Rating:
Alternative (cross code) number:
CA1262809
126-2809
1262809
CA1262809
126-2809
1262809
Weight: 7 pounds 3 kg.
GAS ENGINE, GENERATOR SET,
Compatible equipment models: 1262809:
Information:
Engine Starting Above 0°C (+32°F)
1. Move the propel control lever to NEUTRAL. 2. Push parking brake knob (1) down to apply the parking brake. 3. Move the accelerator handle to the low idle position. 4. Turn engine start switch key (2) to start the engine. Release engine start switch key (2) when the engine starts.
Do not crank the engine for more than 30 seconds. Allow the starter to cool for two minutes before cranking again.
For starting at temperatures below 0°C (+32°F), the use of additional optional starting aids is recommended. Extra battery capacity may be required. At temperatures below -23°C (-10°F), consult your Caterpillar dealer, or refer to the Operation & Maintenance Manual for Cold Weather Recommendations, Form SEBU5898, available from your Caterpillar dealer.Engine Starting with Jump Start Cables
Batteries give off flammable fumes that can explode resulting in personal injury.Prevent sparks near the batteries. They could cause vapors to explode. Do not allow jump start cable ends to contact each other or the machine. Do not smoke when checking battery electrolyte levels.Electrolyte is an acid and can cause personal injury if it contacts skin or eyes.Always wear eye protection when starting a machine with jump start cables. Improper jump start procedures can cause an explosion resulting in personal injury.Always connect the battery positive (+) to battery positive (+) and the battery negative (-) to battery negative (-).Jump start only with a battery source with the same voltage as the stalled machine.Turn off all lights and accessories on the stalled machine. Otherwise, they will operate when the jump source is connected.
When starting from another machine, make sure the machines do not touch. This could prevent damage to engine bearings and electrical circuits.Severely discharged maintenance free batteries will not fully recharge from the alternator alone after jump starting. These batteries must be charged to the proper voltage with a battery charger. Many batteries, thought to be unusable, are still rechargeable.This machine has a 12 volt starting system. Use only equal voltage for jump starting. Use of a higher voltage will damage the electrical system. Refer to Special Instruction, Battery Test Procedure, SEHS7633, available from your Caterpillar dealer, for complete testing and charging information.
Use of Jump Start Cables
When auxiliary start receptacles are not available, use the following procedure.1. Make initial determination as to failure of machine to crank. Refer to Special Instruction SEHS7768 on use of 6V-2150 Starting/Charging Analyzer Group. Procedure applies even if machine does not have diagnostic connector.2. Place the propel control lever in NEUTRAL on the stalled machine. Apply the parking brake.3. On stalled machine, turn the engine start switch key to OFF. Turn off all accessories.4. On stalled machine, turn on (close) the disconnect switch (if equipped).5. Move electrical source (machine) near enough to stalled machine for the jump start cables to reach. But, do not allow machines to touch.6. Stop the engine on the electrical source machine. Or, if using an auxiliary power source, turn off the charging system.7. Make sure battery caps are
1. Move the propel control lever to NEUTRAL. 2. Push parking brake knob (1) down to apply the parking brake. 3. Move the accelerator handle to the low idle position. 4. Turn engine start switch key (2) to start the engine. Release engine start switch key (2) when the engine starts.
Do not crank the engine for more than 30 seconds. Allow the starter to cool for two minutes before cranking again.
For starting at temperatures below 0°C (+32°F), the use of additional optional starting aids is recommended. Extra battery capacity may be required. At temperatures below -23°C (-10°F), consult your Caterpillar dealer, or refer to the Operation & Maintenance Manual for Cold Weather Recommendations, Form SEBU5898, available from your Caterpillar dealer.Engine Starting with Jump Start Cables
Batteries give off flammable fumes that can explode resulting in personal injury.Prevent sparks near the batteries. They could cause vapors to explode. Do not allow jump start cable ends to contact each other or the machine. Do not smoke when checking battery electrolyte levels.Electrolyte is an acid and can cause personal injury if it contacts skin or eyes.Always wear eye protection when starting a machine with jump start cables. Improper jump start procedures can cause an explosion resulting in personal injury.Always connect the battery positive (+) to battery positive (+) and the battery negative (-) to battery negative (-).Jump start only with a battery source with the same voltage as the stalled machine.Turn off all lights and accessories on the stalled machine. Otherwise, they will operate when the jump source is connected.
When starting from another machine, make sure the machines do not touch. This could prevent damage to engine bearings and electrical circuits.Severely discharged maintenance free batteries will not fully recharge from the alternator alone after jump starting. These batteries must be charged to the proper voltage with a battery charger. Many batteries, thought to be unusable, are still rechargeable.This machine has a 12 volt starting system. Use only equal voltage for jump starting. Use of a higher voltage will damage the electrical system. Refer to Special Instruction, Battery Test Procedure, SEHS7633, available from your Caterpillar dealer, for complete testing and charging information.
Use of Jump Start Cables
When auxiliary start receptacles are not available, use the following procedure.1. Make initial determination as to failure of machine to crank. Refer to Special Instruction SEHS7768 on use of 6V-2150 Starting/Charging Analyzer Group. Procedure applies even if machine does not have diagnostic connector.2. Place the propel control lever in NEUTRAL on the stalled machine. Apply the parking brake.3. On stalled machine, turn the engine start switch key to OFF. Turn off all accessories.4. On stalled machine, turn on (close) the disconnect switch (if equipped).5. Move electrical source (machine) near enough to stalled machine for the jump start cables to reach. But, do not allow machines to touch.6. Stop the engine on the electrical source machine. Or, if using an auxiliary power source, turn off the charging system.7. Make sure battery caps are
Caterpillar SIS machinery equipment:
Caterpillar SIS
G3412 Engine 6ZM00001-UP »
126-2809
REGULATOR GP-GAS PRESSURE
G3508 Engine 2TJ00001-UP »
126-2809
REGULATOR GP-GAS PRESSURE
G3508 Generator Set CPS00001-UP »
126-2809
REGULATOR GP-GAS PRESSURE
G3412 Generator Set KAP00001-UP »
126-2809
REGULATOR GP-GAS PRESSURE
G3412 Generator Set R7A00001-UP »
126-2809
REGULATOR GP-GAS PRESSURE
Caterpillar parts catalog:
Parts regulator Caterpillar catalog:
1553832
REGULATOR AS-VOLTAGE
3126B, 3208, 3306, 3306B, 3406B, 3406C, 3406E, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, 3612, C-12, C15, C18, G3306, G3306B, G3406, G3408, G3412, G3508, G3512, G3516, G3516B, G3516C, ...
3126B, 3208, 3306, 3306B, 3406B, 3406C, 3406E, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, 3612, C-12, C15, C18, G3306, G3306B, G3406, G3408, G3412, G3508, G3512, G3516, G3516B, G3516C, ...
3147755
REGULATOR AS-VOLTAGE
3208, 3306, 3306B, 3406B, 3406C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3612, C15, C15 I6, C175-16, C175-20, C18, C18 I6, C27, C32, C7.1, C9, G3306, G3306B, G3406, G34...
3208, 3306, 3306B, 3406B, 3406C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3612, C15, C15 I6, C175-16, C175-20, C18, C18 I6, C27, C32, C7.1, C9, G3306, G3306B, G3406, G34...
2028634
REGULATOR AS-VOLTAGE
3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, C15, C18, C32, C9, G3306, G3406, G3408, G3408B, G3412, G3508, G3512, ...
3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, C15, C18, C32, C9, G3306, G3406, G3408, G3408B, G3412, G3508, G3512, ...
2477133
REGULATOR-TEMPERATURE
140H, 143H, 14H, 160H, 163H, 1673C, 16H, 3126B, 3176, 3176B, 3176C, 3196, 3306, 3306C, 330D, 330D FM, 330D L, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 3406B, 3406C, 3406E, 3408, 340D L, 340D2 L...
140H, 143H, 14H, 160H, 163H, 1673C, 16H, 3126B, 3176, 3176B, 3176C, 3196, 3306, 3306C, 330D, 330D FM, 330D L, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 3406B, 3406C, 3406E, 3408, 340D L, 340D2 L...
3T6354
REGULATOR AS-VOLTAGE
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 16G, 16H, 16...
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 16G, 16H, 16...
7T2798
REGULATOR AS-VOLTAGE
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 235, 245, 3114, 3116, ...
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 235, 245, 3114, 3116, ...
9G7567
REGULATOR AS-VOLTAGE
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 235, 245, 3114, 3116, ...
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 235, 245, 3114, 3116, ...
2485513
REGULATOR-TEMPERATURE
12H, 140M, 140M 2, 14M, 160M, 160M 2, 16G, 16H NA, 16M, 2290, 2390, 2391, 2491, 24H, 24M, 2590, 3176, 330C, 330C FM, 330C L, 330C MH, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 34...
12H, 140M, 140M 2, 14M, 160M, 160M 2, 16G, 16H NA, 16M, 2290, 2390, 2391, 2491, 24H, 24M, 2590, 3176, 330C, 330C FM, 330C L, 330C MH, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 34...
5L5006
REGULATOR-LEVEL
3412, 3508, 3508B, 3508C, 3512, 3512B, 3516, 3516B, D379B, D398B, D399, G3508, G3512, G3516, G3516B, G3520B, G379, G399, PM3412, PM3508, PM3512, PM3516
3412, 3508, 3508B, 3508C, 3512, 3512B, 3516, 3516B, D379B, D398B, D399, G3508, G3512, G3516, G3516B, G3520B, G379, G399, PM3412, PM3508, PM3512, PM3516
2136133
REGULATOR AS
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C27, C32, G3508, G3508B, G3512, G3512E, G3516, G3516B, G3516C, G3516E, G3516H, G3520B, G3520C, G3520E, PM3412, PM3508, PM3512, PM3516, PMG35...
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C27, C32, G3508, G3508B, G3512, G3512E, G3516, G3516B, G3516C, G3516E, G3516H, G3520B, G3520C, G3520E, PM3412, PM3508, PM3512, PM3516, PMG35...
3073274
REGULATOR
3508B, 3512, 3512B, 3512C, 3516, 3516B, C27, C32, G3412, PM3516, PP3516
3508B, 3512, 3512B, 3512C, 3516, 3516B, C27, C32, G3412, PM3516, PP3516
1516017
REGULATOR AS-WATER TEMPERATURE
G3508, G3512, G3516, G3516B
G3508, G3512, G3516, G3516B
1553823
REGULATOR GP-VOLTAGE
3508, 3512, 3516, 3516B, G3516, SR4
3508, 3512, 3516, 3516B, G3516, SR4
1137686
REGULATOR AS-VOLTAGE
3508, 3512, G3512, G3516, SR4
3508, 3512, G3512, G3516, SR4
1979069
REGULATOR GP-TEMPERATURE
3508, 3508B, PM3508
3508, 3508B, PM3508
1546117
REGULATOR GP-VOLTAGE
3508, 3508B, 3512, 3512B, 3516, 3516B, SR4B
3508, 3508B, 3512, 3512B, 3516, 3516B, SR4B