1418466 RETAINER Caterpillar parts
24H, 30/30, 611, 615C, 814F, 815B, 815F, 816F, 824G, 824G II, 825G, 825G II, 826G, 826G II, 834G, 836G, 844, 844H, 844K, 854G, 854K, 936F, 950F, 950F II, 960F, 966F, 966F II, 970F, 980C, 980F, 980F II...
Rating:
Alternative (cross code) number:
CA1418466
141-8466
1418466
CA1418466
141-8466
1418466
Weight: 0.04 pounds 0 kg.
ARTICULATED TRUCK, WHEEL TRACTOR,
Compatible equipment models: 1418466:
Information:
Introduction
The boom hydraulic circuit contains a regeneration circuit. This regeneration circuit allows the return oil from the head end of the boom cylinders to be supplied to the rod end of the boom cylinders during the BOOM DOWN operation. The proportional reducing valve (PRV) for the boom regeneration valve controls the amount of pilot pressure from the joystick to the boom down regeneration valve. The PRV for the boom regeneration valve is controlled by the machine ECM.Preliminary Test
Testing and Adjusting, "Relief Valve (Pilot) - Test and Adjust"
Testing and Adjusting, "Solenoid Valve (Proportional Reducing) - Calibrate (Power Shift Pressure)"
Testing and Adjusting, "Solenoid Valve (Proportional Reducing) - Calibrate (Negative Flow Control)"Required Tools
Illustration 1 g02571852
Tooling (A) 198-4240 Digital Pressure Indicator Gp
Table 1
Tool Item Qty Part Number Description
A 198-4240 Digital Pressure Indicator Gp
A1 1 198-4234 Indicator
A2 1 198-4237 Pressure Sensor 3447 kPa (500 psi)
A3 1 198-4236 Extension Cable Machine Preparation
Position the machine on level ground.
Stop the engine
Release the pressure in the hydraulic system. Refer to Testing and Adjusting, "System Pressure - Release".
Illustration 2 g02141845
(1) Pressure tap for the proportional reducing valve (boom regeneration valve)
(2) Pilot manifold
(3) Panel
Connect a 3447 kPa (500 psi) pressure sensor to the pressure tap for the boom regeneration valve. The pressure tap for the boom regeneration valve is located below the main control valve. The pressure tap can be accessed through panel (3). Calibration Procedure
Start the engine.
Increase the hydraulic oil temperature to 55° 5°C (131° 9°F).
Place the hydraulic activation lever in the UNLOCK position.
Place the machine implements on the ground at maximum reach.
Enter the service mode. Input the password "9992".
Illustration 3 g02550247
Select "Boom Down Regen Valve" from the "Calibrations" menu.
Press the OK key in order to start the calibration. The engine RPM will automatically drop to the equivalence of engine speed dial 1.
Confirm the notes on the monitor display. Set up the test conditions in accordance with the instructions. Press the OK key.
Move the joystick for BOOM DOWN to the full down position and hold the joystick in this position.
Illustration 4 g02550277
Use the arrows to adjust the pressure until the pressure reading for the boom regeneration valve is at 500 50 kPa (73 7 psi). Press the OK key.
Move the joystick for BOOM DOWN to the NEUTRAL position.
Confirm notes on the monitor display. Set up the test conditions in accordance with the instructions. Press the OK key.
Move the joystick for BOOM DOWN to the full down position and hold the joystick in this position.
Illustration 5 g02550318
Use the arrows to adjust the pressure until the pressure reading for the boom regeneration valve is at 2500 50 kPa (363 7 psi). Press the OK key.
Move the joystick for BOOM DOWN to the NEUTRAL position.
Illustration 6 g02550516
If calibration was successful and no errors occurred, the display will indicate that the calibration is complete.
Illustration 7 g02550596
The "Error" screen will be displayed on the monitor if an error occurs. The process of calibration will not be saved and the process must be restarted.
The boom hydraulic circuit contains a regeneration circuit. This regeneration circuit allows the return oil from the head end of the boom cylinders to be supplied to the rod end of the boom cylinders during the BOOM DOWN operation. The proportional reducing valve (PRV) for the boom regeneration valve controls the amount of pilot pressure from the joystick to the boom down regeneration valve. The PRV for the boom regeneration valve is controlled by the machine ECM.Preliminary Test
Testing and Adjusting, "Relief Valve (Pilot) - Test and Adjust"
Testing and Adjusting, "Solenoid Valve (Proportional Reducing) - Calibrate (Power Shift Pressure)"
Testing and Adjusting, "Solenoid Valve (Proportional Reducing) - Calibrate (Negative Flow Control)"Required Tools
Illustration 1 g02571852
Tooling (A) 198-4240 Digital Pressure Indicator Gp
Table 1
Tool Item Qty Part Number Description
A 198-4240 Digital Pressure Indicator Gp
A1 1 198-4234 Indicator
A2 1 198-4237 Pressure Sensor 3447 kPa (500 psi)
A3 1 198-4236 Extension Cable Machine Preparation
Position the machine on level ground.
Stop the engine
Release the pressure in the hydraulic system. Refer to Testing and Adjusting, "System Pressure - Release".
Illustration 2 g02141845
(1) Pressure tap for the proportional reducing valve (boom regeneration valve)
(2) Pilot manifold
(3) Panel
Connect a 3447 kPa (500 psi) pressure sensor to the pressure tap for the boom regeneration valve. The pressure tap for the boom regeneration valve is located below the main control valve. The pressure tap can be accessed through panel (3). Calibration Procedure
Start the engine.
Increase the hydraulic oil temperature to 55° 5°C (131° 9°F).
Place the hydraulic activation lever in the UNLOCK position.
Place the machine implements on the ground at maximum reach.
Enter the service mode. Input the password "9992".
Illustration 3 g02550247
Select "Boom Down Regen Valve" from the "Calibrations" menu.
Press the OK key in order to start the calibration. The engine RPM will automatically drop to the equivalence of engine speed dial 1.
Confirm the notes on the monitor display. Set up the test conditions in accordance with the instructions. Press the OK key.
Move the joystick for BOOM DOWN to the full down position and hold the joystick in this position.
Illustration 4 g02550277
Use the arrows to adjust the pressure until the pressure reading for the boom regeneration valve is at 500 50 kPa (73 7 psi). Press the OK key.
Move the joystick for BOOM DOWN to the NEUTRAL position.
Confirm notes on the monitor display. Set up the test conditions in accordance with the instructions. Press the OK key.
Move the joystick for BOOM DOWN to the full down position and hold the joystick in this position.
Illustration 5 g02550318
Use the arrows to adjust the pressure until the pressure reading for the boom regeneration valve is at 2500 50 kPa (363 7 psi). Press the OK key.
Move the joystick for BOOM DOWN to the NEUTRAL position.
Illustration 6 g02550516
If calibration was successful and no errors occurred, the display will indicate that the calibration is complete.
Illustration 7 g02550596
The "Error" screen will be displayed on the monitor if an error occurs. The process of calibration will not be saved and the process must be restarted.
Cat SIS web machinery list:
Parts retainer Caterpillar catalog:
1139609
RETAINER AS
345B II, 345C L, 350, 365B, 365B II, 365C, 365C L, 374D L, 375, 375 L, 385B, 385C, 385C L, 390D, 5080, 5110B, 5230, 988H, 988K, 990, 990 II, 990H, 992G
345B II, 345C L, 350, 365B, 365B II, 365C, 365C L, 374D L, 375, 375 L, 385B, 385C, 385C L, 390D, 5080, 5110B, 5230, 988H, 988K, 990, 990 II, 990H, 992G
2337150
RETAINER-G.E.T.
349E L, 349E L VG, 365B, 365B L, 365C, 365C L, 374D L, 385B, 385C, 385C FS, 385C L, 390D, 390D L, 990 II, 990H, 990K, 992G, 992K
349E L, 349E L VG, 365B, 365B L, 365C, 365C L, 374D L, 385B, 385C, 385C FS, 385C L, 390D, 390D L, 990 II, 990H, 990K, 992G, 992K
2209110
RETAINER-G.E.T.
322C, 324D, 324D L, 324D LN, 325C, 325D, 325D L, 330C, 330C L, 330D L, 330D LN, 345B II, 345C, 345C L, 345D L, 980G II, 980H, 980M, 988G, 988H
322C, 324D, 324D L, 324D LN, 325C, 325D, 325D L, 330C, 330C L, 330D L, 330D LN, 345B II, 345C, 345C L, 345D L, 980G II, 980H, 980M, 988G, 988H
1T1226
RETAINER-BEARING
24M, 69D, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 773F, 773G LRC, 773G OEM, 775B, 775D, 775F, 775G LRC, 775G OEM, D350E, D350E II, D35HP, D400, D400E, D400E II
24M, 69D, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 773F, 773G LRC, 773G OEM, 775B, 775D, 775F, 775G LRC, 775G OEM, D350E, D350E II, D35HP, D400, D400E, D400E II
8X4999
RETAINER
725, 730, D250B, D250E, D250E II, D300D, D300E
725, 730, D250B, D250E, D250E II, D300D, D300E
6Y1202
RETAINER AS
375, 854G, D10N, D10R, D10T, D10T2, D11N, D11R, D11T, D9R, D9T
375, 854G, D10N, D10R, D10T, D10T2, D11N, D11R, D11T, D9R, D9T
6Y1205
RETAINER AS
374D L, D11N, D11R, D11T, D9L
374D L, D11N, D11R, D11T, D9L
7T2654
RETAINER
844, 844H, 844K, D8L
844, 844H, 844K, D8L
9P9990
RETAINER-GUARD
D10, D11N, D11R, D11T
D10, D11N, D11R, D11T
1069037
RETAINER
854G, 854K, D11N, D11R, D11T
854G, 854K, D11N, D11R, D11T
6J5986
RETAINER
814S, 824S, 854G, 854K, D10N, D10R, D10T, D10T2, D11N, D11R, D11T
814S, 824S, 854G, 854K, D10N, D10R, D10T, D10T2, D11N, D11R, D11T
3S3225
RETAINER-BAR
815, 824B, 825C, 825G, 825G II, 825H, 825K, 834
815, 824B, 825C, 825G, 825G II, 825H, 825K, 834
1459080
RETAINER
30/30, DEUCE
30/30, DEUCE
1335037
RETAINER-SPRING
30/30, 3116, 3126, 938F, 962G, DEUCE
30/30, 3116, 3126, 938F, 962G, DEUCE
4W5723
RETAINER-FILTER
3512, D11N
3512, D11N
5Y1011
RETAINER
3408B
3408B
5Y1007
RETAINER
3408B
3408B
5Y0094
RETAINER
3408B
3408B
1437620
RETAINER
30/30, DEUCE
30/30, DEUCE
6P9786
RETAINER
24H, 30/30, 517, 527, 561M, 578, 583R, 587R, 589, 611, 613C, 613C II, 613G, 615, 615C, 814B, 814F, 815B, 815F, 816F, 824G, 825G, 826C, 826G, 834B, 836, 844, 844H, 844K, 854G, 854K, 910, 916, 926, 931B...
24H, 30/30, 517, 527, 561M, 578, 583R, 587R, 589, 611, 613C, 613C II, 613G, 615, 615C, 814B, 814F, 815B, 815F, 816F, 824G, 825G, 826C, 826G, 834B, 836, 844, 844H, 844K, 854G, 854K, 910, 916, 926, 931B...
8M4409
RETAINER
30/30, 517, 527, 561M, 561N, 589, 611, 613G, 615C, 651, 657, 666, 772, 814B, 814F, 814F II, 815B, 815F, 815F II, 816F, 816F II, 926, 936, 936F, 950B, 950F, 950F II, 960F, 966D, 966F, 966F II, 966G, 96...
30/30, 517, 527, 561M, 561N, 589, 611, 613G, 615C, 651, 657, 666, 772, 814B, 814F, 814F II, 815B, 815F, 815F II, 816F, 816F II, 926, 936, 936F, 950B, 950F, 950F II, 960F, 966D, 966F, 966F II, 966G, 96...
1T1281
RETAINER-BEARING
30/30, 527, 583T, 611, 615, 615C, 631E, 637D, 637E, 637G, 725, 725C, 730, 735, 814B, 815B, 966D, 966F, 980K, 980K HLG, 980M, 986H, AD30, C9, D250D, D250E, D250E II, D25C, D25D, D300B, D300E, D300E II,...
30/30, 527, 583T, 611, 615, 615C, 631E, 637D, 637E, 637G, 725, 725C, 730, 735, 814B, 815B, 966D, 966F, 980K, 980K HLG, 980M, 986H, AD30, C9, D250D, D250E, D250E II, D25C, D25D, D300B, D300E, D300E II,...
8P8552
RETAINER
30/30, 611, 615, 615C, D250D, D250E, D250E II, D25C, D25D, D300B, D300E, D300E II, DEUCE, R1600, R1600G, R1600H
30/30, 611, 615, 615C, D250D, D250E, D250E II, D25C, D25D, D300B, D300E, D300E II, DEUCE, R1600, R1600G, R1600H
9U9374
RETAINER
30/30, AD30, D250E, D250E II, D300E, D300E II, D350E, D350E II, D400E, DEUCE
30/30, AD30, D250E, D250E II, D300E, D300E II, D350E, D350E II, D400E, DEUCE