Illustration 1 g00790608
Schematic of the Proportional Solenoid (Forward) of the Left Drive PumpThis diagnostic code is recorded when the ECM reads the voltage of the solenoid circuit as being above normal or shorted to +battery.The possible causes of this diagnostic code are listed:
The energize circuit of the solenoid is shorted to the +battery circuit.
The ECM has failed. This is unlikely. Note: Ensure that CID 1703 FMI 03 is on hold and that the diagnostic indicator is illuminated. The nominal coil resistance at room temperature is 4.1 .3 ohms.System Response:The action lamp and the action alarm is ON. The diagnostic code will cause the transmission to shift to NEUTRAL until the diagnostic code is corrected.Test Step 1. CHECK THE SOLENOID CIRCUIT FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness from the solenoid.
Disconnect J1 and J2 machine harness connectors from the ECM.
At the machine harness connector, measure the resistance from signal contact J2-40 (wire K994-BU) to all contacts that are used in the machine harness connectors for the ECM.Expected Result:Each resistance measurement should be greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to test step 2.
NOT OK - One or more resistance measurements is not correct. There is a short in the machine harness. The short is between signal contact J2-40 (wire K994-BU) and the circuit with the low resistance measurement. Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the contacts of the harness connectors and clean the contacts.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Clear all of the logged diagnostic codes.
Operate the machine.
Check if the CID 1703 FMI 03 is present. Expected Result:The diagnostic code for the solenoid is NOT present. Results:
YES - The diagnostic code is NOT present. The diagnostic code does not exist at this time. Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP
NO - The diagnostic code has not been corrected. The ECM may have failed. Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
Parts pump Caterpillar catalog:
20R4732
PUMP GP-FUEL INJ
Caterpillar
Caterpillar
20R4731
PUMP GP-FUEL INJ
Caterpillar
Caterpillar
10R4425
PUMP GP-FUEL INJ
Caterpillar
Caterpillar
20R3425
PUMP GP-F XFR
Caterpillar
Caterpillar
20R0965
PUMP GP-F XFR
Caterpillar
Caterpillar
0R1520
PUMP GP-OIL
Caterpillar
Caterpillar
0R7984
PUMP GP-PS-V-A
Caterpillar
Caterpillar
2992044
PUMP-YM
Caterpillar
Caterpillar
3148533
PUMP GP-YM
Caterpillar
Caterpillar
3119444
PUMP-FT-YM
Caterpillar
Caterpillar
3451978
PUMP-GEAR-YM
Caterpillar
Caterpillar
3309279
PUMP GP-FT-YM
Caterpillar
Caterpillar