7I8264 PUMP GP-DOUBLE-PISTON Caterpillar parts
311
Rating:
Alternative (cross code) number:
CA7I8264
7I-8264
7I8264
CA7I8264
7I-8264
7I8264
Weight: 190 pounds 86 kg.
Information:
GROOVE WIDTH
18
mm
ID/WIDTH
143
mm
LARGER OD
173
mm
RADIUSED CHAMFER
Y
SMALLER OD
143
mm
SPLIT
N
THICKNESS
30
mm
EXCAVATOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 7I8264:
Information:
Place the multimeter on the "200 ohm" scale. Touch the meter leads between field winding leads (1).
Touch the meter leads between each field winding lead (1) and motor terminal lead (2).
Each reading should be 00.0 to 00.1 ohms.
If the meter reading is higher than the meter reading in 3, there is an open in the field winding. The case of the starting motor and the field windings must be replaced. Armature Short Circuit - Test
Illustration 3 g00584876
Armature Short Circuit Check (3) Armature. (4) Growler tester.
Place armature (3) on growler tester (4). The tester needs to be turned to the ON position.
Hold a hacksaw blade against the armature core. Slowly rotate the armature while the blade is against the core.
The blade should not vibrate or the blade should not be attracted to the armature core.
If the blade vibrates or the blade is attracted to the core, the armature has a short. The armature must be rebuilt or replaced. Armature Ground - Test
Illustration 4 g00584879
Armature Winding Ground Test (3) Armature.
Place the multimeter in the "20M" position. Touch one meter lead on each commutator bar and the other lead on the armature core.
Each multimeter reading should be greater than 100,000 ohms. A meter reading of "0.10" or a value that is greater is acceptable.
If the meter reading is lower than 100,000 ohms, the armature is grounded. The armature must be rebuilt or replaced. Armature Continuity - TestSpecial equipment is needed to test the armature for an open. If the commutator is pitted or the bars are burned, the armature has an open. The armature must be replaced.Armature Runout - Check
Illustration 5 g00584880
Armature Runout Check (5) Commutator.
Check the runout of the armature (TIR) of the commutator (5). The maximum TIR that is allowed is 0.05 mm (0.0020 inch).
If the TIR is too great, the armature must be replaced. Commutator Outside Diameter - Check
Illustration 6 g00584882
Commutator Outside Diameter Check (5) Commutator.
Check the outside diameter of commutator (5). The new diameters of the commutator and the minimum diameters of the commutator are provided in the Specifications section.
If the armature is worn, the armature must be replaced.
Illustration 7 g00584885
Depth Of Segment Mica (X) Depth of segment mica.
Measure the depth of commutator segment mica. The minimum depth should be 0.20 mm (0.008 inch).
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
If the depth is under the minimum, the mica can be undercut. If the mica is undercut, remove all shavings and mica particles. Brush Holder - Test
Illustration 8 g00584915
Brush Holder Insulation Test (6) Brush holder plate. (7) Brush holder. (8) Brush spring.
Check the brush holder springs (8) for damage or rust. If necessary, replace the brush holder springs.
Place the multimeter in the "20M" position. Touch one meter lead to each positive brush holder (7) and the other lead to brush holder plate (6). Check both positive brush holders.
Each multimeter reading should be greater than 100,000 ohms. A meter reading of "0.10" or a value that is greater is acceptable.
If the meter
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts pump Caterpillar catalog:
5I7773
PUMP GP-WATER
311, 312
311, 312
7I0149
PUMP GP-MAIN & SWING
311, 312
311, 312
4I1023
PUMP GP-GEAR
311, 311B, 312, 312B, 312B L, 315, 315B, 315B FM L, 315B L, 317, 317B LN, 318B, 320 L
311, 311B, 312, 312B, 312B L, 315, 315B, 315B FM L, 315B L, 317, 317B LN, 318B, 320 L
1252989
PUMP ASSEM.
311, 311B, 312B, 320B, 320N, 321B
311, 311B, 312B, 320B, 320N, 321B
5I7507
PUMP AS (D. K. C)
311, 320 L, 320B
311, 320 L, 320B
5I7693
PUMP AS
311, 320 L
311, 320 L
7I7667
PUMP GP-MOUNTING &
320, 320N
320, 320N
1376383
PUMP GP-FUEL INJECTION
315, 315B, 315B FM L
315, 315B, 315B FM L
7I1902
PUMP AR
322
322