2718693 PUMP GP-WATER Caterpillar parts
C13, C9, TH31-E61
Rating:
Alternative (cross code) number:
CA2718693
271-8693
2718693
CA2718693
271-8693
2718693
Weight: 22 pounds 10 kg.
PETROLEUM TRANSMISSION, TRUCK ENGINE,
Compatible equipment models: 2718693:
Information:
Reference: Understanding "Shorts," "Opens" and "Intermittents; and How To Troubleshoot A Short-To-Ground In Power Wiring in this issue.Fuses and circuit breakers are often reported as the CAUSE of failure. This is very seldom correct. Open fuses and circuit breakers are most often the RESULT of an electrical system overload. These components are electrical "flow control valves" connected in series with a given circuit to protect wiring from high current damage.
Fuses are made of an electrical conductor with a low melting temperature that melts "OPEN" during an overload condition. Circuit breakers on earthmoving products use a bimetallic disk that closes the circuit between the two breaker terminals (generator sets use a different type). During overload, the disk heats up and snaps ("oil cans") to open the circuit. On a manual reset breaker, the push button snaps the disk into a position that again closes the circuit between the breaker terminals. The disk in an automatic-reset breaker will snap closed when it cools down.
Fuses and circuit breakers are almost never the CAUSE of failure. When troubleshooting the actual cause, report (on a SIMS or warranty claim) the part number of the harness or component that caused the fuse to blow or breaker to trip. Fuse Failure Modes
Open
An open fuse is the result of system overload. Fuses with the element visible can give a clue as to the cause. Testing on a questionable fuse only requires a 6V7070 Multimeter (or equivalent) on the 200 ohm scale. A good fuse will read less than approximately 0.2 ohms. An open fuse will read "OL" for open circuit.
1. The glass or plastic housing is smoked or blackened. This is caused by gross circuit overload far beyond the fuse rating. This is usually caused by a short circuit-to-ground from: ...Incorrect troubleshooting as with a screwdriver.
...A component short as in a forward warning horn.
...A harness short where a wire (conductor) is pinched to make a connection to ground.
2. The glass or plastic housing is clear showing the fuse element simply melted open. This is caused by a gentle overload somewhat greater than the fuse rating.Will not fit fuse holder
1. Incorrect type or size of fuse for holder.2. Supplier tolerances are incorrect.Breaker Failure Modes
Open
An open circuit breaker is an automatic or manual breaker that will not reset (reads "OL" on 6V7070 Multimeter). This usually occurs from gross circuit overload far beyond the breaker current rating. This is usually caused by a short circuit-to-ground from: ...Incorrect troubleshooting as with a screwdriver....A component short as in a forward warning horn....A harness short where a wire (conductor) is pinched to make a connection to ground.
Failure of a circuit breaker to reset is often caused by a melted disk or a disk that was so hot during overload that it is warped and cannot be reset to a closed position.
Shorted
A shorted circuit breaker, one that will not open under an overload, is rare and might be found in a circuit with wiring and/or harness damage. This may possibly
Fuses are made of an electrical conductor with a low melting temperature that melts "OPEN" during an overload condition. Circuit breakers on earthmoving products use a bimetallic disk that closes the circuit between the two breaker terminals (generator sets use a different type). During overload, the disk heats up and snaps ("oil cans") to open the circuit. On a manual reset breaker, the push button snaps the disk into a position that again closes the circuit between the breaker terminals. The disk in an automatic-reset breaker will snap closed when it cools down.
Fuses and circuit breakers are almost never the CAUSE of failure. When troubleshooting the actual cause, report (on a SIMS or warranty claim) the part number of the harness or component that caused the fuse to blow or breaker to trip. Fuse Failure Modes
Open
An open fuse is the result of system overload. Fuses with the element visible can give a clue as to the cause. Testing on a questionable fuse only requires a 6V7070 Multimeter (or equivalent) on the 200 ohm scale. A good fuse will read less than approximately 0.2 ohms. An open fuse will read "OL" for open circuit.
1. The glass or plastic housing is smoked or blackened. This is caused by gross circuit overload far beyond the fuse rating. This is usually caused by a short circuit-to-ground from: ...Incorrect troubleshooting as with a screwdriver.
...A component short as in a forward warning horn.
...A harness short where a wire (conductor) is pinched to make a connection to ground.
2. The glass or plastic housing is clear showing the fuse element simply melted open. This is caused by a gentle overload somewhat greater than the fuse rating.Will not fit fuse holder
1. Incorrect type or size of fuse for holder.2. Supplier tolerances are incorrect.Breaker Failure Modes
Open
An open circuit breaker is an automatic or manual breaker that will not reset (reads "OL" on 6V7070 Multimeter). This usually occurs from gross circuit overload far beyond the breaker current rating. This is usually caused by a short circuit-to-ground from: ...Incorrect troubleshooting as with a screwdriver....A component short as in a forward warning horn....A harness short where a wire (conductor) is pinched to make a connection to ground.
Failure of a circuit breaker to reset is often caused by a melted disk or a disk that was so hot during overload that it is warped and cannot be reset to a closed position.
Shorted
A shorted circuit breaker, one that will not open under an overload, is rare and might be found in a circuit with wiring and/or harness damage. This may possibly
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts pump Caterpillar catalog:
3030289
PUMP GP-GEAR
307C, 308C
307C, 308C
3965690
PUMP GP-SUMP
3508C, 3512C, 3516C
3508C, 3512C, 3516C
2358725
PUMP GP-FILTER & FUEL TRANSFER
12H, 12M, 140G, 140M, 160M, 2290, 2390, 2391, 2491, 2590, 511, 521, 521B, 522, 522B, 525C, 532, 535C, 541, 541 2, 545C, 551, 552, 552 2, 784C, 785, 785B, 785C, 785D, 789C, 793C, 793D, 797, 797B, 815B,...
12H, 12M, 140G, 140M, 160M, 2290, 2390, 2391, 2491, 2590, 511, 521, 521B, 522, 522B, 525C, 532, 535C, 541, 541 2, 545C, 551, 552, 552 2, 784C, 785, 785B, 785C, 785D, 789C, 793C, 793D, 797, 797B, 815B,...
3641006
PUMP & MTG GP-MAIN HYDRAULIC
311F LRR
311F LRR
9D8655
PUMP GP-GEAR
768C, 769C, 769D, 771C, 771D
768C, 769C, 769D, 771C, 771D
1350472
PUMP & LINES GP-REAR AXLE LUBE
793B, 793C
793B, 793C
8W2291
PUMP & MOUNTING GP
12G, 130G, 140G, 160G
12G, 130G, 140G, 160G
2928768
PUMP GP-PISTON
966H, 972H
966H, 972H
6G3330
PUMP GP-VANE
651E, 657E
651E, 657E
1165428
PUMP & MTG GP-FUEL TRANSFER
140H, 143H, 14H, 160H, 163H, 16H, 3176C, 3196, 345B, 345B II, 345B II MH, 345B L, 365B, 365B II, 365B L, 480, 65E, 725, 730, 75D, 75E, 814F, 815F, 816F, 85D, 85E, 95E, 966G II, 972G II, C-10, C-12, C1...
140H, 143H, 14H, 160H, 163H, 16H, 3176C, 3196, 345B, 345B II, 345B II MH, 345B L, 365B, 365B II, 365B L, 480, 65E, 725, 730, 75D, 75E, 814F, 815F, 816F, 85D, 85E, 95E, 966G II, 972G II, C-10, C-12, C1...
3277263
PUMP & MTG GP-MAIN HYDRAULIC
330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 340D L, 340D2 L
330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 340D L, 340D2 L