4F7021 RETAINER Caterpillar parts
955C, 955H, 977D, 977H, D315
Rating:
Alternative (cross code) number:
CA4F7021
4F-7021
4F7021
CA4F7021
4F-7021
4F7021
Weight: 0.02 pounds 0 kg.
Information:
OD
48.41
mm
THICKNESS
2.29
mm
TYPE
RECT SECT
MARINE ENGINE, TRACK LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 4F7021:
Information:
Electric Power GenerationC2.2 GEN SET (S/N: JK71-UP; JK81-UP)EngineC3.4B (S/N: CF61-UP; CF91-UP)Engine Package3.4B (S/N: CF61-UP; CF91-UP)Introduction
This Special Instruction provides troubleshooting instructions for certain XQ35 and XQ60 solar charger wiring.Do not perform any procedure in this Special Instruction until you have read the information and you understand the information.Important Safety Information
Work safely. Most accidents that involve product operation, maintenance, and repair are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs.A person must be alert to potential hazards. This person should also have the necessary training, skills, and tools to perform these functions properly.Safety precautions and warnings are provided in this instruction and on the product. If these hazard warnings are not heeded, bodily injury or death could occur to you or to other persons. Caterpillar cannot anticipate every possible circumstance that might involve a potential hazard.Ensure that the product will not be damaged or the product will not be made unsafe by the operation, lubrication, maintenance, or repair procedures used.Ground the equipment. Improper grounding will result in electrical current paths that are uncontrolled and unreliable. Uncontrolled electrical circuit paths can result in damage to the equipment. Uncontrolled electrical circuit paths can also cause electrical activity that may degrade the electronics and communications. Ensure that all grounds are secure and free of corrosion.
Do not operate or work on this machine unless you have read and understand the instructions and warnings in the Operation and Maintenance Manual. Failure to follow the instructions or heed the warnings could result in injury or death. Contact any Caterpillar dealer for replacement manuals. Proper care is your responsibility.
Only persons with training in electrical installations must carry connections to the generator.The generator must be wired correctly. A fire or electrocution could result from wiring that is incorrect.The generator is capable of generating high voltages. Ensure that the generator is not on while the connections are being made. Follow these steps in order to prevent accidental starting:
Isolate the machine from all external loads and sources.
Shut off the Engine.
Disconnect the battery supply lines and tape the leads.
Do not connect generator to a utility electrical distribution system unless it is isolated from the system. Electrical feedback into the distribution system can occur and could cause personal injury or death.Open and secure main distribution system switch, or if the connection is permanent, install a double throw transfer switch to prevent electrical feedback. Some generators are specifically approved by a utility to run in parallel with the distribution system and isolation may not be required. Always check with your utility as to the applicable circumstances.
Verify Solar Maintainer Array Wiring
Perform the following procedure to verify solar maintainer array wiring:
Illustration 1 g06262533
(1) Rear Controls Door
(2) Right Side Door
Open rear controls door and right side door.
Illustration 2 g06255551
Observe solar maintainer control module lamps to verify that solar maintainer is functioning:
Sunny day, charging = solid green, blinks off every 5 seconds.
Night time or improperly wired = OFF, blinks on every 5
This Special Instruction provides troubleshooting instructions for certain XQ35 and XQ60 solar charger wiring.Do not perform any procedure in this Special Instruction until you have read the information and you understand the information.Important Safety Information
Work safely. Most accidents that involve product operation, maintenance, and repair are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs.A person must be alert to potential hazards. This person should also have the necessary training, skills, and tools to perform these functions properly.Safety precautions and warnings are provided in this instruction and on the product. If these hazard warnings are not heeded, bodily injury or death could occur to you or to other persons. Caterpillar cannot anticipate every possible circumstance that might involve a potential hazard.Ensure that the product will not be damaged or the product will not be made unsafe by the operation, lubrication, maintenance, or repair procedures used.Ground the equipment. Improper grounding will result in electrical current paths that are uncontrolled and unreliable. Uncontrolled electrical circuit paths can result in damage to the equipment. Uncontrolled electrical circuit paths can also cause electrical activity that may degrade the electronics and communications. Ensure that all grounds are secure and free of corrosion.
Do not operate or work on this machine unless you have read and understand the instructions and warnings in the Operation and Maintenance Manual. Failure to follow the instructions or heed the warnings could result in injury or death. Contact any Caterpillar dealer for replacement manuals. Proper care is your responsibility.
Only persons with training in electrical installations must carry connections to the generator.The generator must be wired correctly. A fire or electrocution could result from wiring that is incorrect.The generator is capable of generating high voltages. Ensure that the generator is not on while the connections are being made. Follow these steps in order to prevent accidental starting:
Isolate the machine from all external loads and sources.
Shut off the Engine.
Disconnect the battery supply lines and tape the leads.
Do not connect generator to a utility electrical distribution system unless it is isolated from the system. Electrical feedback into the distribution system can occur and could cause personal injury or death.Open and secure main distribution system switch, or if the connection is permanent, install a double throw transfer switch to prevent electrical feedback. Some generators are specifically approved by a utility to run in parallel with the distribution system and isolation may not be required. Always check with your utility as to the applicable circumstances.
Verify Solar Maintainer Array Wiring
Perform the following procedure to verify solar maintainer array wiring:
Illustration 1 g06262533
(1) Rear Controls Door
(2) Right Side Door
Open rear controls door and right side door.
Illustration 2 g06255551
Observe solar maintainer control module lamps to verify that solar maintainer is functioning:
Sunny day, charging = solid green, blinks off every 5 seconds.
Night time or improperly wired = OFF, blinks on every 5
Caterpillar parts catalog:
Parts retainer Caterpillar catalog:
2M1778
RETAINER
12E, 1673, 1673B, 561B, 951B, 955H, 955K, 977H, 977K, D320A, D330A, D330B, D333A, D333B, D4D, G3306
12E, 1673, 1673B, 561B, 951B, 955H, 955K, 977H, 977K, D320A, D330A, D330B, D333A, D333B, D4D, G3306
8B9421
RETAINER
977D, D326F, D337, D342, D342C, D397D, G342C
977D, D326F, D337, D342, D342C, D397D, G342C
5F4061
RETAINER-SPRING
561B, 561C, 955C, 977D, D4D, D4E, D4E SR, D5, D5B, D5E, D6C, D6D, D6E SR, D7F, D7G
561B, 561C, 955C, 977D, D4D, D4E, D4E SR, D5, D5B, D5E, D6C, D6D, D6E SR, D7F, D7G
2M4668
RETAINER-GUARD
951B, 955H, 955K, 977H, 977K, 977L, D5, D5B, D6C, D6D, D6E, D6E SR, D6G SR, D7F, D7G, D7G2
951B, 955H, 955K, 977H, 977K, 977L, D5, D5B, D6C, D6D, D6E, D6E SR, D6G SR, D7F, D7G, D7G2
3F1972
RETAINER AS
561B, 561C, 561D, 955H, 977D, D5, D5B, D5E
561B, 561C, 561D, 955H, 977D, D5, D5B, D5E
1T0537
RETAINER
517, 518, 518C, 528, 613, 613B, 613C, 613C II, 814, 816, 910, 916, 920, 926, 930, 930R, 931B, 933, 936, 936F, 939, 941, 950, 955H, 966C, 977H, D250D, D3B, D3C II, D3C III, D4B, D4C III, D4D, D4E, D4H,...
517, 518, 518C, 528, 613, 613B, 613C, 613C II, 814, 816, 910, 916, 920, 926, 930, 930R, 931B, 933, 936, 936F, 939, 941, 950, 955H, 966C, 977H, D250D, D3B, D3C II, D3C III, D4B, D4C III, D4D, D4E, D4H,...
2B9020
RETAINER-SPRING
931B, 933, 939, 941, 951B, 955C, 955H, 955K, 955L, D3, D3B, D3C III, D4C III, D4D, D4E, D4E SR, D5C, D5C III
931B, 933, 939, 941, 951B, 955C, 955H, 955K, 955L, D3, D3B, D3C III, D4C III, D4D, D4E, D4E SR, D5C, D5C III
3F1554
RETAINER AS
941, 951B, 955C, D4D, D4E, D4E SR
941, 951B, 955C, D4D, D4E, D4E SR
3F1546
RETAINER-SEAL
941, 951B, 955C, D4D, D4E, D4E SR
941, 951B, 955C, D4D, D4E, D4E SR
3F1954
RETAINER
561B, 561C, 561D, 955H, 977D, D5, D5B
561B, 561C, 561D, 955H, 977D, D5, D5B
7M0476
RETAINER ASSEM.
561B, 955H, 955K, 955L, 977D
561B, 955H, 955K, 955L, 977D
7M0479
RETAINER
561B, 955H, 955K, 955L, 977D
561B, 955H, 955K, 955L, 977D
5H4228
RETAINER
D326F, D337F
D326F, D337F
9B0628
RETAINER
D342
D342
5H7129
RETAINER
583H, D342, D342C, D8H
583H, D342, D342C, D8H
1N3109
RETAINER
3512, G3512, G3520B, G3520E
3512, G3512, G3520B, G3520E
4B7295
RETAINER
583H, D342, D342C, G342C
583H, D342, D342C, G342C
2L3493
RETAINER
D379, D397D
D379, D397D
3H3131
RETAINER
D315, D342
D315, D342
2L1519
RETAINER
D342
D342
5H7339
RETAINER
D342, D342C, D8H
D342, D342C, D8H
5H7408
RETAINER
D326F, D337F
D326F, D337F