8N9030 PUMP GP-WATER Caterpillar parts
3304, 3306
Rating:
Alternative (cross code) number:
CA8N9030
8N-9030
8N9030
CA8N9030
8N-9030
8N9030
Weight: 28 pounds 12 kg.
INDUSTRIAL ENGINE,
Information:
an ECM, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the ECM must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace". Repeat the check of the Diagnostic Codes.STOPTest Step 28. CHECK THE VOLTAGE
Set the digital multimeter to the scale for VDC.
At the Lift Relay SSR 170, connect the positive lead of the multimeter to Terminal 3 (Wire G890-PU). Connect the negative lead of the multimeter to Terminal 4 (Wire 299-BK). Refer to the Electrical System Schematic, KENR8247.
Measure the voltage after the lift switch is pressed.Expected Result:The voltage measurement is battery voltage.Results:
YES - The voltage measurement is battery voltage. Proceed to Test Step 29.
NO - The voltage does not measure battery voltage.Repair: The wiring connecting the Lift Relays (SSR 170, SSR 171) and the ECM has failed. Wire (G890-PU) or Wire (299-BK) has failed. Repair or replace the failed wire.STOPTest Step 29. CHECK THE VOLTAGE
Set the digital multimeter to the scale for VDC.
At the Lift Relay SSR 171, connect the positive lead of the multimeter to Terminal 3 (Wire G890-PU). Connect the negative lead of the multimeter to Terminal 4 (Wire 299-BK). Refer to the Electrical System Schematic, KENR8247.
Measure the voltage after the lift switch is pressed.Expected Result:The voltage measurement is battery voltage.Results:
YES - The voltage measurement is battery voltage. Proceed to Test Step 30.
NO - The voltage does not measure battery voltage. The ECM may have failed.Repair: The wiring connecting the Lift Relays (SSR 170, SSR 171) and the ECM has failed. Wire (G890-PU) or Wire (299-BK) has failed. Repair or replace the failed wire.STOPTest Step 30. CHECK THE SSR 170 RELAY
Turn the Keyswitch and the Disconnect switch to the ON position.
Set the digital multimeter to the selection for resistance.
At the Lift Relay SSR 170, connect the positive lead of the multimeter to Terminal 1 (Wire 103-YL). Connect the negative lead of the multimeter to Terminal 2 (Wire 115-RD). Refer to the Electrical System Schematic, KENR8247
Press the "Lift" switch.
Measure the resistance with the Lift switch pressed.Expected Result:The resistance measures 0 to 2 ohms.Results:
YES - The resistance measures 0 to 2 ohms. Proceed to Test Step 31.
NO - The resistance does not measure 0 to 2 ohms.Repair: The SSR 170 Lift Relay has failed. Replace the Relay.STOPTest Step 31. CHECK THE SSR 171 RELAY
The Keyswitch and the Disconnect switch remain in the ON position.
Set the digital multimeter to the selection for resistance.
At the Lift Relay SSR 171, connect the positive lead of the multimeter to Terminal 1 (Wire 111-RD). Connect the negative lead of the multimeter to Terminal 2 (Wire 205-BK). Refer to the Electrical System Schematic, KENR8247.
Press the "Lift" switch.
Measure the resistance with the Lift switch pressed.Expected Result:The resistance measures 0 to 2 ohms.Results:
YES - The resistance measures 0 to 2 ohms. Proceed to Test Step 32.
NO - The resistance does not measure 0 to 2 ohms.Repair: The SSR 171 Lift Relay has failed. Replace the Relay.STOPTest Step 32. CHECK FOR AN
Set the digital multimeter to the scale for VDC.
At the Lift Relay SSR 170, connect the positive lead of the multimeter to Terminal 3 (Wire G890-PU). Connect the negative lead of the multimeter to Terminal 4 (Wire 299-BK). Refer to the Electrical System Schematic, KENR8247.
Measure the voltage after the lift switch is pressed.Expected Result:The voltage measurement is battery voltage.Results:
YES - The voltage measurement is battery voltage. Proceed to Test Step 29.
NO - The voltage does not measure battery voltage.Repair: The wiring connecting the Lift Relays (SSR 170, SSR 171) and the ECM has failed. Wire (G890-PU) or Wire (299-BK) has failed. Repair or replace the failed wire.STOPTest Step 29. CHECK THE VOLTAGE
Set the digital multimeter to the scale for VDC.
At the Lift Relay SSR 171, connect the positive lead of the multimeter to Terminal 3 (Wire G890-PU). Connect the negative lead of the multimeter to Terminal 4 (Wire 299-BK). Refer to the Electrical System Schematic, KENR8247.
Measure the voltage after the lift switch is pressed.Expected Result:The voltage measurement is battery voltage.Results:
YES - The voltage measurement is battery voltage. Proceed to Test Step 30.
NO - The voltage does not measure battery voltage. The ECM may have failed.Repair: The wiring connecting the Lift Relays (SSR 170, SSR 171) and the ECM has failed. Wire (G890-PU) or Wire (299-BK) has failed. Repair or replace the failed wire.STOPTest Step 30. CHECK THE SSR 170 RELAY
Turn the Keyswitch and the Disconnect switch to the ON position.
Set the digital multimeter to the selection for resistance.
At the Lift Relay SSR 170, connect the positive lead of the multimeter to Terminal 1 (Wire 103-YL). Connect the negative lead of the multimeter to Terminal 2 (Wire 115-RD). Refer to the Electrical System Schematic, KENR8247
Press the "Lift" switch.
Measure the resistance with the Lift switch pressed.Expected Result:The resistance measures 0 to 2 ohms.Results:
YES - The resistance measures 0 to 2 ohms. Proceed to Test Step 31.
NO - The resistance does not measure 0 to 2 ohms.Repair: The SSR 170 Lift Relay has failed. Replace the Relay.STOPTest Step 31. CHECK THE SSR 171 RELAY
The Keyswitch and the Disconnect switch remain in the ON position.
Set the digital multimeter to the selection for resistance.
At the Lift Relay SSR 171, connect the positive lead of the multimeter to Terminal 1 (Wire 111-RD). Connect the negative lead of the multimeter to Terminal 2 (Wire 205-BK). Refer to the Electrical System Schematic, KENR8247.
Press the "Lift" switch.
Measure the resistance with the Lift switch pressed.Expected Result:The resistance measures 0 to 2 ohms.Results:
YES - The resistance measures 0 to 2 ohms. Proceed to Test Step 32.
NO - The resistance does not measure 0 to 2 ohms.Repair: The SSR 171 Lift Relay has failed. Replace the Relay.STOPTest Step 32. CHECK FOR AN
Caterpillar SIS machinery equipment:
Parts pump Caterpillar catalog:
6i1346
PUMP GP-ENGINE OIL
120G, 12G, 12H, 12H ES, 12H NA, 130G, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 215D, 219D, 225D, 229D, 235B, 235C, 235D, 330, 330 FM L, 330 L, 3304, 3304...
120G, 12G, 12H, 12H ES, 12H NA, 130G, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 215D, 219D, 225D, 229D, 235B, 235C, 235D, 330, 330 FM L, 330 L, 3304, 3304...
1727760
PUMP GP-WATER
330, 3304, 3304B, 3306, 3306B, 3306C, 330B L, 350, 517, 527, 545, 611, 615C, 966F, 966F II, CB-534, D4H, D4HTSK III, D6D, D6G2 XL, D6H, D7G, D7H, G3304B, G3306B, R1300, R1300G
330, 3304, 3304B, 3306, 3306B, 3306C, 330B L, 350, 517, 527, 545, 611, 615C, 966F, 966F II, CB-534, D4H, D4HTSK III, D6D, D6G2 XL, D6H, D7G, D7H, G3304B, G3306B, R1300, R1300G
6N7606
PUMP GP-GOV & FUEL INJ
1673C, 3306
1673C, 3306
4N4314
PUMP GP-FUEL PRIMING
140B, 1673C, 225, 225D, 227, 229, 231D, 3116, 3126, 3208, 3304, 3306, 518, 528, 571G, 572G, 613C, 627B, 637D, 639D, 814, 815, 816, 910, 920, 930, 931B, 931C, 931C II, 935B, 935C, 935C II, 950, 966C, 9...
140B, 1673C, 225, 225D, 227, 229, 231D, 3116, 3126, 3208, 3304, 3306, 518, 528, 571G, 572G, 613C, 627B, 637D, 639D, 814, 815, 816, 910, 920, 930, 931B, 931C, 931C II, 935B, 935C, 935C II, 950, 966C, 9...
4W2448
PUMP GP-ENGINE OIL
120G, 12G, 130G, 140G, 14G, 160G, 215B, 215C, 215D, 219D, 225, 225D, 229, 229D, 235, 235B, 235C, 3304, 3304B, 3306, 3306B, 518, 528, 561D, 571G, 572G, 615, 615C, 621E, 621R, 627B, 627E, 637D, 637E, 65...
120G, 12G, 130G, 140G, 14G, 160G, 215B, 215C, 215D, 219D, 225, 225D, 229, 229D, 235, 235B, 235C, 3304, 3304B, 3306, 3306B, 518, 528, 561D, 571G, 572G, 615, 615C, 621E, 621R, 627B, 627E, 637D, 637E, 65...
2W8001
PUMP GP-WATER
120B, 140B, 215C, 215D, 219D, 225D, 229, 229D, 235, 235B, 235C, 330, 330 FM L, 330 L, 3304, 3304B, 3306, 3306B, 350, 515, 525, 527, 561D, 571G, 572G, 627B, 627E, 627F, 637D, 637E, 639D, 65, 65C, 70C, ...
120B, 140B, 215C, 215D, 219D, 225D, 229, 229D, 235, 235B, 235C, 330, 330 FM L, 330 L, 3304, 3304B, 3306, 3306B, 350, 515, 525, 527, 561D, 571G, 572G, 627B, 627E, 627F, 637D, 637E, 639D, 65, 65C, 70C, ...
9H2256
PUMP ASSEMBLY
120, 12E, 12F, 140, 14E, 1673, 1673B, 1673C, 1674, 1676, 3160, 3304, 3306, 561B, 561C, 627, 637, 814, 815, 816, 920, 930, 941, 950, 951B, 955H, 955K, 955L, 966C, 977H, 977K, 977L, 980B, D320A, D330A, ...
120, 12E, 12F, 140, 14E, 1673, 1673B, 1673C, 1674, 1676, 3160, 3304, 3306, 561B, 561C, 627, 637, 814, 815, 816, 920, 930, 941, 950, 951B, 955H, 955K, 955L, 966C, 977H, 977K, 977L, 980B, D320A, D330A, ...
1550067
PUMP GP-WATER
3304, 3304B, 3306, 3306B, 515, 525, 530B
3304, 3304B, 3306, 3306B, 515, 525, 530B
1052508
PUMP AS-FUEL PRIMING
120G, 12G, 12H, 12H ES, 12H NA, 140H, 140H ES, 140H NA, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 163H, 163H NA, 16G, 16H, 16H NA, 214B, 235, 3114, 3116, 3126, 3126B, 3126E, 3176, 3176B, 3176C, 3196,...
120G, 12G, 12H, 12H ES, 12H NA, 140H, 140H ES, 140H NA, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 163H, 163H NA, 16G, 16H, 16H NA, 214B, 235, 3114, 3116, 3126, 3126B, 3126E, 3176, 3176B, 3176C, 3196,...
1375541
PUMP GP-FUEL PRIMING
120G, 12G, 130G, 140G, 140H, 143H, 14G, 14H, 160G, 160H, 163H, 1673C, 16H, 235B, 24H, 3116, 311C, 311D LRR, 3126, 3126B, 3126E, 312C, 312C L, 312D, 312D L, 313D, 314C, 314D CR, 314D LCR, 315C, 315D L,...
120G, 12G, 130G, 140G, 140H, 143H, 14G, 14H, 160G, 160H, 163H, 1673C, 16H, 235B, 24H, 3116, 311C, 311D LRR, 3126, 3126B, 3126E, 312C, 312C L, 312D, 312D L, 313D, 314C, 314D CR, 314D LCR, 315C, 315D L,...
4W0788
PUMP AS-FUEL PRIMING
14G, 205B, 215B, 224B, 235, 245, 3114, 3116, 320 L, 330 L, 3304, 3304B, 3306, 3306B, 350, 3516, 375, 446, 528, 572G, 621, 910E, 920, 926, 936F, 943, 950B, 950F, 953, 953C, 966F, 980C, 980F, C-12, C12,...
14G, 205B, 215B, 224B, 235, 245, 3114, 3116, 320 L, 330 L, 3304, 3304B, 3306, 3306B, 350, 3516, 375, 446, 528, 572G, 621, 910E, 920, 926, 936F, 943, 950B, 950F, 953, 953C, 966F, 980C, 980F, C-12, C12,...
1W3010
PUMP AS-FUEL INJECTION
3208, 3306, 613C, PR-1000
3208, 3306, 613C, PR-1000
1W6602
PUMP GP-WATER
3304, 3306
3304, 3306
1U3371
PUMP GP-GEAR
992C
992C
8J5892
PUMP GP-GEAR
992, 992C
992, 992C
3G2848
PUMP GP-PISTON
992C, 992D, 994
992C, 992D, 994
9J6484
PUMP GP-GEAR
992C
992C