4P3801 PUMP KIT-WATER Caterpillar parts
Rating:
Alternative (cross code) number:
CA4P3801
4P-3801
4P3801
CA4P3801
4P-3801
4P3801
Weight: 0.02 pounds 0 kg.
Information:
Illustration 1 g01217615
Schematic of transmission solenoid 3This diagnostic code is associated with transmission solenoid 3. The FMI 03 means that the Power Train ECM has determined that the voltage of the solenoid circuit is above normal. The possible causes of the diagnostic code are:
The solenoid has failed.
The energize circuit of the solenoid is shorted to the +battery circuit.
The ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1403 FMI 03 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:When this diagnostic code occurs, only the gears that use the solenoids that have faults are not available.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO THE +BATTERY CIRCUIT
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the ECM.
At the machine harness connector for the ECM, measure the resistance from contact J1-66 (wire 754-BU) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5 ohms. Results:
YES - Each resistance measurement is greater than 5 ohms. The machine harness is correct. Proceed to Test Step 2.
NO - Each resistance measurement is not greater than 5 ohms. There is a short in the machine harness. The short is between J1-66 (754-BU) and the circuit that has the low resistance measurement. Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 1403 FMI 03 is active.Expected Result:The CID 1403 FMI 03 is active.Results:
YES - The CID 1403 FMI 03 is active. The problem has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. Refer to Troubleshooting, Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
NO - The CID 1403 FMI 03 is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP
Parts pump Caterpillar catalog:
4P2709
PUMP AS-F INJ
Caterpillar
Caterpillar
4P1559
PUMP G
Caterpillar
Caterpillar
4N9911
PUMP G-
Caterpillar
Caterpillar
4N9830
PUMP G GOV &
Caterpillar
Caterpillar
4N9650
PUMP G GOV &
Caterpillar
Caterpillar
4N8829
PUMP G GOV &
Caterpillar
Caterpillar
4P5274
PUMP GP
Caterpillar
Caterpillar
4P4842
PUMP AS-OIL
Caterpillar
Caterpillar
4P4841
PUMP AS-OIL
Caterpillar
Caterpillar
4P4755
PUMP AS-OIL
Caterpillar
Caterpillar
4P4212
PUMP AS
Caterpillar
Caterpillar
4P3802
PUMP AS
Caterpillar
Caterpillar