1U2067 RETAINER Caterpillar parts
950B, 963, 963B, 966D, 973, 980C
Rating:
Alternative (cross code) number:
CA1U2067
1U-2067
1U2067
CA1U2067
1U-2067
1U2067
Weight: 0.03 pounds 0 kg.
TRACK LOADER, WHEEL LOADER,
Compatible equipment models: 1U2067:
Information:
Overview of MCS A&P Network
Illustration 1 g03330293
Illustration 1 shows the typical layout of the MCS alarm and protection system. The following units are available in MCS alarm and protection system:
MCS Controller (DCU 410)
Shut down unit (SDU 410)
Remote input/output module (RIO 410)
Power analyzer module (RIO 425)
Remote equipment interface (RP 410)MCS Controller (DCU 410) - The MCS controls and monitors the engine. One panel is required for each engine. The MCS controller engine control unit utilizes a color screen and buttons for user interaction.Shutdown Unit (SDU 410) - The SDU is the safety unit, which is required in class installation. The unit is completely self contained and is separate from the MCS controller. However, the MCS controller communicates with the SDU via the RS-485 communication link.Remote Input/Output (RIO 410) - The RIO is an expansion I/O unit, which allows a maximum of four RIO units to be connected to one MCS controller. The MCS controller communicates with the RIO over an RS-485 link.Power analyzer module (PAM) generator interface unit (RIO 425) - The PAM generator interface unit is linked to the MCS controller. The MCS controller detects the generator interface unit automatically. A new page is made available on the MCS controller, and on the remote panel, that displays the following generator parameters: phase voltages, phase currents, frequency, power and total harmonic distortion (THD).Remote Equipment Interface (RP 410) - The REI can monitor and control a maximum of eight MCS controllers that are in the network. Several REI units can monitor the same engine, or one REI can monitor separate engines. The REI communicates with the MCS controller via Ethernet. Each REI can also monitor up to four cameras.MCS Controller Capability
The following items are a list of the functionality and content highlights of the MCS controller:
Dual 24V redundant supply
145 mm (5.7 inch) color screen
4 PT100 input channels
Four 4-20mA analog input channels
Eight switch input channels
One tachometer input channel
One ethernet Modbus RTU
1 RS-485 Modbus RTU
1 J1939 CAN interface
1 CANopen interface
Two configurable relay outputs
Four configurable 24V outputs
One common alarm relay
Remote panel link (TCP/IP)
SDU link
RIO I/O link
MK-14 link
Internal web server configuration and support
Password protected configuration
User selectable units of measure
Multilingual
Sophisticated alarm configuration
Supply voltage monitoring and alarm
Extensive alarm list with ECM diagnostics
Fault codes translated into messages in selected language
Log of all events
Prelube functionality that is configurable
Service interval timers
Ambient light sensor for automatic backlight adjustment
Calculated fuel consumption values
Certified by major classification societiesThe I/O capacity of the MCS controller can be expanded with the use of 1 or more of the RIO units. Refer to "RIO Expansion I/O"
Table 1
Signal Type     Standard     Maximum    
4-20mA     4     40    
PT100     4     36    
Switch inputs     8     24    
Thermocouples     0     8    
Configurable relays     2     24    
Configurable 24V output     4     12    
0-5V inputs     0     4    
J1939 channels     20 pages     20 pages    Precautions Regarding Classed Systems
In a classed and type approved installation, please adhere to the following guidelines.
Illustration 1 g03330293
Illustration 1 shows the typical layout of the MCS alarm and protection system. The following units are available in MCS alarm and protection system:
MCS Controller (DCU 410)
Shut down unit (SDU 410)
Remote input/output module (RIO 410)
Power analyzer module (RIO 425)
Remote equipment interface (RP 410)MCS Controller (DCU 410) - The MCS controls and monitors the engine. One panel is required for each engine. The MCS controller engine control unit utilizes a color screen and buttons for user interaction.Shutdown Unit (SDU 410) - The SDU is the safety unit, which is required in class installation. The unit is completely self contained and is separate from the MCS controller. However, the MCS controller communicates with the SDU via the RS-485 communication link.Remote Input/Output (RIO 410) - The RIO is an expansion I/O unit, which allows a maximum of four RIO units to be connected to one MCS controller. The MCS controller communicates with the RIO over an RS-485 link.Power analyzer module (PAM) generator interface unit (RIO 425) - The PAM generator interface unit is linked to the MCS controller. The MCS controller detects the generator interface unit automatically. A new page is made available on the MCS controller, and on the remote panel, that displays the following generator parameters: phase voltages, phase currents, frequency, power and total harmonic distortion (THD).Remote Equipment Interface (RP 410) - The REI can monitor and control a maximum of eight MCS controllers that are in the network. Several REI units can monitor the same engine, or one REI can monitor separate engines. The REI communicates with the MCS controller via Ethernet. Each REI can also monitor up to four cameras.MCS Controller Capability
The following items are a list of the functionality and content highlights of the MCS controller:
Dual 24V redundant supply
145 mm (5.7 inch) color screen
4 PT100 input channels
Four 4-20mA analog input channels
Eight switch input channels
One tachometer input channel
One ethernet Modbus RTU
1 RS-485 Modbus RTU
1 J1939 CAN interface
1 CANopen interface
Two configurable relay outputs
Four configurable 24V outputs
One common alarm relay
Remote panel link (TCP/IP)
SDU link
RIO I/O link
MK-14 link
Internal web server configuration and support
Password protected configuration
User selectable units of measure
Multilingual
Sophisticated alarm configuration
Supply voltage monitoring and alarm
Extensive alarm list with ECM diagnostics
Fault codes translated into messages in selected language
Log of all events
Prelube functionality that is configurable
Service interval timers
Ambient light sensor for automatic backlight adjustment
Calculated fuel consumption values
Certified by major classification societiesThe I/O capacity of the MCS controller can be expanded with the use of 1 or more of the RIO units. Refer to "RIO Expansion I/O"
Table 1
Signal Type     Standard     Maximum    
4-20mA     4     40    
PT100     4     36    
Switch inputs     8     24    
Thermocouples     0     8    
Configurable relays     2     24    
Configurable 24V output     4     12    
0-5V inputs     0     4    
J1939 channels     20 pages     20 pages    Precautions Regarding Classed Systems
In a classed and type approved installation, please adhere to the following guidelines.
Caterpillar parts catalog:
Parts retainer Caterpillar catalog:
4T3171
RETAINER
963, 963B
963, 963B
4T2598
RETAINER
963, 963B, 963C, 973, 973C
963, 963B, 963C, 973, 973C
9J8049
RETAINER
943, 953, 963, 963B, 973
943, 953, 963, 963B, 973
4T0956
RETAINER
943, 953, 953B, 963B, 973
943, 953, 953B, 963B, 973
3G2713
RETAINER
943, 953, 963, 963B, 973
943, 953, 963, 963B, 973
9J8718
RETAINER
943, 953, 963, 963B, 973
943, 953, 963, 963B, 973
7P7051
RETAINER
943, 953, 953B, 963, 963B, 973
943, 953, 953B, 963, 963B, 973
9T2831
RETAINER
933C, 939C, 963B, 963C, 973, 973C, D3C III, D4C III, D5C III
933C, 939C, 963B, 963C, 973, 973C, D3C III, D4C III, D5C III
9T2832
RETAINER
933C, 939C, 963B, 963C, 973, 973C, D3C III, D4C III, D5C III
933C, 939C, 963B, 963C, 973, 973C, D3C III, D4C III, D5C III
3G8476
RETAINER
943, 953, 963, 963B, 973
943, 953, 963, 963B, 973
3G8477
RETAINER
943, 953, 963, 963B, 973
943, 953, 963, 963B, 973
1U2070
RETAINER
623E, 950B, 963, 963B, 966D, 973, 980C
623E, 950B, 963, 963B, 966D, 973, 980C