6N1813 PUMP GP-FUEL TRANSFER Caterpillar parts
594H, D9H
Rating:
Alternative (cross code) number:
CA6N1813
6N-1813
6N1813
CA6N1813
6N-1813
6N1813
Weight: 14 pounds 6 kg.
PIPELAYER, TRACK-TYPE TRACTOR,
Related part:
6N1813
PUMP GP-FT-YM
3309279
CL
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$264.07
17 Aug 2022
Amazon.com
6N1813 Fuel Pump 4M9275 - Fits: D9H
CGR Compatible Models - D9H || Related Items - 7b0305 8h4827 || Interchange - 3309279 || fuel transfer pump gp
CGR Compatible Models - D9H || Related Items - 7b0305 8h4827 || Interchange - 3309279 || fuel transfer pump gp
Information:
Table 1
OP10 Setpoints (1) - AC Offset Adjustment    
Setpoint     Name     Description     Range Of Value     Factory Default    
PH A     Phase A Voltage Adjustment     Value used by the GSC in order to offset the voltmeter (for the phase A to neutral reading) from the actual voltage measurement.     -5.0% to +5.0% of measured voltage in increments of 0.04%     0    
PH B     Phase B Voltage Adjustment     Value used by the GSC to offset the voltmeter (for the phase B to neutral reading) from the actual voltage measurement.     -5.0% to +5.0% of measured voltage in increments of 0.04%     0    
PH C     Phase C Voltage Adjustment     Value used by the GSC to offset the voltmeter (for the phase C to neutral reading) from the actual voltage measurement.     -5.0% to +5.0% of measured voltage in increments of 0.04%     0    
PH A-B     Phase A-B Voltage Adjustment     Value used by the GSC to offset the voltmeter (for the phase A to phase B reading) from the actual voltage measurement.     -5.0% to +5.0% of measured voltage in increments of 0.04%     0    
PH B-C     Phase B-C Voltage Adjustment     Value used by the GSC to offset the voltmeter (for the phase B to phase C reading) from the actual voltage measurement.     -5.0% to +5.0% of measured voltage in increments of 0.04%     0    
PH C-A     Phase C-A Voltage Adjustment     Value used by the GSC to offset the voltmeter (for the phase C to phase A reading) from the actual voltage measurement.     -5.0% to +5.0% of measured voltage in increments of 0.04%     0    
( 1 ) The setpoints are programmed to the default value at the factory. The setpoints may be changed in order to satisfy the customer requirements or the application requirements.OP10 is the option for adjusting the voltmeter readings of the GSC. This adjustment may be necessary when generator sets are operated in parallel. The GSC AC voltage measurements are calibrated at the factory. An accurate standard is used. However, when two generator sets are paralleled, the application may require the paralleled generator sets to have exactly the same voltage value. The AC offset of one GSC is changed to match the voltage value of another generator set. Note: It is NOT recommended that the AC offset be altered under any other circumstances. Performing this procedure takes the GSC out of factory calibration. Procedure For Voltmeter Offset Adjustment
The paralleled generator sets must be running at rated speed. The generator sets can then have the voltage adjustment made. Note: Service mode cannot be entered when the ECS is in the AUTO position.
Enter service mode on the GSC that is being adjusted. Enter the password. "OP 1" is showing on lower display. For more information, see the Systems Operation, "Password Entry OP3".
Press "SCROLL UP" key nine times. "OP 10" is showing on the lower display.
Press "SELECT"
Caterpillar SIS machinery equipment:
Caterpillar SIS
D353 VEHICULAR ENGINE 12U00001-UP (MACHINE) »
6N-1813
PUMP GP-FUEL TRANSFER
D9H TRACTOR / POWER SHIFT / 90V04940-UP (MACHINE) POWERED BY D353 ENGINE »
6N-1813
PUMP GP-FUEL TRANSFER
D9H TRACTOR / POWER SHIFT / 90V04940-UP (MACHINE) POWERED BY D353 ENGINE »
6N-1813
PUMP GP-FUEL TRANSFER
594H PIPELAYER / POWER SHIFT / 96V00255-UP (MACHINE) POWERED BY D353 ENGINE »
6N-1813
PUMP GP-FUEL TRANSFER
594H PIPELAYER / POWER SHIFT / 96V00255-UP (MACHINE) POWERED BY D353 ENGINE »
6N-1813
PUMP GP-FUEL TRANSFER
D9H TRACTOR 90V00001-UP (MACHINE) POWERED BY D353 ENGINE »
6N-1813
FUEL TRANSFER PUMP GROUP
D9H TRACTOR - ARRANGEMENT 1Z434 / POWER SHIFT / 90V07190-UP (MACHINE) POWERED BY D353 ENGINE »
6N-1813
PUMP GP-FUEL TRANSFER
594H PIPELAYER - ARRANGEMENT 1Z420 / POWER SHIFT / 96V00385-UP (MACHINE) POWERED BY D353 ENGINE »
6N-1813
PUMP GP-FUEL TRANSFER
Caterpillar parts catalog:
Parts pump Caterpillar catalog:
1P2187
PUMP GP-GEAR
57, 58, 594H, D7G, D9H
57, 58, 594H, D7G, D9H
9P1832
PUMP GP-GEAR
571G, D7G, D8K, D9H
571G, D7G, D8K, D9H
2P9239
PUMP GP-GEAR
571G, 572G, 583K, 594H, D7F, D7G, D8K, D9H
571G, 572G, 583K, 594H, D7F, D7G, D8K, D9H
6n6424
PUMP GP-WATER
594H, D9H
594H, D9H
3G6002
PUMP GP-GEAR
193, D9H
193, D9H
3P4405
PUMP GP-TRANSMISSION GEAR
583K, 594H, D8K, D9H
583K, 594H, D8K, D9H
2P2110
PUMP GP-GEAR
58, 594H, D9H
58, 594H, D9H
7s7400
PUMP GP-SCAVENGE & CIRCULATING
583K, 594, 594H, D8H, D8K, D9G, D9H
583K, 594, 594H, D8H, D8K, D9G, D9H
6N2450
PUMP GP-OIL
594H, D9H
594H, D9H
8S2706
PUMP GP-FUEL PRIMING
594, 594H, D9G, D9H
594, 594H, D9G, D9H
2S7264
PUMP ASSEMBLY FUEL VALVE
594H, D353C, D379A, D379B, D398, D398A, D398B, D399, D9G, D9H
594H, D353C, D379A, D379B, D398, D398A, D398B, D399, D9G, D9H
8N0490
PUMP ASSEM.
963, 973, 992C, D10, D9H
963, 973, 992C, D10, D9H
8S2706
PUMP GP-FUEL PRIMING
594, 594H, D9G, D9H
594, 594H, D9G, D9H
6N2450
PUMP GP-OIL
594H, D9H
594H, D9H
6N5722
PUMP GP-OIL
641B, 650B, 657B, 666B, 772, 773, D346
641B, 650B, 657B, 666B, 772, 773, D346
1P7898
PUMP GP-FUEL PRIMING
772, 773
772, 773
1066598
PUMP GROUP-VANE BASIC
561H, 561M
561H, 561M
9H2256
PUMP ASSEMBLY
120, 12E, 12F, 140, 14E, 1673, 1673B, 1673C, 1674, 1676, 3160, 3304, 3306, 561B, 561C, 627, 637, 814, 815, 816, 920, 930, 941, 950, 951B, 955H, 955K, 955L, 966C, 977H, 977K, 977L, 980B, D320A, D330A, ...