2128436 RECEPTACLE AS-CONNECTOR Caterpillar parts
793D, AD30, AD45, AD45B, AD55, AD55B, AD60, AE40 II, R1300G, R1300G II, R1600, R1600G, R1600H, R1700G, R2900, R2900G, R3000H
Rating:
Alternative (cross code) number:
CA2128436
212-8436
2128436
CA2128436
212-8436
2128436
Weight: 0.02 pounds 0 kg.
LOAD HAUL DUMP, UNDERGROUND ART TRUCK,
Compatible equipment models: 2128436:
Information:
The following background information is related to this procedure:The CAN data links are also known as J1939 data links. A data link is an industry standard for sending data between different devices in the same application.High-speed data is transferred via the data links. The data links cannot be accurately tested without complicated equipment. The data links require a resistance of 60 Ohms between the two wires to transmit the data correctly. This resistance is made up of two 120 Ohm resistors. The two resistors are known as "Terminating Resistors". The terminating resistors should be at opposite ends of a data link circuit. If this resistance is not present, then the data will be intermittent or unreadable.Note: The wiring for a J1939 data link is a shielded twisted-pair cable. If the wiring is damaged, the replacement type must be shielded twisted-pair cable.
Illustration 1 g06101687
Typical example of the schematic for the CAN A data link
Illustration 2 g06101696
Typical example of the schematic for the CAN B data link
Illustration 3 g06101703
Typical example of the schematic for the CAN C data link
Table 2
Troubleshooting Test Steps Values Results
1. Use the "System Communication Status to Check the Status of the Other Devices on the Suspect CAN Data Link"
A. In the electronic service tool, click the "Diagnostics" tab on the tool bar.
B. Select the "System Communication Status" option from the drop-down list.
Component Identified
Result: One or more of the devices on the suspect data link is not visible on the electronic service tool.
Repair: Thoroughly inspect the electrical connectors for the suspect devices
Refer to Troubleshooting, "Electrical Connectors - Inspect".
Check the power supply to the suspect devices.
If necessary, refer to Troubleshooting, "Electrical Power Supply - Test".
If the fault has been resolved, return the engine to service.
If the fault is still present, proceed to Test Step 2.
Result: All devices are visible on the electronic service tool.
Proceed to Test Step 2.
2. Check the Data Link Terminating Resistance
A. Disconnect the P1 and P2 connectors from the ECM.
B. Measure the resistance between P1:34 and P1:50.
C. Measure the resistance between the P2:21 and P2:29.
D. Measure the resistance between the P1:37 and P1:38.
Between 50 Ohms and 70 Ohms
Result: The resistance is less than 50 Ohms - there is a short circuit in the harness.
Repair: Repair the connectors or the harness and/or replace the connectors or the harness. Ensure that all the seals are correctly in place and ensure that the connectors are correctly connected.
Use the electronic service tool to clear all logged diagnostic codes and then verify that the repair eliminates the fault.
Result: The resistance is between 110 and 130 Ohms - one of the terminating resistors may have failed.
Repair: Locate the two terminating resistors and remove the two terminating resistors from the harness. Depending on the application, one or both of the terminating resistors may be located in other ECMs on the data link.
Measure the resistance of the two terminating resistors.
If one of the terminating resistors is incorrect, replace the faulty terminating resistor.
If the two terminating resistors are between 110 and 130 Ohms, proceed to Test Step
Illustration 1 g06101687
Typical example of the schematic for the CAN A data link
Illustration 2 g06101696
Typical example of the schematic for the CAN B data link
Illustration 3 g06101703
Typical example of the schematic for the CAN C data link
Table 2
Troubleshooting Test Steps Values Results
1. Use the "System Communication Status to Check the Status of the Other Devices on the Suspect CAN Data Link"
A. In the electronic service tool, click the "Diagnostics" tab on the tool bar.
B. Select the "System Communication Status" option from the drop-down list.
Component Identified
Result: One or more of the devices on the suspect data link is not visible on the electronic service tool.
Repair: Thoroughly inspect the electrical connectors for the suspect devices
Refer to Troubleshooting, "Electrical Connectors - Inspect".
Check the power supply to the suspect devices.
If necessary, refer to Troubleshooting, "Electrical Power Supply - Test".
If the fault has been resolved, return the engine to service.
If the fault is still present, proceed to Test Step 2.
Result: All devices are visible on the electronic service tool.
Proceed to Test Step 2.
2. Check the Data Link Terminating Resistance
A. Disconnect the P1 and P2 connectors from the ECM.
B. Measure the resistance between P1:34 and P1:50.
C. Measure the resistance between the P2:21 and P2:29.
D. Measure the resistance between the P1:37 and P1:38.
Between 50 Ohms and 70 Ohms
Result: The resistance is less than 50 Ohms - there is a short circuit in the harness.
Repair: Repair the connectors or the harness and/or replace the connectors or the harness. Ensure that all the seals are correctly in place and ensure that the connectors are correctly connected.
Use the electronic service tool to clear all logged diagnostic codes and then verify that the repair eliminates the fault.
Result: The resistance is between 110 and 130 Ohms - one of the terminating resistors may have failed.
Repair: Locate the two terminating resistors and remove the two terminating resistors from the harness. Depending on the application, one or both of the terminating resistors may be located in other ECMs on the data link.
Measure the resistance of the two terminating resistors.
If one of the terminating resistors is incorrect, replace the faulty terminating resistor.
If the two terminating resistors are between 110 and 130 Ohms, proceed to Test Step
Cat SIS web machinery list:
Parts receptacle Caterpillar catalog:
8T8732
RECEPTACLE-CONNECTOR
120H, 120H ES, 135H, 246C, 256C, 262C, 262C2, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 3116, 311C, 311D LRR, 3126B, 312D, 312D L, 312D2, 312D2 L, 313D2 LGP, 314C, 314D CR,...
120H, 120H ES, 135H, 246C, 256C, 262C, 262C2, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 3116, 311C, 311D LRR, 3126B, 312D, 312D L, 312D2, 312D2 L, 313D2 LGP, 314C, 314D CR,...
9X0352
RECEPTACLE AS
120M, 12M, 140M, 14M, 160M, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, 5130, 5130B, 5230, 5230B, 776C, 776D, 777, 777B, 777C, 777D, 784B, 784C, 785, 785B, 785C...
120M, 12M, 140M, 14M, 160M, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, 5130, 5130B, 5230, 5230B, 776C, 776D, 777, 777B, 777C, 777D, 784B, 784C, 785, 785B, 785C...
7X6195
RECEPTACLE-CONNECTOR
3508, 3508B, 3512, 3512B, 3512C, 3516B, 3516C, AD30, AD45B, AD55, AD55B, AD60, PR-1000, R1300G, R1300G II, R1600G, R1700G, R2900G, R3000H, RM-250C, RM-350B, RR-250, RR-250B, SM-350, SS-250
3508, 3508B, 3512, 3512B, 3512C, 3516B, 3516C, AD30, AD45B, AD55, AD55B, AD60, PR-1000, R1300G, R1300G II, R1600G, R1700G, R2900G, R3000H, RM-250C, RM-350B, RR-250, RR-250B, SM-350, SS-250
8S2633
RECEPTACLE ASSEM.
14G, 16G, 571G, 572G, 583K, 594H, 615, 657B, 657E, 777, 988B, 992C, AD45B, AD55, AD55B, AD60, D7G
14G, 16G, 571G, 572G, 583K, 594H, 615, 657B, 657E, 777, 988B, 992C, AD45B, AD55, AD55B, AD60, D7G
3898850
RECEPTACLE AS
R1600H
R1600H
2500525
RECEPTACLE
R2900G
R2900G
2124335
RECEPTACLE AS
AD30, AD45B, AD55, AD55B, AD60
AD30, AD45B, AD55, AD55B, AD60
3462341
RECEPTACLE AS
AD30, AD45B, AD55, AD55B, AD60
AD30, AD45B, AD55, AD55B, AD60
1433345
RECEPTACLE-CONNECTOR
AD30, AD45B, AD55, AD55B, AD60
AD30, AD45B, AD55, AD55B, AD60
3050673
RECEPTACLE AS
AD30, AD45B, AD55B, AD60
AD30, AD45B, AD55B, AD60
1868264
RECEPTACLE AS
AD30, AD45, AD45B, AD55, AD55B, AD60, AE40 II, R1300, R1300G, R1300G II, R1600, R1600G, R1600H, R1700G, R2900, R2900G, R3000H
AD30, AD45, AD45B, AD55, AD55B, AD60, AE40 II, R1300, R1300G, R1300G II, R1600, R1600G, R1600H, R1700G, R2900, R2900G, R3000H
2131434
RECEPTACLE AS
793D, AD30, AD45B, AD55, AD55B, AD60, R1300G, R1300G II, R1600G, R1600H, R1700G, R2900G, R3000H
793D, AD30, AD45B, AD55, AD55B, AD60, R1300G, R1300G II, R1600G, R1600H, R1700G, R2900G, R3000H
2124342
RECEPTACLE AS
AD30, AD45, AD45B, AD55, AD55B, AD60, AE40 II, R1300, R1300G, R1300G II, R1600, R1600G, R1700G, R2900, R2900G, R3000H
AD30, AD45, AD45B, AD55, AD55B, AD60, AE40 II, R1300, R1300G, R1300G II, R1600, R1600G, R1700G, R2900, R2900G, R3000H
2124331
RECEPTACLE AS
AD30, AD45, AD45B, AD55, AD55B, AD60, R1300G, R1300G II, R1600, R1600G, R1600H, R1700G, R2900G, R3000H
AD30, AD45, AD45B, AD55, AD55B, AD60, R1300G, R1300G II, R1600, R1600G, R1600H, R1700G, R2900G, R3000H
2458022
RECEPTACLE AS
725, 730, 735, 740
725, 730, 735, 740
3033835
RECEPTACLE AS
R1300G II
R1300G II
3050686
RECEPTACLE AS
R1300G, R1300G II, R2900G, R3000H
R1300G, R1300G II, R2900G, R3000H
2124333
RECEPTACLE AS
AD30, AD45B, AD55, AD55B, AD60, R1300G, R1300G II, R1600, R1600G, R1700 II, R1700G, R2900G, R3000H
AD30, AD45B, AD55, AD55B, AD60, R1300G, R1300G II, R1600, R1600G, R1700 II, R1700G, R2900G, R3000H
3050670
RECEPTACLE AS
AD55, R1300G, R1300G II
AD55, R1300G, R1300G II
2452181
RECEPTACLE
AD30, AD45B, AD55, AD55B, AD60, R1300G, R1300G II, R1700G, R2900G, R3000H
AD30, AD45B, AD55, AD55B, AD60, R1300G, R1300G II, R1700G, R2900G, R3000H
3083610
RECEPTACLE AS
AD30, AD45B, AD55, AD55B, AD60, R1300, R1300G, R1300G II, R1600, R1600G, R1600H, R1700 II, R1700G, R2900G, R3000H
AD30, AD45B, AD55, AD55B, AD60, R1300, R1300G, R1300G II, R1600, R1600G, R1600H, R1700 II, R1700G, R2900G, R3000H