4575274 PUMP GP-HAND Caterpillar parts
Rating:
Alternative (cross code) number:
CA4575274
457-5274
4575274
CA4575274
457-5274
4575274
Weight: 1 pounds 0 kg.
Information:
Procedure
Illustration 1 g00624922
(1) Main Disconnect Switch on the Control Panel.
Turn the grapple/magnet switch to the grapple position in order to stop the generator. Move the main disconnect switch (1) to the OFF position. Place a lockout tag on the main disconnect switch (1).
Place the magnet on the ground. Disconnect the leads that come from the front of the machine.
Attach the resistance bridge or the meter to the two leads of the magnet. Measure the resistance. Compare the reading to the original readings from the manufacturer. If the measurements are within tolerance, proceed to 5. If the readings are not within tolerance, proceed to 4.
Disconnect the leads from the terminals of the magnet. Take a reading directly from the terminals of the magnet. If the readings are now within tolerance, replace the leads of the magnet. If the readings are not within tolerance, replace the magnet.
Connect the two leads from the megohmmeter to two clean areas of the housing of the magnet. Take a reading. The resistance reading should be zero. If the reading is not zero, place the leads in a different place and measure the resistance again. Once you have obtained a zero reading on the megohmmeter, remove one of the leads and attach the lead to one terminal of the magnet. Make sure that the other lead is not touching the magnet or any metal. Take a resistance reading. If the reading is above 0.05 megohm, the magnet is within tolerance. If the reading is below 0.05 megohm, replace the magnet.
Illustration 1 g00624922
(1) Main Disconnect Switch on the Control Panel.
Turn the grapple/magnet switch to the grapple position in order to stop the generator. Move the main disconnect switch (1) to the OFF position. Place a lockout tag on the main disconnect switch (1).
Place the magnet on the ground. Disconnect the leads that come from the front of the machine.
Attach the resistance bridge or the meter to the two leads of the magnet. Measure the resistance. Compare the reading to the original readings from the manufacturer. If the measurements are within tolerance, proceed to 5. If the readings are not within tolerance, proceed to 4.
Disconnect the leads from the terminals of the magnet. Take a reading directly from the terminals of the magnet. If the readings are now within tolerance, replace the leads of the magnet. If the readings are not within tolerance, replace the magnet.
Connect the two leads from the megohmmeter to two clean areas of the housing of the magnet. Take a reading. The resistance reading should be zero. If the reading is not zero, place the leads in a different place and measure the resistance again. Once you have obtained a zero reading on the megohmmeter, remove one of the leads and attach the lead to one terminal of the magnet. Make sure that the other lead is not touching the magnet or any metal. Take a resistance reading. If the reading is above 0.05 megohm, the magnet is within tolerance. If the reading is below 0.05 megohm, replace the magnet.
Caterpillar parts catalog:
Parts pump Caterpillar catalog:
4559752
PUMP GP-GEAR
Caterpillar
Caterpillar
4559746
PUMP GP-GEAR
Caterpillar
Caterpillar
4465137
PUMP GP-ELECTRIC DRIVE
Caterpillar
Caterpillar
4308378
PUMP GP-GEAR
Caterpillar
Caterpillar
4304142
PUMP & MOUNTING GP
Caterpillar
Caterpillar
4197581
PUMP GP-FUEL INJECTION
Caterpillar
Caterpillar
4889400
PUMP & MOUNTING GP
Caterpillar
Caterpillar
4846957
PUMP GP-GEAR
Caterpillar
Caterpillar
4683588
PUMP & MOUNTING GP
Caterpillar
Caterpillar
4675122
PUMP GP-PISTON
Caterpillar
Caterpillar
4649185
PUMP & MOUNTING GP
Caterpillar
Caterpillar
4614342
PUMP GP-PISTON
Caterpillar
Caterpillar