TYPE="1" START="1">
Check for the proper version of the regulator.
Check the part number of the digital voltage regulator. Refer to the chart in Testing And Adjusting, "Troubleshooting". Check whether the digital voltage regulator is proper for the application.Expected Result: The digital voltage regulator is proper for the application.Results:
OK: Go to Step 2.
NOT OK: Install the proper digital voltage regulator. STOP.
Check the status of the display.
Stop the generator set.
Observe the display on the digital voltage regulator.Expected Result: The display should contain a number.Results:
OK: Proceed to Step 4.
NOT OK: No number is present on the display. Proceed to Step 3.
Check the DC voltage.
Check for proper DC voltage from terminal "B+" to "B-". The acceptable voltage range is 18 VDC to 32 VDC.Expected Result: The sufficient DC voltage is present.Results:
OK: The sufficient DC voltage is present. Remove the DC power wires from terminals "B+" and "B-" for 30 seconds. Reconnect the DC power wires to the "B+" and "B-" terminals. If the regulator display is still blank, the regulator is faulty. Then, the regulator needs to be replaced. If this condition has occured, verify that the correct burden resistor or rheostat is connected between the droop current transformer and the regulator. If no resistor is present, the regulator was destroyed because of high current on the CT input. Refer to Testing And Adjusting, "Wiring Diagrams". STOP.
NOT OK: The sufficient DC voltage is not present. Repair the supply voltage wiring, fuses and circuit breakers as necessary. STOP.
Verify the proper configuration of the parameters.Pay particular attention to parameters :01, :02, and :30.
If the rated voltage, parameter :01 is increased, the output voltage will increase.
If the sensing transformer ratio, parameter :02 is decreased, the output voltage will increase.
If the voltage droop, parameter :30 is increased, the output voltage will decrease as the generator output current increases. Try the default value.
If generator type is set incorrectly, the regulator may operate constantly in the under frequency curve. Check parameter :50 and compare actual frequency to verify.
If the current transformer is installed or wired incorrectly (reverse polarity) and voltage gain (parameter :15) is greater than zero, the output voltage will decrease as the generator output current increases. Reverse the wires on terminal 5 and terminal 6.
Display the number in parameters :92, :93, and :95 (if present). A display of "0000" indicates no faults. If a fault code is present, see System Operation, "Parameters".Expected Result: The problem has been resolved.Results:
OK: The problem has been resolved. STOP.
NOT OK: The problem has not been resolved. Proceed to Step 5.
Check the PM inputs.
Turn the engine off.
Check that all of the digital voltage regulator connections are tight and properly made per the appropriate wiring diagram.
Check PM fuses (connecting to terminals 26 and 30 of the digital voltage regulator).
Restart the engine.
Check the PM inputs (26, 28, and 30) of the digital voltage regulator. Measure the AC voltage between terminals 26 to 28, 28 to 30, and 26 to 30.
If the digital voltage regulator is connected as a self-excited regulator, check if the power transformers
Check for the proper version of the regulator.
Check the part number of the digital voltage regulator. Refer to the chart in Testing And Adjusting, "Troubleshooting". Check whether the digital voltage regulator is proper for the application.Expected Result: The digital voltage regulator is proper for the application.Results:
OK: Go to Step 2.
NOT OK: Install the proper digital voltage regulator. STOP.
Check the status of the display.
Stop the generator set.
Observe the display on the digital voltage regulator.Expected Result: The display should contain a number.Results:
OK: Proceed to Step 4.
NOT OK: No number is present on the display. Proceed to Step 3.
Check the DC voltage.
Check for proper DC voltage from terminal "B+" to "B-". The acceptable voltage range is 18 VDC to 32 VDC.Expected Result: The sufficient DC voltage is present.Results:
OK: The sufficient DC voltage is present. Remove the DC power wires from terminals "B+" and "B-" for 30 seconds. Reconnect the DC power wires to the "B+" and "B-" terminals. If the regulator display is still blank, the regulator is faulty. Then, the regulator needs to be replaced. If this condition has occured, verify that the correct burden resistor or rheostat is connected between the droop current transformer and the regulator. If no resistor is present, the regulator was destroyed because of high current on the CT input. Refer to Testing And Adjusting, "Wiring Diagrams". STOP.
NOT OK: The sufficient DC voltage is not present. Repair the supply voltage wiring, fuses and circuit breakers as necessary. STOP.
Verify the proper configuration of the parameters.Pay particular attention to parameters :01, :02, and :30.
If the rated voltage, parameter :01 is increased, the output voltage will increase.
If the sensing transformer ratio, parameter :02 is decreased, the output voltage will increase.
If the voltage droop, parameter :30 is increased, the output voltage will decrease as the generator output current increases. Try the default value.
If generator type is set incorrectly, the regulator may operate constantly in the under frequency curve. Check parameter :50 and compare actual frequency to verify.
If the current transformer is installed or wired incorrectly (reverse polarity) and voltage gain (parameter :15) is greater than zero, the output voltage will decrease as the generator output current increases. Reverse the wires on terminal 5 and terminal 6.
Display the number in parameters :92, :93, and :95 (if present). A display of "0000" indicates no faults. If a fault code is present, see System Operation, "Parameters".Expected Result: The problem has been resolved.Results:
OK: The problem has been resolved. STOP.
NOT OK: The problem has not been resolved. Proceed to Step 5.
Check the PM inputs.
Turn the engine off.
Check that all of the digital voltage regulator connections are tight and properly made per the appropriate wiring diagram.
Check PM fuses (connecting to terminals 26 and 30 of the digital voltage regulator).
Restart the engine.
Check the PM inputs (26, 28, and 30) of the digital voltage regulator. Measure the AC voltage between terminals 26 to 28, 28 to 30, and 26 to 30.
If the digital voltage regulator is connected as a self-excited regulator, check if the power transformers
Caterpillar SIS machinery equipment:
Caterpillar SIS
375 & 375 L Excavators 1JM00001-UP (MACHINE) POWERED BY 3406 Engine »
135-8865
PUMP GP-PISTON
375 and 375 L Excavators 6NK00001-UP (MACHINE) POWERED BY 3406 Engine »
135-8865
PUMP GP-PISTON
5080 Excavator 6XK00001-UP (MACHINE) POWERED BY 3406B Engine »
135-8865
PUMP GP-PISTON
5080 Excavator 8SL00001-UP (MACHINE) POWERED BY 3406B Engine »
135-8865
PUMP GP-PISTON
375, 375L TRACK-TYPE EXCAVATORS 6RL00001-UP (MACHINE) POWERED BY 3406 ENGINE »
135-8865
PUMP GP-PISTON
375, 375L TRACK-TYPE EXCAVATORS 6RL00081-UP (MACHINE) POWERED BY 3406 ENGINE »
135-8865
PUMP GP-PISTON
Caterpillar parts catalog:
Parts pump Caterpillar catalog:
1W1700
PUMP GP-FUEL TRANSFER
16G, 16H NA, 245, 245B, 245D, 3406B, 3406C, 375, 375 L, 5080, 578, 583R, 587R, 621E, 621F, 623E, 623F, 627E, 627F, 814B, 824C, 824G, 825C, 825G, 826C, 826G, 980C, 980F, 980F II, 980G, D350E, D35HP, D4...
16G, 16H NA, 245, 245B, 245D, 3406B, 3406C, 375, 375 L, 5080, 578, 583R, 587R, 621E, 621F, 623E, 623F, 627E, 627F, 814B, 824C, 824G, 825C, 825G, 826C, 826G, 980C, 980F, 980F II, 980G, D350E, D35HP, D4...
3520203
PUMP GP-WATER
16G, 16H NA, 3406B, 3406C, 375, 5080, 578, 583R, 587R, 621F, 623E, 623F, 627B, 627F, 814B, 824G, 825G, 826C, 826G, 980C, 980F, 980G, D350E, D400E, D8N, D8R, D8R II, G3406, HT400, PM-465, RM-250C, RM-3...
16G, 16H NA, 3406B, 3406C, 375, 5080, 578, 583R, 587R, 621F, 623E, 623F, 627B, 627F, 814B, 824G, 825G, 826C, 826G, 980C, 980F, 980G, D350E, D400E, D8N, D8R, D8R II, G3406, HT400, PM-465, RM-250C, RM-3...
1981508
PUMP GP-ENGINE OIL
3406B, 3406C, 3406E, 3408, 365C, 365C L, 365C L MH, 374D L, 374F L, 375, 375 L, 385B, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L, 390F L, 5080, 5090B, 583R, 587R, C-15, C-16, C15, C18, D8N, D8R, D...
3406B, 3406C, 3406E, 3408, 365C, 365C L, 365C L MH, 374D L, 374F L, 375, 375 L, 385B, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L, 390F L, 5080, 5090B, 583R, 587R, C-15, C-16, C15, C18, D8N, D8R, D...
1086633
PUMP GP-FUEL INJECTION
16G, 16H NA, 245D, 3406B, 3406C, 3408B, 3408C, 3412, 3412C, 375, 375 L, 5080, 578, 583R, 587R, 621F, 623E, 623F, 627B, 627F, 814B, 824C, 824G, 825C, 825G, 826C, 826G, 980C, 980F, 980F II, 980G, D350E,...
16G, 16H NA, 245D, 3406B, 3406C, 3408B, 3408C, 3412, 3412C, 375, 375 L, 5080, 578, 583R, 587R, 621F, 623E, 623F, 627B, 627F, 814B, 824C, 824G, 825C, 825G, 826C, 826G, 980C, 980F, 980F II, 980G, D350E,...
4P7681
PUMP GP-FUEL INJECTION
16G, 245B, 245D, 3406B, 3408B, 3412, 375, 375 L, 578, 621E, 621F, 623E, 627E, 627F, 824C, 824G, 825C, 825G, 826C, 826G, 980C, 980F, 980G, D40D, D8N, D8R II, RR-250, SS-250
16G, 245B, 245D, 3406B, 3408B, 3412, 375, 375 L, 578, 621E, 621F, 623E, 627E, 627F, 824C, 824G, 825C, 825G, 826C, 826G, 980C, 980F, 980G, D40D, D8N, D8R II, RR-250, SS-250
1025939
PUMP GP-WATER
16G, 16H NA, 245B, 245D, 3406, 3406B, 3406C, 375, 375 L, 5080, 578, 621E, 621F, 623E, 627E, 627F, 814B, 824C, 824G, 825C, 825G, 826C, 826G, 980C, 980F, 980F II, 980G, D350E, D400E, D40D, D8N, D8R, G34...
16G, 16H NA, 245B, 245D, 3406, 3406B, 3406C, 375, 375 L, 5080, 578, 621E, 621F, 623E, 627E, 627F, 814B, 824C, 824G, 825C, 825G, 826C, 826G, 980C, 980F, 980F II, 980G, D350E, D400E, D40D, D8N, D8R, G34...
2W4381
PUMP GP-FUEL TRANSFER
16G, 16H NA, 245, 245B, 245D, 3126, 3406B, 3406C, 375, 375 L, 5080, 578, 583R, 587R, 621E, 621F, 623E, 623F, 627E, 627F, 814B, 824C, 824G, 825C, 825G, 826C, 826G, 980C, 980F, 980F II, 980G, D350E, D35...
16G, 16H NA, 245, 245B, 245D, 3126, 3406B, 3406C, 375, 375 L, 5080, 578, 583R, 587R, 621E, 621F, 623E, 623F, 627E, 627F, 814B, 824C, 824G, 825C, 825G, 826C, 826G, 980C, 980F, 980F II, 980G, D350E, D35...
1341341
PUMP GP-WATER
16G, 16H NA, 245D, 3406, 3406B, 3406C, 375, 375 L, 5080, 578, 621E, 621F, 623E, 627F, 814B, 824C, 824G, 825C, 825G, 826C, 826G, 980C, 980F, 980F II, 980G, D350E, D400E, D40D, D8N, D8R, G3406, RR-250, ...
16G, 16H NA, 245D, 3406, 3406B, 3406C, 375, 375 L, 5080, 578, 621E, 621F, 623E, 627F, 814B, 824C, 824G, 825C, 825G, 826C, 826G, 980C, 980F, 980F II, 980G, D350E, D400E, D40D, D8N, D8R, G3406, RR-250, ...
4P9372
PUMP GP-WATER
16G, 245B, 3406, 3406B, 375, 578, 621E, 623E, 627E, 814B, 824C, 825C, 826C, 980C, 980F, D40D, D8N, G3406, RR-250, SS-250
16G, 245B, 3406, 3406B, 375, 578, 621E, 623E, 627E, 814B, 824C, 825C, 826C, 980C, 980F, D40D, D8N, G3406, RR-250, SS-250
4N0735
PUMP GP-ENGINE OIL
245, 245B, 245D, 3406, 375, 375 L, 5080, 578, 583R, 621B, 983B, D8N, D8R, D8R II
245, 245B, 245D, 3406, 375, 375 L, 5080, 578, 583R, 621B, 983B, D8N, D8R, D8R II
1614112
PUMP GP-ENGINE OIL
375, 375 L, 5080, 578, 583R, D8N, D8R, D8R II
375, 375 L, 5080, 578, 583R, D8N, D8R, D8R II
1052508
PUMP AS-FUEL PRIMING
120G, 12G, 12H, 12H ES, 12H NA, 140H, 140H ES, 140H NA, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 163H, 163H NA, 16G, 16H, 16H NA, 214B, 235, 3114, 3116, 3126, 3126B, 3126E, 3176, 3176B, 3176C, 3196,...
120G, 12G, 12H, 12H ES, 12H NA, 140H, 140H ES, 140H NA, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 163H, 163H NA, 16G, 16H, 16H NA, 214B, 235, 3114, 3116, 3126, 3126B, 3126E, 3176, 3176B, 3176C, 3196,...
3542953
PUMP GP-METERING
924H, 924HZ
924H, 924HZ
3840607
PUMP GP-UNIT INJECTOR HYD
120K, 120K 2, 12K, 12M, 140K 2, 140M, 160K, 521B, 522B, 525C, 535C, 541 2, 545C, 552 2
120K, 120K 2, 12K, 12M, 140K 2, 140M, 160K, 521B, 522B, 525C, 535C, 541 2, 545C, 552 2
3522139
PUMP GP-WATER
120H, 120K, 120K 2, 12K, 12M, 135H, 140G, 140K, 140K 2, 140M, 160K, 3126, 3126B, 3126E, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325C, 325C FM, 325D, 325D FM, 325D FM LL, 325D L, 325...
120H, 120K, 120K 2, 12K, 12M, 135H, 140G, 140K, 140K 2, 140M, 160K, 3126, 3126B, 3126E, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325C, 325C FM, 325D, 325D FM, 325D FM LL, 325D L, 325...
8E7538
PUMP GP-GEAR
980F, 980F II
980F, 980F II
1W4776
PUMP GP-PRELUBE
3512, 3512B, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, C280-12, C280-16, C280-6, C280-8, G3508, G3508B, G3512, G3512B, G3516, G3516B, G3520B, G3606, G3606B, G3608, G3612, G3616
3512, 3512B, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, C280-12, C280-16, C280-6, C280-8, G3508, G3508B, G3512, G3512B, G3516, G3516B, G3520B, G3606, G3606B, G3608, G3612, G3616
1500720
PUMP GP-GEAR
CP-663E, CS-663E, CS-683E, M318, M320
CP-663E, CS-663E, CS-683E, M318, M320
3197356
PUMP GP-FUEL TRANSFER
C1.1, CB-14
C1.1, CB-14
3223830
PUMP GP-FUEL TRANSFER
3516B, 5230, 5230B, 785C, 789, 789B, 789C, 789D, 793C, 793D, 994D, 994F, 994H
3516B, 5230, 5230B, 785C, 789, 789B, 789C, 789D, 793C, 793D, 994D, 994F, 994H
2703948
PUMP GP-PISTON
CP-56, CP-64, CP-76, CS-56, CS-64, CS-74
CP-56, CP-64, CP-76, CS-56, CS-64, CS-74
2765073
PUMP & MTG GP-LUBRICATION
966H, 972H
966H, 972H
1336899
PUMP GP-GEAR
320B, 322B L, 322B LN, 325B, 325B L, 539, M325B
320B, 322B L, 322B LN, 325B, 325B L, 539, M325B
1425071
PUMP GP-FUEL INJECTION
3054, AP-800C, BG-225B, CB-534C, CB-535B, CP-433C, CS-431C, CS-433C, PF-290B, PS-200B, PS-360B, TH103, TH62, TH63, TH82, TH83
3054, AP-800C, BG-225B, CB-534C, CB-535B, CP-433C, CS-431C, CS-433C, PF-290B, PS-200B, PS-360B, TH103, TH62, TH63, TH82, TH83