2K4310 REINFORCEMENT Caterpillar parts
14G, 14H, 14H NA, 14M, 16G, 16H, 16H NA, 16M, 951, 955, 977, 977D, 977H, 988, D6H, D6H XL, D6H XR, D6R, D6R II
Rating:
Alternative (cross code) number:
CA2K4310
2K-4310
2K4310
CA2K4310
2K-4310
2K4310
Weight: 2 pounds 1 kg.
MOTOR GRADER, WHEEL LOADER,
Compatible equipment models: 2K4310:
Information:
Test Procedure
System Operation
An energized input closes the N.O. contacts. An energized input opens the N.C. contacts. Digital modules are used to determine whether a circuit is ON/OFF. A number of modules are available. The most common modules have sixteen channels.
Illustration 1 g00563503
Diagram of the programmable logic controller
Illustration 2 g00563591
Schematic of the discrete inputFunctional Test
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 5/04.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Proceed to 2.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
Verify the value of the channel.
Get on-line with the PLC.
Locate the software address for the channel.The results of the preceding procedure are in the following list:
The channel has a software address. Proceed to 3.
The channel does not have a software address. Replace the module. Verify that the repair resolves the problem. Refer to Maintenance Procedure, "Input Module and Output Module - Replace". Stop.
Apply the rated voltage.
Apply the rated voltage to the channel.
Verify that the address changed from zero to one.Note: The LED will illuminate when the rated voltage is applied to the channel.The results of the preceding procedure are in the following list:
The software address value changes. The module is functioning normally. Stop.
The software address value does not change. the module is not functioning normally. Replace the module. Verify that the repair resolves the problem. Refer to Maintenance Procedure, "Input Module and Output Module - Replace". Stop.
System Operation
An energized input closes the N.O. contacts. An energized input opens the N.C. contacts. Digital modules are used to determine whether a circuit is ON/OFF. A number of modules are available. The most common modules have sixteen channels.
Illustration 1 g00563503
Diagram of the programmable logic controller
Illustration 2 g00563591
Schematic of the discrete inputFunctional Test
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 5/04.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Proceed to 2.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
Verify the value of the channel.
Get on-line with the PLC.
Locate the software address for the channel.The results of the preceding procedure are in the following list:
The channel has a software address. Proceed to 3.
The channel does not have a software address. Replace the module. Verify that the repair resolves the problem. Refer to Maintenance Procedure, "Input Module and Output Module - Replace". Stop.
Apply the rated voltage.
Apply the rated voltage to the channel.
Verify that the address changed from zero to one.Note: The LED will illuminate when the rated voltage is applied to the channel.The results of the preceding procedure are in the following list:
The software address value changes. The module is functioning normally. Stop.
The software address value does not change. the module is not functioning normally. Replace the module. Verify that the repair resolves the problem. Refer to Maintenance Procedure, "Input Module and Output Module - Replace". Stop.
Cat SIS web machinery list:
Parts reinforcement Caterpillar catalog:
7S5913
REINFORCEMENT
120, 120G, 130G, 140G, 14E, 3304, 3304B, 3306, 515, 517, 518C, 525, 527, 561C, 627, 65C, 816F, 941, 950, 966C, 966F, 977K, 980B, D300E, D4D, D4E SR, D4H, D4H XL, D4HTSK III, D5, D5H, D5H XL, D5HTSK II...
120, 120G, 130G, 140G, 14E, 3304, 3304B, 3306, 515, 517, 518C, 525, 527, 561C, 627, 65C, 816F, 941, 950, 966C, 966F, 977K, 980B, D300E, D4D, D4E SR, D4H, D4H XL, D4HTSK III, D5, D5H, D5H XL, D5HTSK II...
2K4309
REINFORCEMENT
14G, 14H, 14H NA, 14M, 16G, 16H, 16H NA, 16M, 951, 955, 977, 977D, 977H, 988, D6H, D6H XL, D6H XR, D6R, D6R II
14G, 14H, 14H NA, 14M, 16G, 16H, 16H NA, 16M, 951, 955, 977, 977D, 977H, 988, D6H, D6H XL, D6H XR, D6R, D6R II
6Y1812
REINFORCEMENT
D6H, D6T XL
D6H, D6T XL
1J1120
REINFORCEMENT
977D, 977H, 977K
977D, 977H, 977K
3K5832
REINFORCEMENT
977H
977H
7D3532
REINFORCEMENT
16, 16G
16, 16G
2K4309
REINFORCEMENT
14G, 14H, 14H NA, 14M, 16G, 16H, 16H NA, 16M, 951, 955, 977, 977D, 977H, 988, D6H, D6H XL, D6H XR, D6R, D6R II
14G, 14H, 14H NA, 14M, 16G, 16H, 16H NA, 16M, 951, 955, 977, 977D, 977H, 988, D6H, D6H XL, D6H XR, D6R, D6R II
6B4241
REINFORCEMENT
215B, 225, 229, 621B
215B, 225, 229, 621B
1215566
REINFORCEMENT
M312, M313D, M315, M315C, M315D, M316C, M316D
M312, M313D, M315, M315C, M315D, M316C, M316D
1173405
REINFORCEMENT
325C, M318, M318C, M318C MH, M318D, M318D MH, M320, M322C, M322D, M322D MH
325C, M318, M318C, M318C MH, M318D, M318D MH, M320, M322C, M322D, M322D MH
7S5913
REINFORCEMENT
120, 120G, 130G, 140G, 14E, 3304, 3304B, 3306, 515, 517, 518C, 525, 527, 561C, 627, 65C, 816F, 941, 950, 966C, 966F, 977K, 980B, D300E, D4D, D4E SR, D4H, D4H XL, D4HTSK III, D5, D5H, D5H XL, D5HTSK II...
120, 120G, 130G, 140G, 14E, 3304, 3304B, 3306, 515, 517, 518C, 525, 527, 561C, 627, 65C, 816F, 941, 950, 966C, 966F, 977K, 980B, D300E, D4D, D4E SR, D4H, D4H XL, D4HTSK III, D5, D5H, D5H XL, D5HTSK II...
6Y1812
REINFORCEMENT
D6H, D6T XL
D6H, D6T XL
1U1440
REINFORCEMENT
834B, D7E, D7H, D7R, D7R II
834B, D7E, D7H, D7R, D7R II
3G5352
REINFORCEMENT
D7E, D7H, D7R, D7R II, D7R XR
D7E, D7H, D7R, D7R II, D7R XR
5J4982
REINFORCEMENT
D4E SR, D9T
D4E SR, D9T
3J5026
REINFORCEMENT
D6E, D6E SR, D6G SR, D6G2 XL
D6E, D6E SR, D6G SR, D6G2 XL
8P2944
REINFORCEMENT AS
D5B, D5E, D6D, D6D SR, D6E, D6E SR
D5B, D5E, D6D, D6D SR, D6E, D6E SR