1303460 REGULATOR GP-VOLTAGE Caterpillar parts
3306B, 3406C, C15, C18, G3306B  
 
 
Rating:
 Alternative (cross code) number:
CA1303460
130-3460
1303460
 
CA1303460
130-3460
1303460
 
GEN SET ENGINE, PETROLEUM GEN SET,
Compatible equipment models: 1303460:
Information:
 Vibratory Electrical System
Illustration 1 g01966693
Electrical Schematic for Vibratory System
(1) B+ from main power supply
(2) Vibratory fuse
(3) Gauge fuse
(4) ECM fuse
(5) "CAN" port
(6) "CAN" resistor
(7) Electronic control module
(8) Drum selector switch
(9) From light master switch
(10) Propulsion lever
(11) Propulsion sensor
(12) Vibratory indicator
(13) Reverse solenoid
(14) Forward solenoid
(15) Front motor selector solenoid
(16) Vibratory mode control switch
(17) Vibratory tachometer
(18) Front motor speed sensor
(19) Rear motor speed sensor
(20) Rear motor selector solenoid
(21) Amplitutde selector switch
(22) 2 Amplitude machines must connect C18 to C20 and C19 to C21. 5 Amplitude machines must connect C18 to C21 and C19 to C20. When the main power relay is energized, power is available at the ECM fuse, the vibratory fuse, and the gauge fuse through 112-PU(Purple) wires. Power transfers from the ECM fuse to the following places:
Contact "1" of the propel sensor
Contact "28" of connector "C4"
Terminal "2" and terminal "47" through terminal "50" of the ECM.The 103-YL(Yellow) wires distributes power from the vibratory fuse to contact "2" of the drum selector switch, contact "2" of the vibratory mode control switch, and contact "5" of the amplitude selector switch (if equipped). Power transfers from the gauge fuse to contact "I" of the vibratory tachometer.After the ECM receives power, it begins to monitor the circuit at terminal "29". The vibratory master switch on the propel lever provides the input signal to this terminal. When the vibratory master switch is depressed, the circuit at terminal "29" of the ECM is complete. This prompts the ECM to initiate the vibratory control logic.Since the vibratory master switch is a momentary type switch, the circuit at terminal "29" of the ECM is only complete while the switch is held. When the switch is released, the circuit at terminal "29" returns to its natural state. The ECM monitors the number of times that the vibratory master switch is closed to determine if the vibratory system is ON or OFF. The first time the vibratory master switch is closed (and on all subsequent odd numbered times), the ECM enables the vibratory system. The second time the switch is depressed (and on all subsequent even numbered times), the ECM disables the vibratory system.When the ECM determines that the vibratory system is ON, the ECM monitors the circuit at terminal "16" to determine the position of the vibratory mode control switch and the circuit at terminal "24" to determine the position of the propel lever. When the vibratory mode control switch is in the MANUAL position, contact "2" and contact "3" of the switch are open, and the circuit at terminal "16" of the ECM is open. Terminal "24" of the ECM monitors the input signal from the propel lever sensor. The sensor generates a pulse width modulated signal with a duty cycle of between 9 and 91 percent. The duty cycle (time on versus time off) of the signal depends on the position of the propel lever. The lowest duty cycle corresponds to the FULL REVERSE position, and the highest duty cycle corresponds to the FULL FORWARD
 Illustration 1 g01966693
Electrical Schematic for Vibratory System
(1) B+ from main power supply
(2) Vibratory fuse
(3) Gauge fuse
(4) ECM fuse
(5) "CAN" port
(6) "CAN" resistor
(7) Electronic control module
(8) Drum selector switch
(9) From light master switch
(10) Propulsion lever
(11) Propulsion sensor
(12) Vibratory indicator
(13) Reverse solenoid
(14) Forward solenoid
(15) Front motor selector solenoid
(16) Vibratory mode control switch
(17) Vibratory tachometer
(18) Front motor speed sensor
(19) Rear motor speed sensor
(20) Rear motor selector solenoid
(21) Amplitutde selector switch
(22) 2 Amplitude machines must connect C18 to C20 and C19 to C21. 5 Amplitude machines must connect C18 to C21 and C19 to C20. When the main power relay is energized, power is available at the ECM fuse, the vibratory fuse, and the gauge fuse through 112-PU(Purple) wires. Power transfers from the ECM fuse to the following places:
Contact "1" of the propel sensor
Contact "28" of connector "C4"
Terminal "2" and terminal "47" through terminal "50" of the ECM.The 103-YL(Yellow) wires distributes power from the vibratory fuse to contact "2" of the drum selector switch, contact "2" of the vibratory mode control switch, and contact "5" of the amplitude selector switch (if equipped). Power transfers from the gauge fuse to contact "I" of the vibratory tachometer.After the ECM receives power, it begins to monitor the circuit at terminal "29". The vibratory master switch on the propel lever provides the input signal to this terminal. When the vibratory master switch is depressed, the circuit at terminal "29" of the ECM is complete. This prompts the ECM to initiate the vibratory control logic.Since the vibratory master switch is a momentary type switch, the circuit at terminal "29" of the ECM is only complete while the switch is held. When the switch is released, the circuit at terminal "29" returns to its natural state. The ECM monitors the number of times that the vibratory master switch is closed to determine if the vibratory system is ON or OFF. The first time the vibratory master switch is closed (and on all subsequent odd numbered times), the ECM enables the vibratory system. The second time the switch is depressed (and on all subsequent even numbered times), the ECM disables the vibratory system.When the ECM determines that the vibratory system is ON, the ECM monitors the circuit at terminal "16" to determine the position of the vibratory mode control switch and the circuit at terminal "24" to determine the position of the propel lever. When the vibratory mode control switch is in the MANUAL position, contact "2" and contact "3" of the switch are open, and the circuit at terminal "16" of the ECM is open. Terminal "24" of the ECM monitors the input signal from the propel lever sensor. The sensor generates a pulse width modulated signal with a duty cycle of between 9 and 91 percent. The duty cycle (time on versus time off) of the signal depends on the position of the propel lever. The lowest duty cycle corresponds to the FULL REVERSE position, and the highest duty cycle corresponds to the FULL FORWARD
Caterpillar SIS machinery equipment:
Caterpillar SIS
 
 3306B Generator Set 9NR00001-UP »
 130-3460
REGULATOR GP-VOLTAGE 
 
 3306B Generator Set 9NR00001-UP »
 130-3460
REGULATOR GP-VOLTAGE 
 
 3306B Generator Set 9NR00001-UP »
 130-3460
REGULATOR GP-VOLTAGE 
 
 3406C Generator Set 1LS00001-UP »
 130-3460
REGULATOR GP-VOLTAGE 
 
 3406C Generator Set 1LS00001-UP »
 130-3460
REGULATOR GP-VOLTAGE 
 
 3406C Generator Set 1LS00001-UP »
 130-3460
REGULATOR GP-VOLTAGE 
 
 3406C Generator Set 4ZR00001-UP »
 130-3460
REGULATOR GP-VOLTAGE 
 
 3406C Generator Set 4ZR00001-UP »
 130-3460
REGULATOR GP-VOLTAGE 
 
 3406C Generator Set 4ZR00001-UP »
 130-3460
REGULATOR GP-VOLTAGE 
 
 3406C Generator Set KPS00001-UP »
 130-3460
REGULATOR GP-VOLTAGE 
 
 3406C Generator Set KPS00001-UP »
 130-3460
REGULATOR GP-VOLTAGE 
 
 3306B Generator Set B8D00001-UP »
 130-3460
REGULATOR GP-VOLTAGE 
 
 C15 Standby Generator Set (60Hz) C5E00001-UP »
 130-3460
REGULATOR GP-VOLTAGE 
 
 C15 Petroleum Gen Set Package 11500001-UP POWERED BY C15 Engine »
 130-3460
REGULATOR GP-VOLTAGE 
 
 C15 Petroleum Generator Set PEC00001-UP »
 130-3460
REGULATOR GP-VOLTAGE 
 
 C18 Generator Set 18800001-UP »
 130-3460
REGULATOR GP-VOLTAGE 
 
 G3306B Petroleum Generator Set NR400001-UP »
 130-3460
REGULATOR GP-VOLTAGE 
 
 XQG135 Power Module G3306B Engine AL400001-UP »
 130-3460
REGULATOR GP-VOLTAGE 
 Parts regulator Caterpillar catalog:
 2028634
REGULATOR AS-VOLTAGE
 
3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, C15, C18, C32, C9, G3306, G3406, G3408, G3408B, G3412, G3508, G3512, ...
 
3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, C15, C18, C32, C9, G3306, G3406, G3408, G3408B, G3412, G3508, G3512, ...
 3E5451
REGULATOR AS
 
1673C, 3114, 3116, 3126, 3126B, 3176, 3176B, 3176C, 3196, 3208, 3304, 3306, 3306B, 3306C, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3456, 35, 45, 55, 573, 65C, 65E, 75, 75C, 7...
 
1673C, 3114, 3116, 3126, 3126B, 3176, 3176B, 3176C, 3196, 3208, 3304, 3306, 3306B, 3306C, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3456, 35, 45, 55, 573, 65C, 65E, 75, 75C, 7...
 1118010
REGULATOR-WATER TEMPERATURE
 
120G, 12G, 12H, 12H ES, 12H NA, 130G, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 235B, 330, 330 FM L, 330 L, 3304, 3304B, 3306, 3306B, 3306C, 330B, 330B L,...
 
120G, 12G, 12H, 12H ES, 12H NA, 130G, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 235B, 330, 330 FM L, 330 L, 3304, 3304B, 3306, 3306B, 3306C, 330B, 330B L,...
 1167577
REGULATOR-WATER TEMPERATURE
 
12H, 12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14H NA, 160H, 160H ES, 160H NA, 163H NA, 3306, G3304, G3304B, G3306, G3306B
 
12H, 12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14H NA, 160H, 160H ES, 160H NA, 163H NA, 3306, G3304, G3304B, G3306, G3306B
 2477133
REGULATOR-TEMPERATURE
 
140H, 143H, 14H, 160H, 163H, 1673C, 16H, 3126B, 3176, 3176B, 3176C, 3196, 3306, 3306C, 330D, 330D FM, 330D L, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 3406B, 3406C, 3406E, 3408, 340D L, 340D2 L...
 
140H, 143H, 14H, 160H, 163H, 1673C, 16H, 3126B, 3176, 3176B, 3176C, 3196, 3306, 3306C, 330D, 330D FM, 330D L, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 3406B, 3406C, 3406E, 3408, 340D L, 340D2 L...
 3T6354
REGULATOR AS-VOLTAGE
 
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 16G, 16H, 16...
 
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 16G, 16H, 16...
 1348278
REGULATOR GP-VOLTAGE
 
3114, 3116, 3126, 3126B, 3176B, 3176C, 3196, 3208, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3412D, 3412E, C-12, C15, C18, G3304, G3304B, G3306, G3306B
 
3114, 3116, 3126, 3126B, 3176B, 3176C, 3196, 3208, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3412D, 3412E, C-12, C15, C18, G3304, G3304B, G3306, G3306B
 7T2798
REGULATOR AS-VOLTAGE
 
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 235, 245, 3114, 3116, ...
 
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 235, 245, 3114, 3116, ...
 9G7567
REGULATOR AS-VOLTAGE
 
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 235, 245, 3114, 3116, ...
  
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 235, 245, 3114, 3116, ...
 1256692
REGULATOR GP-GAS PRESSURE
 
G3408, G3408C, G3412C
 
G3408, G3408C, G3412C
 1979069
REGULATOR GP-TEMPERATURE
 
3508, 3508B, PM3508
 
 
 
3508, 3508B, PM3508
 1546117
REGULATOR GP-VOLTAGE
 
3508, 3508B, 3512, 3512B, 3516, 3516B, SR4B
 
  
3508, 3508B, 3512, 3512B, 3516, 3516B, SR4B
 1390397
REGULATOR GP-VOLTAGE
 
3606, 3608, 3612, 3616, G3612, G3616, SR4
 
3606, 3608, 3612, 3616, G3612, G3616, SR4
 1390369
REGULATOR GP-VOLTAGE
 
3606, 3608, 3612, 3616, G3612, G3616, SR4
 
3606, 3608, 3612, 3616, G3612, G3616, SR4
 1390339
REGULATOR GP-VOLTAGE
 
3606, 3608, 3612, 3616, G3612, G3616, SR4
 
3606, 3608, 3612, 3616, G3612, G3616, SR4
 1422043
REGULATOR GP-TEMPERATURE
 
C-10, C-12
 
C-10, C-12
 1303652
REGULATOR GP-VOLTAGE
 
3306B, 3406C, C15, C18, G3306B
 
3306B, 3406C, C15, C18, G3306B
 1303651
REGULATOR GP-VOLTAGE
 
3306B, 3406C, C15, C18, G3306B
 
3306B, 3406C, C15, C18, G3306B