1W4557 RADIATOR GP Caterpillar parts
936, CS-643
Rating:
Alternative (cross code) number:
CA1W4557
1W-4557
1W4557
CA1W4557
1W-4557
1W4557
VIBRATORY COMPACTOR, WHEEL LOADER,
Information:
Illustration 1 g00797260
Schematic of the Retract Solenoid Valve for Auxiliary Stem 2This diagnostic code is associated with the retract solenoid valve for auxiliary stem 2. This diagnostic code is recorded when the implement ECM reads the current of the solenoid as being below normal. There is an open circuit.The possible causes of this diagnostic code are listed:
The signal circuit of the solenoid is open.
The return circuit of the solenoid is open.
The solenoid has failed.
The implement ECM has failed. This is unlikely. System Response:When this diagnostic code occurs, there is no warning on the monitor. The diagnostic code will only be active when the control for the work tool is actuated. An example of this action is pressing the pedal for operating a hammer. The diagnostic code is active when the pedal is pressed. When the pedal is no longer pressed, the diagnostic code is not active, but the code is present in the diagnostic code log ("LOGGED ERROR" screen). Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code is corrected.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Disconnect the solenoid with the diagnostic code from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire K861-GN) to wire (K868-BR).
Determine if CID 1597 FMI 05 is present. Check the "ACTIVE ERROR" screen on the monitor.Expected Result:The diagnostic code is not active when the jumper wire is installed. Results:
YES - The diagnostic code is not active when the jumper wire is installed. The circuit is correct. Repair: The solenoid has failed. Repeat this test step "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem.STOP
NO - The diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to test step 2.Test Step 2. CHECK THE HARNESS FOR AN OPEN.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the CONN189 and CONN190 machine harness connectors from the implement ECM.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire K861-GN) to contact 2 (wire K868-BR).
At the machine harness connector for the ECM, measure the resistance from signal contact CONN190-29 (wire K861-GN) to contact CONN190-39 (wire K868-BR) (return wire).Expected Result:The resistance should be less than 5.0 ohms.Results:
OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to test step 3.
NOT OK - The resistance is greater than 5.0 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.Repair: The open is in wire (K861-GN) or in wire (K868-BR) of the machine harness. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors and clean the contacts of the harness connectors.
Reconnect
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts radiator Caterpillar catalog:
3436084
RADIATOR & HYD OIL COOLER GP
CB-44B, CB-54B
CB-44B, CB-54B
3566906
RADIATOR GP
CW-14
CW-14
2955839
RADIATOR GP
CB-22
CB-22
2932058
RADIATOR GP
CB-22
CB-22
1846099
RADIATOR AR
D11R
D11R
2107998
RADIATOR GP
330C, 330C FM, 330C L, 330C MH
330C, 330C FM, 330C L, 330C MH
3870515
RADIATOR & HYD OIL COOLER GP
CS-74B, CS-78B
CS-74B, CS-78B