1761252 REGULATOR AS Caterpillar parts
3126B, 570B, 580B, 938G II, 950G II, 962G II, D6R II, IT38G II, IT62G II, MTC735
Rating:
Alternative (cross code) number:
CA1761252
176-1252
1761252
CA1761252
176-1252
1761252
Weight: 0.39 pounds 0 kg.
CHALLENGER, WHEEL LOADER,
This part in 2 request:
Show.
This information for suppliers only!
2023-11-23
2020-09-29
Compatible equipment models: 1761252:
Information:
Generator Loading
When a generator is installed or reconnected, be sure the total current in one phase does not exceed the nameplate rating. Each phase should carry the same load, allowing the engine to work at its rated capacity. An electrical unbalance can result in an electrical overload and overheating if one phase exceeds the nameplate amperage. Any unbalanced load that's required should be placed on phase 2, since current sensing for voltage regulator is on that phase.Power Factor
Power factor may be thought of as the efficiency of the load - the ratio of apparent power to total power. Power factor is expressed as a decimal and denotes that portion of current supplied to a system doing useful work. The portion of current not doing useful work is absorbed in maintaining the magnetic field in motors. This current, although it is called the reactive load, does not require engine horsepower to maintain it.In most applications electric motors and transformers determine the power factor of the system. Induction motors usually have a .8 power factor. Incadescent lighting is a resistive load to about 1.0 power factor, or unity.The power factor of a system may be determined by a power factor meter or by calculations. Determine the power requirement in KW by multiplying the power factor by the KVA supplied to the system. As the power factor goes up the total current supplied to a constant power demand will go down. A 100 KW load at a .8 power factor will draw more current than a 100 KW load at .9 power factor. A higher power factor increases the possibility of overloading the engine. A lower power factor increases the possibility of overloading the generator.Low Idle Adjustment
Electric sets require higher low idle setting than do industrial engines. Low idle must not be below 2/3 the full load speed of 60 Hz units (4/5 full load speed of 50 Hz units).
Disconnect the exciter circuit by removing fuses F1 and F2 (on SRCR) or Fuse F1 (on SR 4) before operating the engine below the low idle rating. Failure to do this will result in generator damage.
On electric sets with Woodward governors, there is no low idle stop. On electric sets with mechanical governors and natural gas electric sets, the low idle is set at the factory, and should only be adjusted by your Caterpillar dealer if adjustment is required.
When a generator is installed or reconnected, be sure the total current in one phase does not exceed the nameplate rating. Each phase should carry the same load, allowing the engine to work at its rated capacity. An electrical unbalance can result in an electrical overload and overheating if one phase exceeds the nameplate amperage. Any unbalanced load that's required should be placed on phase 2, since current sensing for voltage regulator is on that phase.Power Factor
Power factor may be thought of as the efficiency of the load - the ratio of apparent power to total power. Power factor is expressed as a decimal and denotes that portion of current supplied to a system doing useful work. The portion of current not doing useful work is absorbed in maintaining the magnetic field in motors. This current, although it is called the reactive load, does not require engine horsepower to maintain it.In most applications electric motors and transformers determine the power factor of the system. Induction motors usually have a .8 power factor. Incadescent lighting is a resistive load to about 1.0 power factor, or unity.The power factor of a system may be determined by a power factor meter or by calculations. Determine the power requirement in KW by multiplying the power factor by the KVA supplied to the system. As the power factor goes up the total current supplied to a constant power demand will go down. A 100 KW load at a .8 power factor will draw more current than a 100 KW load at .9 power factor. A higher power factor increases the possibility of overloading the engine. A lower power factor increases the possibility of overloading the generator.Low Idle Adjustment
Electric sets require higher low idle setting than do industrial engines. Low idle must not be below 2/3 the full load speed of 60 Hz units (4/5 full load speed of 50 Hz units).
Disconnect the exciter circuit by removing fuses F1 and F2 (on SRCR) or Fuse F1 (on SR 4) before operating the engine below the low idle rating. Failure to do this will result in generator damage.
On electric sets with Woodward governors, there is no low idle stop. On electric sets with mechanical governors and natural gas electric sets, the low idle is set at the factory, and should only be adjusted by your Caterpillar dealer if adjustment is required.
Caterpillar parts catalog:
Parts regulator Caterpillar catalog:
1265869
REGULATOR-WATER
120H, 120H ES, 120H NA, 12H, 135H, 135H NA, 140M, 140M 2, 160M, 160M 2, 3114, 3116, 3126, 3126B, 320 L, 320B, 322B, 322B L, 322B LN, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325 L, 3...
120H, 120H ES, 120H NA, 12H, 135H, 135H NA, 140M, 140M 2, 160M, 160M 2, 3114, 3116, 3126, 3126B, 320 L, 320B, 322B, 322B L, 322B LN, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325 L, 3...
3E5451
REGULATOR AS
1673C, 3114, 3116, 3126, 3126B, 3176, 3176B, 3176C, 3196, 3208, 3304, 3306, 3306B, 3306C, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3456, 35, 45, 55, 573, 65C, 65E, 75, 75C, 7...
1673C, 3114, 3116, 3126, 3126B, 3176, 3176B, 3176C, 3196, 3208, 3304, 3306, 3306B, 3306C, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3456, 35, 45, 55, 573, 65C, 65E, 75, 75C, 7...
2477133
REGULATOR-TEMPERATURE
140H, 143H, 14H, 160H, 163H, 1673C, 16H, 3126B, 3176, 3176B, 3176C, 3196, 3306, 3306C, 330D, 330D FM, 330D L, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 3406B, 3406C, 3406E, 3408, 340D L, 340D2 L...
140H, 143H, 14H, 160H, 163H, 1673C, 16H, 3126B, 3176, 3176B, 3176C, 3196, 3306, 3306C, 330D, 330D FM, 330D L, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 3406B, 3406C, 3406E, 3408, 340D L, 340D2 L...
3T6354
REGULATOR AS-VOLTAGE
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 16G, 16H, 16...
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 16G, 16H, 16...
1348278
REGULATOR GP-VOLTAGE
3114, 3116, 3126, 3126B, 3176B, 3176C, 3196, 3208, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3412D, 3412E, C-12, C15, C18, G3304, G3304B, G3306, G3306B
3114, 3116, 3126, 3126B, 3176B, 3176C, 3196, 3208, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3412D, 3412E, C-12, C15, C18, G3304, G3304B, G3306, G3306B
1052063
REGULATOR AS-ALTERNATOR
214B, 3114, 3116, 3126, 3126B, 3208, 320B, 322B L, 322B LN, 322C, 325B L, 3306, 3306B, 916, 924F, 924G, 924GZ, 928G, 938F, 938G, 938G II, AP-1000B, AP-1055B, AP-800C, AP-900B, BG-225B, BG-2455C, BG-24...
214B, 3114, 3116, 3126, 3126B, 3208, 320B, 322B L, 322B LN, 322C, 325B L, 3306, 3306B, 916, 924F, 924G, 924GZ, 928G, 938F, 938G, 938G II, AP-1000B, AP-1055B, AP-800C, AP-900B, BG-225B, BG-2455C, BG-24...
1852648
REGULATOR AS-VOLTAGE
1090, 1190, 1190T, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 1290T, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 135H, 135H NA, 1390, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 143H, 14H, 14H NA, 14M,...
1090, 1190, 1190T, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 1290T, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 135H, 135H NA, 1390, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 143H, 14H, 14H NA, 14M,...
2485513
REGULATOR-TEMPERATURE
12H, 140M, 140M 2, 14M, 160M, 160M 2, 16G, 16H NA, 16M, 2290, 2390, 2391, 2491, 24H, 24M, 2590, 3176, 330C, 330C FM, 330C L, 330C MH, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 34...
12H, 140M, 140M 2, 14M, 160M, 160M 2, 16G, 16H NA, 16M, 2290, 2390, 2391, 2491, 24H, 24M, 2590, 3176, 330C, 330C FM, 330C L, 330C MH, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 34...
3696662
REGULATOR AS
120H, 120K, 120K 2, 12H, 12K, 12M, 135H, 140G, 140K, 140K 2, 140M, 140M 2, 160K, 160M, 160M 2, 2290, 2390, 2391, 2491, 2590, 3126, 3126B, 3126E, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L, 324D ...
120H, 120K, 120K 2, 12H, 12K, 12M, 135H, 140G, 140K, 140K 2, 140M, 140M 2, 160K, 160M, 160M 2, 2290, 2390, 2391, 2491, 2590, 3126, 3126B, 3126E, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L, 324D ...
2298870
REGULATOR AS
120H, 3126B, 322C, 570B, 580B, 938G II, 950H, 953C, 963C, C-9, C9, D6N, D6R II
120H, 3126B, 322C, 570B, 580B, 938G II, 950H, 953C, 963C, C-9, C9, D6N, D6R II
2948620
REGULATOR AS
325D L, 329D L, 950H, C9, CX31-C9I, D6N, D6R, D6R II, D6R III, D7R XR
325D L, 329D L, 950H, C9, CX31-C9I, D6N, D6R, D6R II, D6R III, D7R XR
2099234
REGULATOR-PRESSURE
12H, 12M, 140G, 140M, 160M, 2290, 2390, 2391, 2491, 2590, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325C, 325C FM, 325D, 325D FM, 325D FM LL, 325D L, 325D MH, 328D LCR, 329D, 329D L, ...
12H, 12M, 140G, 140M, 160M, 2290, 2390, 2391, 2491, 2590, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325C, 325C FM, 325D, 325D FM, 325D FM LL, 325D L, 325D MH, 328D LCR, 329D, 329D L, ...
2485513
REGULATOR-TEMPERATURE
12H, 140M, 140M 2, 14M, 160M, 160M 2, 16G, 16H NA, 16M, 2290, 2390, 2391, 2491, 24H, 24M, 2590, 3176, 330C, 330C FM, 330C L, 330C MH, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 34...
12H, 140M, 140M 2, 14M, 160M, 160M 2, 16G, 16H NA, 16M, 2290, 2390, 2391, 2491, 24H, 24M, 2590, 3176, 330C, 330C FM, 330C L, 330C MH, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 34...
2210072
REGULATOR AS-VOLTAGE
216, 236, 247, 267, 287, D3G, D4G, D5G
216, 236, 247, 267, 287, D3G, D4G, D5G
2495541
REGULATOR-WATER TEMPERATURE
216, 216B, 216B3, 226B, 226B3, 232B, 242B, 247B, 247B3, 257B, 3013C, 3024, 3024C, AP-255E, BB-621C, C1.1, C1.5, C2.2, CB-22, CB-334E, CB-34, CB22B, CB24B, CB32B, CB34B, CB34B XW, CC24B, CC34B
216, 216B, 216B3, 226B, 226B3, 232B, 242B, 247B, 247B3, 257B, 3013C, 3024, 3024C, AP-255E, BB-621C, C1.1, C1.5, C2.2, CB-22, CB-334E, CB-34, CB22B, CB24B, CB32B, CB34B, CB34B XW, CC24B, CC34B
2306263
REGULATOR-WATER TEMPERATURE
216, 216B, 232B, 242B
216, 216B, 232B, 242B
2519336
REGULATOR-WATER TEMPERATURE
216, 228, 236, 247, 267, 3034, 906
216, 228, 236, 247, 267, 3034, 906
1503370
REGULATOR AS-XMSN TEMPERATURE
416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D
416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D
2542268
REGULATOR AS-WATER TEMPERATURE
3054C, 3054E, C3.3, C4.4, CB-434D, M313C, M315C, TH210, TH215
3054C, 3054E, C3.3, C4.4, CB-434D, M313C, M315C, TH210, TH215
2354960
REGULATOR AS-WATER TEMPERATURE
236B, 236B3, 242B3, 246C, 252B, 252B3, 256C, 257B3, 259B3, 262C, 262C2, 267B, 268B, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 3044C, 904B, 904H, 906, 906H, 907H, 908, 908H,...
236B, 236B3, 242B3, 246C, 252B, 252B3, 256C, 257B3, 259B3, 262C, 262C2, 267B, 268B, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 3044C, 904B, 904H, 906, 906H, 907H, 908, 908H,...
2542267
REGULATOR GP-TEMPERATURE
3054C, 3054E, 312D2, 312D2 GC, 312D2 L, 313D2, 313D2 LGP, 318D2 L, 414E, 416D, 416E, 416F, 420D, 420E, 420F, 422E, 422F, 424D, 428D, 428E, 428F, 430D, 430E, 430F, 432D, 432E, 432F, 434E, 434F, 442D, 4...
3054C, 3054E, 312D2, 312D2 GC, 312D2 L, 313D2, 313D2 LGP, 318D2 L, 414E, 416D, 416E, 416F, 420D, 420E, 420F, 422E, 422F, 424D, 428D, 428E, 428F, 430D, 430E, 430F, 432D, 432E, 432F, 434E, 434F, 442D, 4...
2256908
REGULATOR-WATER TEMPERATURE
3054C, 3054E, 315C, AP-650B, AP-800D, CP-433E, CS-323C, CS-423E, CS-433E, CS-533E, PF-300C, PS-150C, PS-360C, TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
3054C, 3054E, 315C, AP-650B, AP-800D, CP-433E, CS-323C, CS-423E, CS-433E, CS-533E, PF-300C, PS-150C, PS-360C, TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
1592713
REGULATOR AS-ALTERNATOR
446B, 446D
446B, 446D
3696662
REGULATOR AS
120H, 120K, 120K 2, 12H, 12K, 12M, 135H, 140G, 140K, 140K 2, 140M, 140M 2, 160K, 160M, 160M 2, 2290, 2390, 2391, 2491, 2590, 3126, 3126B, 3126E, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L, 324D ...
120H, 120K, 120K 2, 12H, 12K, 12M, 135H, 140G, 140K, 140K 2, 140M, 140M 2, 160K, 160M, 160M 2, 2290, 2390, 2391, 2491, 2590, 3126, 3126B, 3126E, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L, 324D ...