AVSPARE.COM
parts catalog

RAW WATER PUMP GROUP 2N2407 - Caterpillar


2N2407 RAW WATER PUMP GROUP Caterpillar parts D353C
Rating:
12
Alternative (cross code) number:
CA2N2407
2N-2407
2N2407
Caterpillar 2N2407 RAW WATER PUMP GROUP
Weight: 60 pounds 27 kg.

Buy RAW WATER PUMP GROUP 2N2407 Caterpillar genuine, new aftermarket tractor parts with delivery
INDUSTRIAL ENGINE, MARINE ENGINE,

Compatible equipment models: 2N2407:

INDUSTRIAL ENGINE  D353C  
MARINE ENGINE  Caterpillar
Number on catalog scheme: 7
  For full view, you need register

Information:


Illustration 1 g00321237
Alarm Module (1) Amber indicators. (2) Red indicators. (3) Lamp test switch. (4) Alarm silence switch. (5) Horn.The alarm module (ALM) is an attachment. The ALM is located on the instrument panel. Red indicators (2) and amber indicators (1) are the visual indicators. The horn (5) is the audible indicator. The ALM is designed to be powered by only a 24 DCV battery system or a 32 DCV battery system. There are six versions of the basic module. The modules are either alarm modules or a remote annunciator. The term "remote annunciator" is used but the annunciator is the same basic alarm module. The versions are listed below.
NFPA 99 Standby alarm module.
A NFPA 99 remote annunciator which is used with a standby NFPA 99 alarm module.
NFPA 110 Standby alarm module which is used with NFPA 110 remote annunciator panel. See Systems Operation, "Alarm Module Control (NFPA 110)".
Prime power single engine alarm module .
Prime power multiple engine alarm module.
EMCP II remote annunciator.The only difference between these modules is in the graphics film on the front of the panel and the jumper wires on the rear of the panel. See the Testing And Adjusting, "DC Schematic". The NFPA 99 remote annunciator and the remote annunciator for the EMCP II have a lamp test switch. The alarm module (ALM) gives a warning of conditions that are becoming a problem. The warning occurs before conditions are severe enough to shut down the engine.If an alarm fault develops with the ECS in the COOLDOWN/STOP or AUTO positions, then the fault is indicated by the optional alarm module and/or the remote annunciator. Description of Change
Note: In the following description, the word "annunciator" may mean alarm module or remote annunciator module. The annunciator module receives data from switch inputs, internal circuitry, and a serial data link from the GSC. Switch Inputs
Four inputs are available as connections for the switch inputs. Switch inputs are activated when the inputs are connected to the battery negative terminal ("B-"). See Table 1.Internal Circuitry
Internal circuitry is used in order to determine if the DC battery supply voltage is too low. The setpoint is set at the factory at 24 DCV. Data Link
The annunciator module receives data from the generator set control (GSC) by a serial data link. The items that are included in this data stream of information are listed below.
Coolant temperature has exceeded the high temperature alarm setpoint

Caterpillar parts catalog:

Caterpillar parts catalog
D353E MARINE ENGINE 47B00409-UP
D353 ENGINE 46B01558-UP
D353 ENGINE 46B00001-00598
D353 ENGINE 46B00599-00808
D353 & G353 ENGINES 46B00809-01557
D353E MARINE ENGINE 47B00409-UP
D353 ENGINE 46B01558-UP
D353E MARINE ENGINE 47B00409-UP
D353 ENGINE 46B01558-UP
D353E MARINE ENGINE 47B00409-UP
D353 ENGINE 46B01558-UP


Parts raw Caterpillar catalog:

Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.