Compatible equipment models: 6H2951:
Information:
Illustration 1 g00940234
This diagnostic code is associated with the left station propel speed dial. The FMI 04 means that the ECM has determined that the voltage of the circuit for the sensor is below normal. The output frequency of the sensor is approximately 500 Hz. The duty cycle of the signal varies as the position sensor moves. The duty cycle varies from 2% to 98%.The possible causes of this diagnostic code are listed below:
The signal circuit for the sensor is shorted to ground.
The sensor has failed.
The ECM has failed. ECM failure is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1723 FMI 04 is active before performing this procedure. Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:When the diagnostic code is active, the following response occurs:
The machine ECM maintains the pre-fault value until a neutral reset occurs.
The sensor defaults to 50% after the neutral reset has taken place.
The fault lamp for the propulsion system is activated.
The action lamp is ON.Test Step 1. CHECK THE SENSOR
Turn the disconnect switch and the key start switch to the ON position.
Ensure that the diagnostic code is active.
Observe the status of the diagnostic code. Disconnect the sensor from the machine harness.Expected Result:The CID 1723 FMI 04 remains active. The FMI has not changed and the "04" is still active.Results:
OK - The diagnostic code remains active. The sensor is correct. Proceed to Test Step 2.
NOT OK - The diagnostic code is no longer active. The sensor has failed.Repair: Replace the sensor.STOPTest Step 2. CHECK THE WIRING HARNESS OF THE SENSOR FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness from the sensor.
Disconnect the machine harness connectors from the ECM.
At the machine harness connector for the ECM, measure the resistance from the signal contact J1-14 (wire A335-GY) of the machine harness to all possible sources of ground. Measure the resistance to all contacts of the machine harness connectors for the ECM.Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 4.
NOT OK - One or more resistance measurements are not correct. There is a short in the machine harness. Repair: The short is between signal contact J1-14 (wire A335-GY) and the circuit with the low resistance measurement. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK THE POTENTIOMETER
Access the potentiometer that is located in the left operator station.
Attach a 6V-7070 Digital Multimeter with 7X-1710 Multimeter Probes to the receptacle of the potentiometer without disconnecting the connectors. Connect the ground lead to pin "B" and connect the signal lead to connector pin "C".
Turn the disconnect switch and the engine start switch to the ON position, but do NOT start the engine.
Operate the
Caterpillar parts catalog:
Parts radiator Caterpillar catalog:
6L5427
RADIATOR ASSEM.
G3306
G3306
4370004
RADIATOR & MOUNTING GP
3.4B IOPU
3.4B IOPU
3783740
RADIATOR & MOUNTING GP
3.4B IOPU
3.4B IOPU
3746781
RADIATOR AS
C7.1
C7.1
3746780
RADIATOR
C7.1
C7.1
1931018
RADIATOR AS
M312, M315, M318, M320
M312, M315, M318, M320
1565651
RADIATOR AS
M312, M315, M318, M320
M312, M315, M318, M320
1226979
RADIATOR
315, 317
315, 317
1172845
RADIATOR
312
312
1118155
RADIATOR
312
312
3L0577
RADIATOR ASSEM.
D320A
D320A