3G2192 RETAINER-SEAL Caterpillar parts
153, 173B, 518, 518C, 528, 528B, 530B, 561H, 561M, 572G, 611, 613C, 613C II, 613G, 615C, 623B, 631C, 650B, 814, 814F, 814F II, 815, 815B, 815F, 815F II, 816F, 816F II, 824C, 825C, 844, 844H, 844K, 916...
Rating:
Alternative (cross code) number:
CA3G2192
3G-2192
3G2192
CA3G2192
3G-2192
3G2192
Weight: 0.01 pounds 0 kg.
ARTICULATED TRUCK, WHEEL TRACTOR-SCRAPER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$8.47
05 Nov 2022
US: Florida-Parts-Z
3G2192 - Retainer (Seal) for Caterpillar (CAT)
FIRST PRICE PARTS
FIRST PRICE PARTS
Information:
Conditions Which Generate This Code:
Illustration 1 g02305254
Schematic of the transfer case low range actuator solenoid.This diagnostic trouble code is associated with the transfer case low range actuator solenoid. The FMI 3 means that the ECU has determined that the voltage of the solenoid circuit is above normal.The possible causes of the diagnostic trouble code are listed:
The solenoid has failed.
The energize circuit of the solenoid is shorted to the +battery circuit.
The ECU has failed. The ECU failing is unlikely.Note: The following test procedure may create other diagnostic trouble codes. Ignore these created diagnostic trouble codes and clear these diagnostic trouble codes when the original diagnostic trouble code has been corrected. Ensure that the diagnostic trouble code of SPN 4045 FMI 3 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.System Response:The solenoid is engaged in a direct drive state.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the ECU.
At the machine harness connector for the ECU, measure the resistance from contact J2-2 (wire 778-BR) to all contacts that are used in the machine harness connectors for the ECU. Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-2 (778-BR) and the circuit that has a low resistance measurement. Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC TROUBLE CODE IS STILL ACTIVE.
Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.
Reconnect all harness connectors in order to make sure that the connectors are fully seated. Also, make sure that the clips for each connector are fastened.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the SPN 4045 FMI 3 is active.Expected Result:The SPN 4045 FMI 3 is active.Results:
YES - The SPN 4045 FMI 3 is active. The diagnostic trouble code has not been corrected.Repair: Check the circuit again. It is unlikely that the ECU has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic trouble code is not found, replace the ECU. Prior to replacing an ECU, always contact your dealership for possible consultation with Caterpillar. This consultation may greatly reduce repair time. See Testing and Adjusting, "Electronic Control Unit - Replace".STOP
NO - The SPN 4045 FMI 3 is not active. The diagnostic trouble code does not exist at this time. The initial diagnostic
Illustration 1 g02305254
Schematic of the transfer case low range actuator solenoid.This diagnostic trouble code is associated with the transfer case low range actuator solenoid. The FMI 3 means that the ECU has determined that the voltage of the solenoid circuit is above normal.The possible causes of the diagnostic trouble code are listed:
The solenoid has failed.
The energize circuit of the solenoid is shorted to the +battery circuit.
The ECU has failed. The ECU failing is unlikely.Note: The following test procedure may create other diagnostic trouble codes. Ignore these created diagnostic trouble codes and clear these diagnostic trouble codes when the original diagnostic trouble code has been corrected. Ensure that the diagnostic trouble code of SPN 4045 FMI 3 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.System Response:The solenoid is engaged in a direct drive state.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the ECU.
At the machine harness connector for the ECU, measure the resistance from contact J2-2 (wire 778-BR) to all contacts that are used in the machine harness connectors for the ECU. Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-2 (778-BR) and the circuit that has a low resistance measurement. Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC TROUBLE CODE IS STILL ACTIVE.
Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.
Reconnect all harness connectors in order to make sure that the connectors are fully seated. Also, make sure that the clips for each connector are fastened.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the SPN 4045 FMI 3 is active.Expected Result:The SPN 4045 FMI 3 is active.Results:
YES - The SPN 4045 FMI 3 is active. The diagnostic trouble code has not been corrected.Repair: Check the circuit again. It is unlikely that the ECU has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic trouble code is not found, replace the ECU. Prior to replacing an ECU, always contact your dealership for possible consultation with Caterpillar. This consultation may greatly reduce repair time. See Testing and Adjusting, "Electronic Control Unit - Replace".STOP
NO - The SPN 4045 FMI 3 is not active. The diagnostic trouble code does not exist at this time. The initial diagnostic
Cat SIS web machinery list:
Parts retainer Caterpillar catalog:
1T1226
RETAINER-BEARING
24M, 69D, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 773F, 773G LRC, 773G OEM, 775B, 775D, 775F, 775G LRC, 775G OEM, D350E, D350E II, D35HP, D400, D400E, D400E II
24M, 69D, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 773F, 773G LRC, 773G OEM, 775B, 775D, 775F, 775G LRC, 775G OEM, D350E, D350E II, D35HP, D400, D400E, D400E II
6Y1202
RETAINER AS
375, 854G, D10N, D10R, D10T, D10T2, D11N, D11R, D11T, D9R, D9T
375, 854G, D10N, D10R, D10T, D10T2, D11N, D11R, D11T, D9R, D9T
6Y1205
RETAINER AS
374D L, D11N, D11R, D11T, D9L
374D L, D11N, D11R, D11T, D9L
7T2654
RETAINER
844, 844H, 844K, D8L
844, 844H, 844K, D8L
6J5986
RETAINER
814S, 824S, 854G, 854K, D10N, D10R, D10T, D10T2, D11N, D11R, D11T
814S, 824S, 854G, 854K, D10N, D10R, D10T, D10T2, D11N, D11R, D11T
9W2380
RETAINER
D10N, D10R, D10T, D10T2, D8L, D9L, D9N, D9R, D9T
D10N, D10R, D10T, D10T2, D8L, D9L, D9N, D9R, D9T
9J6071
RETAINER
D10N, D10R, D9L
D10N, D10R, D9L
1298172
RETAINER
D10N, D10R, D10T, D10T2
D10N, D10R, D10T, D10T2
3S3225
RETAINER-BAR
815, 824B, 825C, 825G, 825G II, 825H, 825K, 834
815, 824B, 825C, 825G, 825G II, 825H, 825K, 834
6J5348
RETAINER
7A, 7S, D7G, D7G2
7A, 7S, D7G, D7G2
1U0209
RETAINER
D8L
D8L
4K5081
RETAINER
941, 951B, D4D, D4E, D4E SR
941, 951B, D4D, D4E, D4E SR
3F1546
RETAINER-SEAL
941, 951B, 955C, D4D, D4E, D4E SR
941, 951B, 955C, D4D, D4E, D4E SR
4K0212
RETAINER-SEAL
941, 951B, D4D, D4E, D4E SR
941, 951B, D4D, D4E, D4E SR
3F1554
RETAINER AS
941, 951B, 955C, D4D, D4E, D4E SR
941, 951B, 955C, D4D, D4E, D4E SR
7K7333
RETAINER-SEAL
941, 951B, D4D, D4E, D4E SR
941, 951B, D4D, D4E, D4E SR
2B9020
RETAINER-SPRING
931B, 933, 939, 941, 951B, 955C, 955H, 955K, 955L, D3, D3B, D3C III, D4C III, D4D, D4E, D4E SR, D5C, D5C III
931B, 933, 939, 941, 951B, 955C, 955H, 955K, 955L, D3, D3B, D3C III, D4C III, D4D, D4E, D4E SR, D5C, D5C III
6P5332
RETAINER
24H, 583T, 769C, 769D, 771C, 771D, 773B, 773D, 775B, 775D, 776C, 777F, 777G, 793D, 793F AC, 795F AC, 795F XQ, 797, 797B, 953, 963, 963B, 973, 994, 994D, AD40, AD45, AE40, AE40 II, D8R, D8R II, D8T
24H, 583T, 769C, 769D, 771C, 771D, 773B, 773D, 775B, 775D, 776C, 777F, 777G, 793D, 793F AC, 795F AC, 795F XQ, 797, 797B, 953, 963, 963B, 973, 994, 994D, AD40, AD45, AE40, AE40 II, D8R, D8R II, D8T
8G1560
RETAINER
963, 963B, 973
963, 963B, 973
7P9577
RETAINER
943, 953, 953B, 963, 963B, 973
943, 953, 953B, 963, 963B, 973
3V0684
RETAINER-BOOT
D4E, D4E SR
D4E, D4E SR
4K5037
RETAINER-SPRING
D4D, D4E, D4E SR
D4D, D4E, D4E SR
3V0019
RETAINER-BOOT
D4E, D4E SR
D4E, D4E SR