1898846 RECEPTACLE AS Caterpillar parts
950G, 950G II, 950H, 950K, 962G, 962G II, 962H, 962K, 966G, 966G II, 966H, 972G, 972G II, 972H, 980G, 980G II, 980H
Rating:
Alternative (cross code) number:
CA1898846
189-8846
1898846
CA1898846
189-8846
1898846
Weight: 0.02 pounds 0 kg.
WHEEL LOADER,
Compatible equipment models: 1898846:
Information:
225-8266 Ammeter Tool Gp
Illustration 1 g02231196
225-8266 Ammeter Tool Gp
The 225-8266 Ammeter Tool Gp is portable. This ammeter is a self-contained instrument that measures electrical currents without breaking the circuit and without disturbing the conductor insulation. The ammeter contains a digital display that is used to monitor current directly within a range between 1 A and 1200 A. In order to view current readings of less than 1 A use the multimeter display. In order to read the multimeter display connect a 6V-6014 Cable between the digital multimeter and the ammeter. The ammeter then sends the current measurement to the multimeter display.A lever opens the ammeter jaws over a conductor. The conductor diameter cannot be larger than 19 mm (0.75 inch).The spring loaded jaws close around the conductor for measuring the current. A trigger switch controls the ammeter. The trigger switch can be locked into the ON position or into the OFF position.After the trigger is turned to the OFF position, the reading appears in the digital display for 5 seconds. This meter accurately measures currents in areas with a limited access. For example, these areas include areas that are beyond the sight of the operator. For DC operation, the ammeter contains a zero control. Batteries inside the handle supply the power.Note: Refer to the user manual for more information about using the 225-8266 Ammeter Tool Gp. 237-5130 Digital Multimeter Gp or 146-4080 Digital Multimeter Gp
Illustration 2 g02231214
237-5130 Digital Multimeter Gp or 146-4080 Digital Multimeter Gp
The 237-5130 Digital Multimeter Gp or the 146-4080 Digital Multimeter Gp is a portable, hand-held service tool with a digital display. This multimeter is built with extra protection against damage in field applications. The multimeter is equipped with 7 functions and 29 ranges. The 237-5130 Digital Multimeter Gp or the 146-4080 Digital Multimeter Gp has an instant ohms indicator. This indicator permits checking continuity for a fast inspection of the circuits. The multimeter can also be used for troubleshooting capacitors that have small values.Note: Refer to the manual that is provided by the supplier for more information on the use of the 237-5130 Digital Multimeter Gp. Refer to Operation Manual, NEHS0678 for complete information for the use of the 146-4080 Digital Multimeter Gp.Charging System
To check for correct output of the alternator, see the Specifications module. Refer to Special Instruction, REHS0354, "Charging System Troubleshooting". If the part number for the alternator to be tested is not listed in the Special Instruction, refer to the appropriate Specifications manual for the information needed to test the alternator.Before the start of on-engine testing, the charging system and the battery must be checked according to the following steps.
The battery must be at least 75 percent (1.225 Sp Gr) of the full charge. The battery must be held tightly in place. The battery holder must not put too much stress on the battery.
Cables between the battery, the starter, and the engine ground must be the correct size. Wires and cables must be
Illustration 1 g02231196
225-8266 Ammeter Tool Gp
The 225-8266 Ammeter Tool Gp is portable. This ammeter is a self-contained instrument that measures electrical currents without breaking the circuit and without disturbing the conductor insulation. The ammeter contains a digital display that is used to monitor current directly within a range between 1 A and 1200 A. In order to view current readings of less than 1 A use the multimeter display. In order to read the multimeter display connect a 6V-6014 Cable between the digital multimeter and the ammeter. The ammeter then sends the current measurement to the multimeter display.A lever opens the ammeter jaws over a conductor. The conductor diameter cannot be larger than 19 mm (0.75 inch).The spring loaded jaws close around the conductor for measuring the current. A trigger switch controls the ammeter. The trigger switch can be locked into the ON position or into the OFF position.After the trigger is turned to the OFF position, the reading appears in the digital display for 5 seconds. This meter accurately measures currents in areas with a limited access. For example, these areas include areas that are beyond the sight of the operator. For DC operation, the ammeter contains a zero control. Batteries inside the handle supply the power.Note: Refer to the user manual for more information about using the 225-8266 Ammeter Tool Gp. 237-5130 Digital Multimeter Gp or 146-4080 Digital Multimeter Gp
Illustration 2 g02231214
237-5130 Digital Multimeter Gp or 146-4080 Digital Multimeter Gp
The 237-5130 Digital Multimeter Gp or the 146-4080 Digital Multimeter Gp is a portable, hand-held service tool with a digital display. This multimeter is built with extra protection against damage in field applications. The multimeter is equipped with 7 functions and 29 ranges. The 237-5130 Digital Multimeter Gp or the 146-4080 Digital Multimeter Gp has an instant ohms indicator. This indicator permits checking continuity for a fast inspection of the circuits. The multimeter can also be used for troubleshooting capacitors that have small values.Note: Refer to the manual that is provided by the supplier for more information on the use of the 237-5130 Digital Multimeter Gp. Refer to Operation Manual, NEHS0678 for complete information for the use of the 146-4080 Digital Multimeter Gp.Charging System
To check for correct output of the alternator, see the Specifications module. Refer to Special Instruction, REHS0354, "Charging System Troubleshooting". If the part number for the alternator to be tested is not listed in the Special Instruction, refer to the appropriate Specifications manual for the information needed to test the alternator.Before the start of on-engine testing, the charging system and the battery must be checked according to the following steps.
The battery must be at least 75 percent (1.225 Sp Gr) of the full charge. The battery must be held tightly in place. The battery holder must not put too much stress on the battery.
Cables between the battery, the starter, and the engine ground must be the correct size. Wires and cables must be
Cat SIS web machinery list:
Parts receptacle Caterpillar catalog:
8T8736
RECEPTACLE-CONNECTOR
2384C, 2470C, 2484C, 2570C, 2670C, 2864C, 3126B, 3176, 3176C, 3196, 3208, 3306, 3306B, 3406B, 3406C, 3406E, 3408B, 3412, 3412C, 3412E, 3456, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 416C, ...
2384C, 2470C, 2484C, 2570C, 2670C, 2864C, 3126B, 3176, 3176C, 3196, 3208, 3306, 3306B, 3406B, 3406C, 3406E, 3408B, 3412, 3412C, 3412E, 3456, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 416C, ...
8T8732
RECEPTACLE-CONNECTOR
120H, 120H ES, 135H, 246C, 256C, 262C, 262C2, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 3116, 311C, 311D LRR, 3126B, 312D, 312D L, 312D2, 312D2 L, 313D2 LGP, 314C, 314D CR,...
120H, 120H ES, 135H, 246C, 256C, 262C, 262C2, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 3116, 311C, 311D LRR, 3126B, 312D, 312D L, 312D2, 312D2 L, 313D2 LGP, 314C, 314D CR,...
1447929
RECEPTACLE AS
2290, 2390, 2391, 2491, 511, 521, 522, 532, 966G, 972G, AP-800D
2290, 2390, 2391, 2491, 511, 521, 522, 532, 966G, 972G, AP-800D
1896323
RECEPTACLE AS
966G II, 972G II
966G II, 972G II
3284418
RECEPTACLE AS
966H, 972H
966H, 972H
2466196
RECEPTACLE AS
966H, 972H
966H, 972H
1111562
RECEPTACLE AS
950H, 962H
950H, 962H
3561803
RECEPTACLE AS
950K, 962K
950K, 962K
2813122
RECEPTACLE AS-CONNECTOR
950K, 962K, 966K, 966M, 966M XE, 972K, 972M, 972M XE, 980K, 980M, 982M
950K, 962K, 966K, 966M, 966M XE, 972K, 972M, 972M XE, 980K, 980M, 982M
1018107
RECEPTACLE AS
793F CMD, 980F, 980G, 994H, R1300G, R1600G, R1600H, R1700G, R2900G, R3000H
793F CMD, 980F, 980G, 994H, R1300G, R1600G, R1600H, R1700G, R2900G, R3000H
3724874
RECEPTACLE AS
950H, 962H, 966H, 972H, 980H
950H, 962H, 966H, 972H, 980H
1309817
RECEPTACLE
938G II
938G II
6W8944
RECEPTACLE AS
824C, 826C, 936F, 950F, 950F II, 960F, 966F, 966F II, 970F, 980C, 980F, 980F II
824C, 826C, 936F, 950F, 950F II, 960F, 966F, 966F II, 970F, 980C, 980F, 980F II
9D8647
RECEPTACLE GROUP
637D, 994, 994D, R1700G, R2900G, R3000H
637D, 994, 994D, R1700G, R2900G, R3000H
3Y1890
RECEPTACLE
910, 920, 950, 966C
910, 920, 950, 966C
1V3344
RECEPTACLE
5130, 5230, 920, 930
5130, 5230, 920, 930
1907612
RECEPTACLE AS-CONNECTOR
785D, 793F, 950G II, 962G II, 966G II, 972G II, 980G II, RM-500
785D, 793F, 950G II, 962G II, 966G II, 972G II, 980G II, RM-500
9G4224
RECEPTACLE
120G, 834G, 834H, 836G, 836H, 854G, 988G, 988H, 992G
120G, 834G, 834H, 836G, 836H, 854G, 988G, 988H, 992G
7G8237
RECEPTACLE AS
10 FT, 10-20B, 10B, 8 FT, 8-16B, 844, 990, 990 II, AP-200B
10 FT, 10-20B, 10B, 8 FT, 8-16B, 844, 990, 990 II, AP-200B
2Q7301
RECEPTACLE AS
980G
980G
1603515
RECEPTACLE AS
990 II, R1300, R1600, R1600G, R1700G, R2900, R2900G
990 II, R1300, R1600, R1600G, R1700G, R2900, R2900G
1253556
RECEPTACLE AS
950G, 962G, 966G, 972G, 980G
950G, 962G, 966G, 972G, 980G