1727771 PUMP GP-WATER Caterpillar parts
3304, 3304B, 3306, 3306B
Rating:
Alternative (cross code) number:
CA1727771
172-7771
1727771
CA1727771
172-7771
1727771
Weight: 27 pounds 12 kg.
GEN SET ENGINE, MARINE ENGINE,
Related part:
1727771
PUMP GP-WATER
0R1006
R
1727771
PUMP-WATER-YM
4194646
CL
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
172-7771 WATER PUMP Suitable For Caterpillar 1727771
KMP BRAND Suitable for Caterpillar
KMP BRAND Suitable for Caterpillar
1727771 Pump GP-Water (New AFTERMARKET) - G&T Engine Parts
G&T Engine Parts Condition: NEW AFTERMARKET || Weight: 29.7 lbs || Dimensions: 10.82-10.82-16.46 in || Items are sold by part number only. Picture is for illustration purposes and the part or parts may be different in color or quantity. || Use of any OEM manufacturer name is not intended to represent any relationship between the two companies, instead it indicates that we sell replacement parts that are compatible with OEM components.
G&T Engine Parts Condition: NEW AFTERMARKET || Weight: 29.7 lbs || Dimensions: 10.82-10.82-16.46 in || Items are sold by part number only. Picture is for illustration purposes and the part or parts may be different in color or quantity. || Use of any OEM manufacturer name is not intended to represent any relationship between the two companies, instead it indicates that we sell replacement parts that are compatible with OEM components.
This part in 5 request:
Show.
This information for suppliers only!
2023-02-06
2021-09-28
2021-09-28
2021-03-09
2018-06-06
Compatible equipment models: 1727771:
Information:
Remote Voltage Control
Partial View Of Regulator
(1) Potentiometer. (2) Jumper. (3) Regulator.Generator output voltage level can be controlled from a remote location. This is done by connecting potentiometer (1) between terminals 6 and 7 on voltage regulator (3). Remove jumper (2) between terminals 4 and 7 for remote voltage level control.For acceptable voltage control, the remote mounted potentiometer must be 10k ohms 5% with three turns and a dielectric strength of 1000 VAC minimum.The terminals of the remote mounted potentiometer are fragile. The wiring connected to remote mounted potentiometer (1) should not have a diameter larger than 18 gauge. Larger diameter wire is not recommended. The wire should be 600 volt class with a 90°C (194°F) insulation. Either jumper (2) or remote potentiometer (1) is required for regulator operation.Manual Voltage Control
Manual Voltage Control Schematic With Power Transformer Manual Voltage Control Schematic With Power Transformer and Sensing
Manual Voltage Control Panel
(1) Switch (OFF, AUTO and MAN positions). (2) Voltage control rheostat. (3) Fuse.The manual voltage control can be used to control generator voltage when there is a failure in the generator regulator assembly. It will manually control the current flow to exciter stator L1.The manual voltage control panel has switch (1) and voltage control rheostat (2) for the manual operating mode.Switch (1) is used to make the selection between AUTO, MAN and OFF. In the "AUTO" position, the VR3 regulator controls the generator voltage. In the "OFF" position, the voltage will go to zero. In the "MAN" position, generator voltage is controlled by voltage control rheostat (2). The Manual Voltage Control Panel must not be installed in a location that is subject to engine vibrations or directly to outside weather. When the manual voltage control is operating in the "Manual" mode, it is not necessary for the VR3 regulator to be connected to the generator. However, the manual control must remain connected to generator sensing lines No. 20 and No. 24.Voltage Droop Transformer And Adjustment Rheostat For Parallel Operation
Generator And Regulator Schematic
(1) Voltage droop transformer. (2) Voltage droop rheostat. (3) Lead. (4) Main stator.Operation of generators in parallel requires voltage droop as reactive load is increased. Droop transformer (1) and adjustment rheostat (2) are required to provide the voltage droop function. The transformer senses load current in lead (3) of main stator (4). Droop rheostat (2) provides adjustment of droop voltage. Rheostat (2) is located directly next to the regulator on the regulator mounting bracket.Transformer (1) is standard on some generators and is an attachment on others. Rheostat (2) is an attachment on all units. Droop transformer (1) is a special ratio transformer. Droop transformer (1) must be installed on generator phase lead T2 with transformer polarity connections as shown.
Partial View Of Regulator
(1) Potentiometer. (2) Jumper. (3) Regulator.Generator output voltage level can be controlled from a remote location. This is done by connecting potentiometer (1) between terminals 6 and 7 on voltage regulator (3). Remove jumper (2) between terminals 4 and 7 for remote voltage level control.For acceptable voltage control, the remote mounted potentiometer must be 10k ohms 5% with three turns and a dielectric strength of 1000 VAC minimum.The terminals of the remote mounted potentiometer are fragile. The wiring connected to remote mounted potentiometer (1) should not have a diameter larger than 18 gauge. Larger diameter wire is not recommended. The wire should be 600 volt class with a 90°C (194°F) insulation. Either jumper (2) or remote potentiometer (1) is required for regulator operation.Manual Voltage Control
Manual Voltage Control Schematic With Power Transformer Manual Voltage Control Schematic With Power Transformer and Sensing
Manual Voltage Control Panel
(1) Switch (OFF, AUTO and MAN positions). (2) Voltage control rheostat. (3) Fuse.The manual voltage control can be used to control generator voltage when there is a failure in the generator regulator assembly. It will manually control the current flow to exciter stator L1.The manual voltage control panel has switch (1) and voltage control rheostat (2) for the manual operating mode.Switch (1) is used to make the selection between AUTO, MAN and OFF. In the "AUTO" position, the VR3 regulator controls the generator voltage. In the "OFF" position, the voltage will go to zero. In the "MAN" position, generator voltage is controlled by voltage control rheostat (2). The Manual Voltage Control Panel must not be installed in a location that is subject to engine vibrations or directly to outside weather. When the manual voltage control is operating in the "Manual" mode, it is not necessary for the VR3 regulator to be connected to the generator. However, the manual control must remain connected to generator sensing lines No. 20 and No. 24.Voltage Droop Transformer And Adjustment Rheostat For Parallel Operation
Generator And Regulator Schematic
(1) Voltage droop transformer. (2) Voltage droop rheostat. (3) Lead. (4) Main stator.Operation of generators in parallel requires voltage droop as reactive load is increased. Droop transformer (1) and adjustment rheostat (2) are required to provide the voltage droop function. The transformer senses load current in lead (3) of main stator (4). Droop rheostat (2) provides adjustment of droop voltage. Rheostat (2) is located directly next to the regulator on the regulator mounting bracket.Transformer (1) is standard on some generators and is an attachment on others. Rheostat (2) is an attachment on all units. Droop transformer (1) is a special ratio transformer. Droop transformer (1) must be installed on generator phase lead T2 with transformer polarity connections as shown.
Caterpillar SIS machinery equipment:
Caterpillar SIS
3304 Industrial Engine 10E00300-UP »
172-7771
PUMP GP-WATER
3304 Marine Engine 13E00300-UP »
172-7771
PUMP GP-WATER
3306 Marine Engine 84Z00001-UP »
172-7771
PUMP GP-WATER
3306 Industrial Engine 66D49919-UP »
172-7771
PUMP GP-WATER
3306 Industrial Engine 64Z05381-UP »
172-7771
PUMP GP-WATER
3306 Generator Set 85Z03764-UP »
172-7771
PUMP GP-WATER
3304 Industrial Engine 02B17737-UP »
172-7771
PUMP GP-WATER
3304B Generator Set 83Z03096-UP »
172-7771
PUMP GP-WATER
3304 Industrial Engine 04B26769-UP »
172-7771
PUMP GP-WATER
3304B Marine Auxiliary & Generator Set 1PS00001-UP »
172-7771
PUMP GP-WATER
3306B Generator Set 9NR00001-UP »
172-7771
PUMP GP-WATER
3306 Industrial Engine 23C02002-UP »
172-7771
PUMP GP-WATER
Caterpillar parts catalog:
Parts pump Caterpillar catalog:
6N7606
PUMP GP-GOV & FUEL INJ
1673C, 3306
1673C, 3306
4N4314
PUMP GP-FUEL PRIMING
140B, 1673C, 225, 225D, 227, 229, 231D, 3116, 3126, 3208, 3304, 3306, 518, 528, 571G, 572G, 613C, 627B, 637D, 639D, 814, 815, 816, 910, 920, 930, 931B, 931C, 931C II, 935B, 935C, 935C II, 950, 966C, 9...
140B, 1673C, 225, 225D, 227, 229, 231D, 3116, 3126, 3208, 3304, 3306, 518, 528, 571G, 572G, 613C, 627B, 637D, 639D, 814, 815, 816, 910, 920, 930, 931B, 931C, 931C II, 935B, 935C, 935C II, 950, 966C, 9...
1W6539
PUMP GP-FUEL INJECTION
120G, 12G, 130G, 140G, 143H, 14G, 160G, 160H, 215, 215B, 215C, 215D, 219D, 225, 225D, 229, 229D, 235, 235B, 3204, 3304, 3304B, 3306, 3306B, 508, 515, 518, 518C, 525, 527, 528, 571G, 572G, 615, 615C, 6...
120G, 12G, 130G, 140G, 143H, 14G, 160G, 160H, 215, 215B, 215C, 215D, 219D, 225, 225D, 229, 229D, 235, 235B, 3204, 3304, 3304B, 3306, 3306B, 508, 515, 518, 518C, 525, 527, 528, 571G, 572G, 615, 615C, 6...
4W2448
PUMP GP-ENGINE OIL
120G, 12G, 130G, 140G, 14G, 160G, 215B, 215C, 215D, 219D, 225, 225D, 229, 229D, 235, 235B, 235C, 3304, 3304B, 3306, 3306B, 518, 528, 561D, 571G, 572G, 615, 615C, 621E, 621R, 627B, 627E, 637D, 637E, 65...
120G, 12G, 130G, 140G, 14G, 160G, 215B, 215C, 215D, 219D, 225, 225D, 229, 229D, 235, 235B, 235C, 3304, 3304B, 3306, 3306B, 518, 528, 561D, 571G, 572G, 615, 615C, 621E, 621R, 627B, 627E, 637D, 637E, 65...
2W8001
PUMP GP-WATER
120B, 140B, 215C, 215D, 219D, 225D, 229, 229D, 235, 235B, 235C, 330, 330 FM L, 330 L, 3304, 3304B, 3306, 3306B, 350, 515, 525, 527, 561D, 571G, 572G, 627B, 627E, 627F, 637D, 637E, 639D, 65, 65C, 70C, ...
120B, 140B, 215C, 215D, 219D, 225D, 229, 229D, 235, 235B, 235C, 330, 330 FM L, 330 L, 3304, 3304B, 3306, 3306B, 350, 515, 525, 527, 561D, 571G, 572G, 627B, 627E, 627F, 637D, 637E, 639D, 65, 65C, 70C, ...
4P9827
PUMP GP-FUEL INJECTION
12G, 12H, 12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160H, 160H ES, 160H NA, 163H NA, 235B, 330, 330 FM L, 330 L, 3306, 3306B, 3306C, 330B, 330B L, 350, 545, 572R, 611, 615C, 627...
12G, 12H, 12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160H, 160H ES, 160H NA, 163H NA, 235B, 330, 330 FM L, 330 L, 3306, 3306B, 3306C, 330B, 330B L, 350, 545, 572R, 611, 615C, 627...
9H2256
PUMP ASSEMBLY
120, 12E, 12F, 140, 14E, 1673, 1673B, 1673C, 1674, 1676, 3160, 3304, 3306, 561B, 561C, 627, 637, 814, 815, 816, 920, 930, 941, 950, 951B, 955H, 955K, 955L, 966C, 977H, 977K, 977L, 980B, D320A, D330A, ...
120, 12E, 12F, 140, 14E, 1673, 1673B, 1673C, 1674, 1676, 3160, 3304, 3306, 561B, 561C, 627, 637, 814, 815, 816, 920, 930, 941, 950, 951B, 955H, 955K, 955L, 966C, 977H, 977K, 977L, 980B, D320A, D330A, ...
1550067
PUMP GP-WATER
3304, 3304B, 3306, 3306B, 515, 525, 530B
3304, 3304B, 3306, 3306B, 515, 525, 530B
1052508
PUMP AS-FUEL PRIMING
120G, 12G, 12H, 12H ES, 12H NA, 140H, 140H ES, 140H NA, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 163H, 163H NA, 16G, 16H, 16H NA, 214B, 235, 3114, 3116, 3126, 3126B, 3126E, 3176, 3176B, 3176C, 3196,...
120G, 12G, 12H, 12H ES, 12H NA, 140H, 140H ES, 140H NA, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 163H, 163H NA, 16G, 16H, 16H NA, 214B, 235, 3114, 3116, 3126, 3126B, 3126E, 3176, 3176B, 3176C, 3196,...
1375541
PUMP GP-FUEL PRIMING
120G, 12G, 130G, 140G, 140H, 143H, 14G, 14H, 160G, 160H, 163H, 1673C, 16H, 235B, 24H, 3116, 311C, 311D LRR, 3126, 3126B, 3126E, 312C, 312C L, 312D, 312D L, 313D, 314C, 314D CR, 314D LCR, 315C, 315D L,...
120G, 12G, 130G, 140G, 140H, 143H, 14G, 14H, 160G, 160H, 163H, 1673C, 16H, 235B, 24H, 3116, 311C, 311D LRR, 3126, 3126B, 3126E, 312C, 312C L, 312D, 312D L, 313D, 314C, 314D CR, 314D LCR, 315C, 315D L,...
4W0788
PUMP AS-FUEL PRIMING
14G, 205B, 215B, 224B, 235, 245, 3114, 3116, 320 L, 330 L, 3304, 3304B, 3306, 3306B, 350, 3516, 375, 446, 528, 572G, 621, 910E, 920, 926, 936F, 943, 950B, 950F, 953, 953C, 966F, 980C, 980F, C-12, C12,...
14G, 205B, 215B, 224B, 235, 245, 3114, 3116, 320 L, 330 L, 3304, 3304B, 3306, 3306B, 350, 3516, 375, 446, 528, 572G, 621, 910E, 920, 926, 936F, 943, 950B, 950F, 953, 953C, 966F, 980C, 980F, C-12, C12,...
1W3010
PUMP AS-FUEL INJECTION
3208, 3306, 613C, PR-1000
3208, 3306, 613C, PR-1000
1451077
PUMP GP-CHARGE
CX35-P800, D3C III, D6N, D6T, D6T LGP, D6T LGPPAT, D6T XL, TH31-E61, TH35-E81
CX35-P800, D3C III, D6N, D6T, D6T LGP, D6T LGPPAT, D6T XL, TH31-E61, TH35-E81
1897651
PUMP GP-LUBRICATION
988G, 990 II, 992G
988G, 990 II, 992G
2797721
PUMP & MTG GP-MAIN HYDRAULIC
312D, 312D L, 313D, 314D CR, 314D LCR
312D, 312D L, 313D, 314D CR, 314D LCR
3084733
PUMP GP-FUEL INJECTION
AP-650B, AP-800D, CP-533E, CS-533E, PS-360C
AP-650B, AP-800D, CP-533E, CS-533E, PS-360C
6T4411
PUMP GP-TRANSMISSION
931B, 931C, D3B, D3C, D3C II
931B, 931C, D3B, D3C, D3C II
4W0050
PUMP GP-AUXILIARY SEA WATER
3408, 3412, 3412C, 3412D, 3412E
3408, 3412, 3412C, 3412D, 3412E
4P8538
PUMP GP-WATER
3114, 3116, 3126
3114, 3116, 3126
1712948
PUMP GP-ENGINE OIL
216, 236, 247, 267, 3034, 906
216, 236, 247, 267, 3034, 906
3803898
PUMP GP-FUEL PRIMING
3516B, 3516C
3516B, 3516C
2405572
PUMP GP-FUEL INJECTION
3054C, CS-323C, CS-423E
3054C, CS-323C, CS-423E
2466103
PUMP & MTG GP-PISTON
120M, 12M
120M, 12M
1980915
PUMP GP-PISTON
65E, 75E, 85E, 95E
65E, 75E, 85E, 95E