AVSPARE.COM
parts catalog

PUMP GP-STEERING IMPLEMENT 3G5387 - Caterpillar


3G5387 PUMP GP-STEERING IMPLEMENT Caterpillar parts 910, G910
Rating:
53
Alternative (cross code) number:
CA3G5387
3G-5387
3G5387
Caterpillar 3G5387 PUMP GP-STEERING IMPLEMENT
Weight: 184 pounds 83 kg.

Buy PUMP GP-STEERING IMPLEMENT 3G5387 Caterpillar genuine, new aftermarket tractor parts with delivery
COMPACT WHEEL LOADER, WHEEL LOADER,

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
$1,089.60

22 Oct 2025

CN: SpeedShield Aut
8J8813 3G5387 Pump Group Gear Fits for Caterpillar - Model 910 G910 - Compatible Equipment Compact Wheel Loader
KemraZJW Part Name: Pump Group Gear || Part Number:8J8813 3G5387 || Application: Fits for Caterpillar - Model 910 G910 - Compatible Equipment Compact Wheel Loader
$1,071.44

22 Oct 2025

CN: CarTech Direct
8J8813 3G5387 Pump Group Gear Fits for Caterpillar - Model 910 G910 - Compatible Equipment Compact Wheel Loader
KxmyaYDX Part Name: Pump Group Gear || Part Number:8J8813 3G5387 || Application: Fits for Caterpillar - Model 910 G910 - Compatible Equipment Compact Wheel Loader
$1,044.20

22 Oct 2025

CN: DriveMasters Pa
8J8813 3G5387 Pump Group Gear Fits for Caterpillar - Model 910 G910 - Compatible Equipment Compact Wheel Loader
KmexyCWH Part Name: Pump Group Gear || Part Number:8J8813 3G5387 || Application: Fits for Caterpillar - Model 910 G910 - Compatible Equipment Compact Wheel Loader
Number on catalog scheme:
  For full view, you need register

Compatible equipment models: 3G5387:

COMPACT WHEEL LOADER  910  
WHEEL LOADER  G910   Caterpillar

Information:

Remote Voltage Control
Partial View Of Regulator
(1) Potentiometer. (2) Jumper. (3) Regulator.Generator output voltage level can be controlled from a remote location. This is done by connecting potentiometer (1) between terminals (6 and 7) on voltage regulator (3). Remove jumper (2) between terminals (4 and 7) for remote voltage level control.For acceptable voltage control, the remote mounted potentiometer must be 10k ohms 5% with three turns and a dielectric strength of 1000 VAC minimum.The terminals of the remote mounted potentiometer are fragile. The wiring connected to remote mounted potentiometer (1) should not have a diameter larger than 18 gauge. Larger diameter wire is not recommended. The wire should be 600 volt class with a 90°C (194°F) insulation. Either jumper (2) or remote potentiometer (1) is required for regulator operation.Series Boost
Series Boost Schematic With Earlier One Fuse VR3 Series Boost Schematic With Current Two Fuse VR3 Series boost lets self-excited SR4 generators stay on the line, for approximately 10 seconds, when there is a short in the generating or load circuits. This gives circuit breakers a chance to trip in sequence. When circuit breakers trip in sequence, there is less chance for a loss of power to all of the electrical system.Series boost consists of the series boost module and current transformer T2.Reference: For the most current information on connecting to the primary side of the transformer, see Special Instructions, SELS0071.Voltage sensing and power are applied to the series boost module from the voltage sensing terminals 22 and 24 of the regulator.When the sensed voltage is within normal limits, an electrical signal is sent to the gate of a triac located in the series boost module. This triac short circuits the current transformer T2. This prevents any series boost during normal operation.If there is a short circuit that causes the voltage at the regulator sensing terminals to drop to a low value, the control signal to the gate of the triac will be turned off. Current from current transformer T2 will be rectified and applied directly to exciter stator L1. This field current will be enough to give at least three times full load current into a short circuit. After approximately ten seconds a timer within the series boost module will again cause a control signal to be applied to the gate of the triac. The triac will short circuit the current transformer T2. Current flow to exciter stator L1 will be zero until the short circuit is corrected.Manual Voltage Control
Manual Voltage Control Schematic With Earlier One Fuse VR3 Manual Voltage Control Schematic With Current Two Fuse VR3
Manual Voltage Control Panel
(1) Switch (OFF, AUTO and MAN positions). (2) Voltage control rheostat. (3) Fuse.The manual voltage control can be used to control generator voltage when there is a failure in the generator regulator assembly. It will manually control the current flow to exciter stator L1.The manual voltage control panel has switch (1) and voltage control rheostat (2) for the manual operating mode.Switch (1) is used to make the selection between

Caterpillar parts catalog:

Caterpillar parts catalog
910 WHEEL LOADER 40Y00001-UP (MACHINE) POWERED BY 3204 ENGINE
910 WHEEL LOADER 41Y00001-UP (MACHINE) POWERED BY 3204 ENGINE


Parts pump Caterpillar catalog:

1W0568 PUMP GP-FUEL TRANSFER
215, 215B, 3204, 508, 910, 916, 926, 926A, 931B, 931C, 931C II, 935B, 935C, 935C II, 943, 953, D3B, D3C, D3C II, D4B, D4C, D4C II, D4H, D4HTSK II, D5C, E180, G910, G916, G926, IT12, IT18, IT18B, IT28,...
9P2653 PUMP GP-GEAR
910, 931, 931B, 931C, 931C II, D3, D3B, D3C, D3C II, G910, IT12
4N0660 PUMP GP-WATER
215, 215B, 3204, 508, 910, 916, 926, 926A, 931, 931B, 931C, 931C II, 935B, 935C, 935C II, 943, 953, D3, D3B, D3C, D3C II, D4B, D4C, D4C II, D4H, D4HTSK II, D5C, E180, G910, G916, G926, IT12, IT18, IT1...
4N0193 PUMP GP-ENGINE OIL
910, 931, 931B, 943, D3, D3B
9P7239 PUMP GP-GEAR
910, 931B, 931C, 931C II, 935B, 935C, 935C II, D3B, D3C, D3C II, D4B, D4C, D4C II, G910, IT12
4N4314 PUMP GP-FUEL PRIMING
140B, 1673C, 225, 225D, 227, 229, 231D, 3116, 3126, 3208, 3304, 3306, 518, 528, 571G, 572G, 613C, 627B, 637D, 639D, 814, 815, 816, 910, 920, 930, 931B, 931C, 931C II, 935B, 935C, 935C II, 950, 966C, 9...
1W6539 PUMP GP-FUEL INJECTION
120G, 12G, 130G, 140G, 143H, 14G, 160G, 160H, 215, 215B, 215C, 215D, 219D, 225, 225D, 229, 229D, 235, 235B, 3204, 3304, 3304B, 3306, 3306B, 508, 515, 518, 518C, 525, 527, 528, 571G, 572G, 615, 615C, 6...
6E2927 PUMP GP-VANE
926, 926A, IT28B
9J5075 PUMP GP-VANE
621B, 621E, 621F, 621G, 627F, 627G
3615093 PUMP GP-FUEL PRIMING
C13, C15, C18, C9.3, CX31-C13I, CX31-C18I, CX35-C18I
9Y0491 PUMP GP-GOV & FUEL INJ
3208, CB-614, CS-551, PS-500
Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.