2256360 RADIATOR GP Caterpillar parts
834H
Rating:
Alternative (cross code) number:
CA2256360
225-6360
2256360
CA2256360
225-6360
2256360
WHEEL DOZER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 2256360:
Information:
Starting Motor
Illustration 1 g00379835
Starting motor and starting motor solenoidNo load conditions at 25°C (77°F) Rpm with no load ... 4000 to 6000 rpm Maximum current ... 540 amperes Current draw with no load ... 130 amperes Voltage ... 11.5 volts Rated voltage ... 12 voltsPower rating 3003 engine ... 1.2 kilowatt 3013, 3014 and 3024 engines ... 2.0 kilowattsMinimum average cranking rpm ... 130Starting motor solenoid Pull-in current ... 54.5 amperes Hold-in current ... 10.5 amperes (1) Tighten the battery terminal nut to the following torque: ... 15 N m (11 lb ft) (2) Tighten the two mounting bolts to the following torque: ... 50 6 N m (37 4 lb ft) (3) Tighten the nut for the switch terminal to the following torque: ... 1.0 to 1.3 N m (9 to 12 lb in)Maximum resistance of the starter cable at 20°C (68°F) and at 12 volts ... 0.04 ohmsRefer to Testing and Adjusting, "Electrical System" for testing the starting motor.Start Relays
Illustration 2 g00381753
Schematic of the relays (4) When the ignition switch is in the OFF position or the RUN position, the relay switch is closed across the contact "30" and the contact "87a". (5) When the ignition switch is in the START position, the relay switch is closed across the contact "30" and the contact "87". Then, the starting motor is engaged.Maximum voltage drop in closed position ... 0.150 to 0.250 volts (6) Connector pins on the start relayResistance between contact "85" and contact "86" ... 7.2 0.7 ohms
Illustration 1 g00379835
Starting motor and starting motor solenoidNo load conditions at 25°C (77°F) Rpm with no load ... 4000 to 6000 rpm Maximum current ... 540 amperes Current draw with no load ... 130 amperes Voltage ... 11.5 volts Rated voltage ... 12 voltsPower rating 3003 engine ... 1.2 kilowatt 3013, 3014 and 3024 engines ... 2.0 kilowattsMinimum average cranking rpm ... 130Starting motor solenoid Pull-in current ... 54.5 amperes Hold-in current ... 10.5 amperes (1) Tighten the battery terminal nut to the following torque: ... 15 N m (11 lb ft) (2) Tighten the two mounting bolts to the following torque: ... 50 6 N m (37 4 lb ft) (3) Tighten the nut for the switch terminal to the following torque: ... 1.0 to 1.3 N m (9 to 12 lb in)Maximum resistance of the starter cable at 20°C (68°F) and at 12 volts ... 0.04 ohmsRefer to Testing and Adjusting, "Electrical System" for testing the starting motor.Start Relays
Illustration 2 g00381753
Schematic of the relays (4) When the ignition switch is in the OFF position or the RUN position, the relay switch is closed across the contact "30" and the contact "87a". (5) When the ignition switch is in the START position, the relay switch is closed across the contact "30" and the contact "87". Then, the starting motor is engaged.Maximum voltage drop in closed position ... 0.150 to 0.250 volts (6) Connector pins on the start relayResistance between contact "85" and contact "86" ... 7.2 0.7 ohms
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts radiator Caterpillar catalog:
2256338
RADIATOR GP
834H, 836H
834H, 836H
2584512
RADIATOR & FAN GP
G3520C
G3520C
2575709
RADIATOR & FAN GP
G3520C
G3520C
2381339
RADIATOR GP
990H
990H
2735036
RADIATOR GP
844H
844H
3811723
RADIATOR GP
C13, C15, CX31-C13I, CX31-C15I
C13, C15, CX31-C13I, CX31-C15I
3615539
RADIATOR GP
C13, C15, CX31-C13I, CX31-C15I
C13, C15, CX31-C13I, CX31-C15I
2391423
RADIATOR GP
3412C
3412C
2391422
RADIATOR GP
3412C
3412C
2391421
RADIATOR GP
3408C
3408C
2391420
RADIATOR GP
3406C
3406C