Information:
Before using the machine with remote control do a walk around inspection. Check levels of oil and water and check for leaks and damage.Operate the machine manually to ensure that all controls operate normally and the brakes operate effectively.When the machine is in remote control mode, always ensure that nobody is near the machine or in the machine operating area.Under no circumstances should any service work or Testing and Adjusting be carried out on the machine while the machine is operating in remote control.
Park the machine in a convenient and safe location to start remote control operation.
Engage the parking brake on the machine.
Lower all implements to the ground. Activate the hydraulic lockout switch.
Place the key switch of the machine in the OFF position to shut down the engine.
Illustration 1 g03054099
(36) Manual override switch
Confirm that the manual override switch (36) is in the remote position.
Illustration 2 g03389440
Ground Level Service Center (GLSC) (31) Manual/remote mode switch (32) Access ladder switch (Optional function) (33) Delayed lighting switch (not available for RJG, GEB, TPB) (34) Engine shutdown switch (35) Lock out tab
Do not attempt to access the ground level service center when the machine is in motion. Serious injury or death may occur. Place the implements on the ground and apply the parking brake before accessing the ground level service center.
Proceed to the Ground Level Service Center at the rear of the machine.
Confirm that the Engine Shutdown switch (34) is in REMOTE position (pulled out).
Place the Manual/Remote Mode switch (31) in REMOTE position.Note: The blue indicator light on top of the machine will now be solid blue.Preliminary Remote Console Checks
Illustration 3 g02928076
(14) Implement select switch (15) Blade float indicator (16) Operator console power switch (17) Horn button (18) Implement lockout switch (19) Auto blade assist/autocarry or autorip enable switch (20) Single/dual blade tilt switch (21) High-idle engine speed select dial (22) Machine light switch (23) Bidirectional/enhanced auto shift switch (24) Auto kickdown switch (25) Machine power/engine crank switch (26) Operator console commanded stop switch (27) Parking brake switch
Take note of the area around the machine and walk to the side of the machine about 15 m (50 ft) away.
Confirm that the Commanded Stop switch (26) on the remote console is turned off, turn the switch in the clockwise direction in order to disengage.
Turn the following switches to the default position.
"IMPLEMENT LOCKOUT" (18) ON
"PARKING BRAKE" (27) ON
"MACHINE POWER/ENGINE CRANK" (25) OFF
"IMPLEMENTS CONTROL" (13) CENTER
"STEERING / DIRECTION CONTROL" (4) CENTERNote: The default positions of these switches are noted by yellow icons.
Make sure that the operator console is upright.Note: The operator console has a built-in inclinometer which prevents operation when the console is tilted past 60 degrees in any direction.
Turn the operator console power switch (16) to the "ON" position in order to power on the operator console. The Commanded Stop LED (51) will blink slowly. Then, the Status Display LCD will show three dashes that signify that the radios have not established a link.
Quickly cycle the Commanded Stop switch (26) from on
Park the machine in a convenient and safe location to start remote control operation.
Engage the parking brake on the machine.
Lower all implements to the ground. Activate the hydraulic lockout switch.
Place the key switch of the machine in the OFF position to shut down the engine.
Illustration 1 g03054099
(36) Manual override switch
Confirm that the manual override switch (36) is in the remote position.
Illustration 2 g03389440
Ground Level Service Center (GLSC) (31) Manual/remote mode switch (32) Access ladder switch (Optional function) (33) Delayed lighting switch (not available for RJG, GEB, TPB) (34) Engine shutdown switch (35) Lock out tab
Do not attempt to access the ground level service center when the machine is in motion. Serious injury or death may occur. Place the implements on the ground and apply the parking brake before accessing the ground level service center.
Proceed to the Ground Level Service Center at the rear of the machine.
Confirm that the Engine Shutdown switch (34) is in REMOTE position (pulled out).
Place the Manual/Remote Mode switch (31) in REMOTE position.Note: The blue indicator light on top of the machine will now be solid blue.Preliminary Remote Console Checks
Illustration 3 g02928076
(14) Implement select switch (15) Blade float indicator (16) Operator console power switch (17) Horn button (18) Implement lockout switch (19) Auto blade assist/autocarry or autorip enable switch (20) Single/dual blade tilt switch (21) High-idle engine speed select dial (22) Machine light switch (23) Bidirectional/enhanced auto shift switch (24) Auto kickdown switch (25) Machine power/engine crank switch (26) Operator console commanded stop switch (27) Parking brake switch
Take note of the area around the machine and walk to the side of the machine about 15 m (50 ft) away.
Confirm that the Commanded Stop switch (26) on the remote console is turned off, turn the switch in the clockwise direction in order to disengage.
Turn the following switches to the default position.
"IMPLEMENT LOCKOUT" (18) ON
"PARKING BRAKE" (27) ON
"MACHINE POWER/ENGINE CRANK" (25) OFF
"IMPLEMENTS CONTROL" (13) CENTER
"STEERING / DIRECTION CONTROL" (4) CENTERNote: The default positions of these switches are noted by yellow icons.
Make sure that the operator console is upright.Note: The operator console has a built-in inclinometer which prevents operation when the console is tilted past 60 degrees in any direction.
Turn the operator console power switch (16) to the "ON" position in order to power on the operator console. The Commanded Stop LED (51) will blink slowly. Then, the Status Display LCD will show three dashes that signify that the radios have not established a link.
Quickly cycle the Commanded Stop switch (26) from on
Parts pump Caterpillar catalog:
5387298
PUMP GP-
Caterpillar
Caterpillar
5383706
PUMP GP-F XFR
Caterpillar
Caterpillar
5381877
PUMP
Caterpillar
Caterpillar
5381024
PUMP
Caterpillar
Caterpillar
5380993
PUMP
Caterpillar
Caterpillar
5380957
PUMP
Caterpillar
Caterpillar
5398391
PUMP GP-
Caterpillar
Caterpillar
5396362
PUMP GP-
Caterpillar
Caterpillar
5393389
PUMP GP-MTG& -
Caterpillar
Caterpillar
5392726
PUMP GP-F PRM
Caterpillar
Caterpillar
5392722
PUMP GP-F PRM
Caterpillar
Caterpillar
5388410
PUMP GP-26
Caterpillar
Caterpillar