120H ES, 120H NA, 120K, 120K 2, 12K, 12M, 135H, 135H NA, 140G, 140K, 140K 2, 140M, 160K, 30/30, 3116, 3126, 3126B, 3126E, 320B, 322B L, 322B LN, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L,...
120H, 120H ES, 120H NA, 120K, 120K 2, 12K, 12M, 135H, 135H NA, 140G, 140K, 140K 2, 140M, 160K, 30/30, 3116, 3126, 3126B, 3126E, 320B, 322B L, 322B LN, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L,...
1593139
PUMP AS-WATER
3116, 3126, 3126B, 3126E, 322C, 322C FM, 325C, 325C FM, 328D LCR, 329D L, 570B, 580B, 962G II, C7, M325C MH
3116, 3126, 3126B, 3126E, 322C, 322C FM, 325C, 325C FM, 328D LCR, 329D L, 570B, 580B, 962G II, C7, M325C MH
1593145
PUMP AS-WATER
3116, 3126, 3126B, 3126E, 950F, 950F II, 960F, C7
3116, 3126, 3126B, 3126E, 950F, 950F II, 960F, C7
3522142
PUMP AS-WATER
3116, 3126, 3126B, 3126E, C7
3116, 3126, 3126B, 3126E, C7
0R2733
PUMP GP-ENGINE OIL
3126B, 3126E, C7
3126B, 3126E, C7
3286098
PUMP GP-ENGINE OIL
3126B, 3126E
3126B, 3126E
0R2733
PUMP GP-ENGINE OIL
3126B, 3126E, C7
3126B, 3126E, C7
1554637
PUMP GP-STEERING
3116, 3126
3116, 3126
3522142
PUMP AS-WATER
3116, 3126, 3126B, 3126E, C7
3116, 3126, 3126B, 3126E, C7
1077752
PUMP AS-WATER
3126, 950F II, 960F
3126, 950F II, 960F
1593145
PUMP AS-WATER
3116, 3126, 3126B, 3126E, 950F, 950F II, 960F, C7
3116, 3126, 3126B, 3126E, 950F, 950F II, 960F, C7
10R0484
PUMP GP-WATER
583T, 621G, 623G, 627F, 627G, 657E, 824H, 825H, 826H, 980H, C-15, C-16, D8T, PL83
583T, 621G, 623G, 627F, 627G, 657E, 824H, 825H, 826H, 980H, C-15, C-16, D8T, PL83
2036096
PUMP AS-WATER
3126B, 3126E, C9
3126B, 3126E, C9
0R9439
PUMP GP-UNIT INJECTOR HYD
3126B, 3126E
3126B, 3126E
0R9438
PUMP GP-FUEL TRANSFER
3126B, 3126E
3126B, 3126E