Information:
Illustration 1 g01984293
Schematic of the "Hydraulic Pilot Supply Solenoid 2"This diagnostic code is associated with the "Hydraulic Pilot Supply" Solenoid. The FMI 03 diagnostic code means that the ECM has determined that the voltage of the solenoid circuit is above normal. The possible causes of the diagnostic code are listed below:
The solenoid has failed.
The energize circuit of the solenoid is shorted to the +battery circuit.
The ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0358 FMI 03 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:The implement system will operate at half speed. When the key start switch is in the ON position and the engine is dead, the lift linkage may drift more than normal.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the ECM.
At the machine harness connector for the ECM, measure the resistance from contact J1-12 (wire H717-BR) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J1-12 (H717-BR) and the circuit that has a low resistance measurement. Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 0358 FMI 03 diagnostic code is active.Expected Result:The CID 0358 FMI 03 diagnostic code is active.Results:
YES - The CID 0358 FMI 03 diagnostic code is active. The problem has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
NO - The CID 0358 FMI 03 diagnostic code is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP
Caterpillar parts catalog:
Parts pump Caterpillar catalog:
4319585
PUMP GP-METERING
621K, 623K, 623K LRC, 627K, 627K LRC
621K, 623K, 623K LRC, 627K, 627K LRC
4450501
PUMP GP-GEAR
621K, 623K, 623K LRC, 627K, 627K LRC
621K, 623K, 623K LRC, 627K, 627K LRC
10R3797
PUMP GP-FUEL INJECTION
627B, 627E
627B, 627E
10R3799
PUMP GP-GOV & FUEL INJ
637D, 637E
637D, 637E
2837604
PUMP AS-WATER
924H, BA30, BP22
924H, BA30, BP22
7J7971
PUMP ASSEM.
627, 657B
627, 657B
9D2628
PUMP
631C
631C
8J0419
PUMP GROUP
627, 657B
627, 657B
8J0437
PUMP GROUP
627, 627B
627, 627B
1T0919
PUMP
613
613
6J8200
PUMP ASSEM.
637, 641, 657
637, 641, 657