3699538 RETAINER-SEAL Caterpillar parts
Rating:
Alternative (cross code) number:
CA3699538
369-9538
3699538
CA3699538
369-9538
3699538
Weight: 12 pounds 5 kg.
Information:
Cat Datalink Boost Function Enable Status
The PL1000T contains special circuitry that can provide a boost function for the Cat Datalink. When this boost function is enabled, the Cat Datalink wiring harness length limitations are extended to 305 m (1000 ft).
Enabled - Cat Datalink harness length limitation is 305 m (1000 ft).
Disabled - Cat Datalink harness length limitation is 31 m (100 ft).Note: Enabling the boost function when Cat Datalink is less than 31 m (100 ft) can cause communication failures. Only enable the boost function when harness lengths greater than 31 m (100 ft) are required. When multiple PL1000Ts are connected to the same Cat Datalink, "CDL Boost" should be enabled on only one of the devices. Enabling "CDL Boost" on multiple PL1000Ts connected to the same Cat Datalink network will prevent normal communications.Cat Datalink over J1939 Tunnel Function Enable Status
The Tunnel Function Enable Status is a specialized feature for integration of 3500B Series II Caterpillar engines. Tunnel Function Enable Status is used for multiple engine connection to a single display device on Cat Datalink. The engine "Application and Integration guide" provides information on whether this feature is required in the application.CAN Extension Bridge Function Enable Status
Possible Values
Enabled
Disabled (Default)When this feature is enabled, the PL1000T will bridge communications between CAN port 1 and the RS-485 connection, as well as between CAN port 2 and the RS-485 connection.J1939 Bridge Function Enable Status
Possible Values
Enabled
Disabled (Default)When this feature is enabled, the PL1000T will bridge communications between CAN port 1 and CAN port 2.Note: The operation of the J"1939 Bridge" and "CAN Extension Bridge" features of the PL1000T is mutually exclusive. If the "J1939 Bridge" functionality is enabled, the "CAN Extension Bridge" functionality will be automatically "Disabled". Therefore, if the "J1939 Bridge" functionality is "Disabled", the "CAN Extension Bridge" functionality will be automatically "Enabled". Refer to Systems Operation, "General Information" for more information on feature compatibility.Customer Communications Module (CCM) Configuration
CCM Function Port Selection
Possible values:
Disabled
Serial Port 1
Serial Port 2Possible Values:
300
600
1200
2400
4800
9600
19200
38400CCM Stop Bits
Possible Values
1
2CCM Data Bits
Possible Values
7
8CCM Parity
Possible Values:
Even
Mark
None
Odd
SpaceCCM Protocol Auto-Detect Enable Status
Possible Values
Enabled
DisabledCCM Protocol Configuration
Possible Values
M5X
M50CCM Unit Configuration
Possible Values
Primary
ServiceCCM Password Protection Enable Status
Possible Values
Enabled
DisabledCCM Function Baud Rate Change Enabled Status
Possible Values
Enabled
DisabledCCM Connection Type Configuration
Possible Values
Direct
Modem
Table 1
CCM Example Message Table    
Description and Command String sent to CCM     Response from CCM    
Set access security to Level 1 using password "ABCDEF123"
"5000340C0061AA874142434445313233F9"     "5001350B61AA874142434445313233F8"    
Set access security Level 2 using password "XYZ12345"
5000340C0061AA88585955A3132333435D3     5001350B61AA8858595A3132333435D2    
Set access security to Level 3 using password "5000340C0061AA8941424358595A3132A8"     "5001350B61AA8941424358595A3132A7"    
"Standard Broadcast List 01" Setup for Parameters ($40, $44, $54, $F118, $F50E, $F509, $F119, $F58E)
"5000A13150124030020004000440054F118F50eF509F119F58ED1"     "50015010099"    
Activate Standard Broadcast List 01
"50001101019D"     "500115010099"    
Deactivate Standard Broadcast List 01
"50001201019C"     "50011501099"    
Advanced Broadcast List 01 Setup for Parameters ($40, $44, $54, $F118, $F50E, $F509, $F119, $F58E)
"50001E1F012401000000000000400000044000054"
"00F11800F50900F58EDE"     "50011F0D1E012401000000000845150000DD"    
Activate Advanced Broadcast List 01
"50001C010192"     "5001F0D1C012401000000000845150000DF"    
Deactivate Advanced Broadcast List 01
"50001D010191"     "5001F0DFD012401000000000845150000DE"    
Activate Event Broadcasts
"50008109240000AAFA0E0101004E"     "5001850B24000000AAFA0E0001010047"    
Deactivate Event Broadcasts
"50008109000000AAFA0E02010071"     "5001850B00000000AAFA0E000201006A"    
Activate Diagnostics Broadcasts
"50008109000000AAFA0D02010072"     "5001850B00000000AAFA0D000201006B"  
The PL1000T contains special circuitry that can provide a boost function for the Cat Datalink. When this boost function is enabled, the Cat Datalink wiring harness length limitations are extended to 305 m (1000 ft).
Enabled - Cat Datalink harness length limitation is 305 m (1000 ft).
Disabled - Cat Datalink harness length limitation is 31 m (100 ft).Note: Enabling the boost function when Cat Datalink is less than 31 m (100 ft) can cause communication failures. Only enable the boost function when harness lengths greater than 31 m (100 ft) are required. When multiple PL1000Ts are connected to the same Cat Datalink, "CDL Boost" should be enabled on only one of the devices. Enabling "CDL Boost" on multiple PL1000Ts connected to the same Cat Datalink network will prevent normal communications.Cat Datalink over J1939 Tunnel Function Enable Status
The Tunnel Function Enable Status is a specialized feature for integration of 3500B Series II Caterpillar engines. Tunnel Function Enable Status is used for multiple engine connection to a single display device on Cat Datalink. The engine "Application and Integration guide" provides information on whether this feature is required in the application.CAN Extension Bridge Function Enable Status
Possible Values
Enabled
Disabled (Default)When this feature is enabled, the PL1000T will bridge communications between CAN port 1 and the RS-485 connection, as well as between CAN port 2 and the RS-485 connection.J1939 Bridge Function Enable Status
Possible Values
Enabled
Disabled (Default)When this feature is enabled, the PL1000T will bridge communications between CAN port 1 and CAN port 2.Note: The operation of the J"1939 Bridge" and "CAN Extension Bridge" features of the PL1000T is mutually exclusive. If the "J1939 Bridge" functionality is enabled, the "CAN Extension Bridge" functionality will be automatically "Disabled". Therefore, if the "J1939 Bridge" functionality is "Disabled", the "CAN Extension Bridge" functionality will be automatically "Enabled". Refer to Systems Operation, "General Information" for more information on feature compatibility.Customer Communications Module (CCM) Configuration
CCM Function Port Selection
Possible values:
Disabled
Serial Port 1
Serial Port 2Possible Values:
300
600
1200
2400
4800
9600
19200
38400CCM Stop Bits
Possible Values
1
2CCM Data Bits
Possible Values
7
8CCM Parity
Possible Values:
Even
Mark
None
Odd
SpaceCCM Protocol Auto-Detect Enable Status
Possible Values
Enabled
DisabledCCM Protocol Configuration
Possible Values
M5X
M50CCM Unit Configuration
Possible Values
Primary
ServiceCCM Password Protection Enable Status
Possible Values
Enabled
DisabledCCM Function Baud Rate Change Enabled Status
Possible Values
Enabled
DisabledCCM Connection Type Configuration
Possible Values
Direct
Modem
Table 1
CCM Example Message Table    
Description and Command String sent to CCM     Response from CCM    
Set access security to Level 1 using password "ABCDEF123"
"5000340C0061AA874142434445313233F9"     "5001350B61AA874142434445313233F8"    
Set access security Level 2 using password "XYZ12345"
5000340C0061AA88585955A3132333435D3     5001350B61AA8858595A3132333435D2    
Set access security to Level 3 using password "5000340C0061AA8941424358595A3132A8"     "5001350B61AA8941424358595A3132A7"    
"Standard Broadcast List 01" Setup for Parameters ($40, $44, $54, $F118, $F50E, $F509, $F119, $F58E)
"5000A13150124030020004000440054F118F50eF509F119F58ED1"     "50015010099"    
Activate Standard Broadcast List 01
"50001101019D"     "500115010099"    
Deactivate Standard Broadcast List 01
"50001201019C"     "50011501099"    
Advanced Broadcast List 01 Setup for Parameters ($40, $44, $54, $F118, $F50E, $F509, $F119, $F58E)
"50001E1F012401000000000000400000044000054"
"00F11800F50900F58EDE"     "50011F0D1E012401000000000845150000DD"    
Activate Advanced Broadcast List 01
"50001C010192"     "5001F0D1C012401000000000845150000DF"    
Deactivate Advanced Broadcast List 01
"50001D010191"     "5001F0DFD012401000000000845150000DE"    
Activate Event Broadcasts
"50008109240000AAFA0E0101004E"     "5001850B24000000AAFA0E0001010047"    
Deactivate Event Broadcasts
"50008109000000AAFA0E02010071"     "5001850B00000000AAFA0E000201006A"    
Activate Diagnostics Broadcasts
"50008109000000AAFA0D02010072"     "5001850B00000000AAFA0D000201006B"  
Caterpillar parts catalog:
Parts retainer Caterpillar catalog:
3685693
RETAINER-SEAL
Caterpillar
Caterpillar
3607410
RETAINER
Caterpillar
Caterpillar
3309779
RETAINER
Caterpillar
Caterpillar
2370478
RETAINER
Caterpillar
Caterpillar
5191124
RETAINER-BALL
Caterpillar
Caterpillar
5181890
RETAINER-BEARING
Caterpillar
Caterpillar
5025467
RETAINER-SEAL
Caterpillar
Caterpillar
4906608
RETAINER
Caterpillar
Caterpillar
4889216
RETAINER
Caterpillar
Caterpillar
4573317
RETAINER
Caterpillar
Caterpillar
4555324
RETAINER
Caterpillar
Caterpillar
4545901
RETAINER
Caterpillar
Caterpillar