AVSPARE.COM
parts catalog

RETAINER 4Z8411 - Caterpillar



4Z8411 RETAINER Caterpillar parts RETAINER
Rating:
61
Alternative (cross code) number:
CA4Z8411
4Z-8411
4Z8411
Caterpillar 4Z8411 RETAINER
Weight: 10 pounds 4 kg.

Buy RETAINER 4Z8411 Caterpillar genuine, new aftermarket tractor parts with delivery

  For full view, you need register

Information:


Table 1
Diagnostic Trouble Codes    
J1939 Code    CDL Code    Code Description    Comments    
4215-3     267-3     Remote Shutdown Input : Voltage Above Normal     If both contacts from the ground level shutdown switch change to the same state and the engine is running, the engine will continue to run. The code is logged.    
4215-4     267-4     Remote Shutdown Input : Voltage Below Normal     If both contacts from the ground level shutdown switch change to the same state and the engine is running, the engine will continue to run. The code is logged.    
4215-31     E678 (1)     Ground Level Shutdown     The inputs from the ground level shutdown switch to the ECM have changed states.
The engine will shut down. The code is logged.    
4215-31     E678 (2)     Ground Level Shutdown     The inputs from the ground level shutdown switch to the ECM have changed states.
The engine will shut down. The code is logged.    
4215-31     E678 (3)     Ground Level Shutdown     The inputs from the ground level shutdown switch to the ECM have changed states.
The engine will shut down. The code is logged.    The shutdown switch will shut down the engine. The engine ECM remains active. Caterpillar Electronic Technician (ET) can be used to communicate with the ECM. The shutdown switch must be returned to the RUN position before the ECM will allow the engine to start.The ECM reads the position of the shutdown switch. If the engine is running, the ECM disables the fuel injection. The status screen will display"Injection Disabled" and "Remote Shutdown".
Illustration 1 g03018516
Schematic
Table 2
Troubleshooting Test Steps    Values    Results    
1. Determine the Diagnostic Code
A. Establish communication between Cat® ET and the ECM. Refer to Troubleshooting, "Electronic Service Tools", if necessary.
B. Observe the "Active Diagnostic" screen on Cat ET. Wait at least 30 seconds so that any codes may become active.
C. Look for these codes:
E678 or 4215-31
267-3 or 4215-3
267-4 or 4215-4
   
Diagnostic Trouble codes    
Result: A E678 or 4215-31 diagnostic code is active.
Proceed to Test Step 2.
Result: A 267-3 or 4215-3 diagnostic code is active.
Proceed to Test Step 3.
Result: A 267-4 or 4215-4 diagnostic code is active.
Proceed to Test Step 4.
   
2. Check the Status of the Shutdown Switch on Cat ET
A. Activate the shutdown.
B. Use Cat ET to verify that the engine rpm is 0. Return the shutdown switch to the RUN position.
C. Use Cat ET to observe the status of the shutdown switch.
   
Switch Status
   
Result: The status of the shutdown switch changed states after returning the shutdown switch to the RUN position.
The shutdown switch is operating correctly.
Result: The status of the shutdown switch does not change states after returning the shutdown switch to the RUN position.
Proceed to Test Step 3.
   
3. Create a Short at the Connector for the Shutdown Switch
A. Turn the keyswitch to the OFF position.
B. Disconnect the connector for the shutdown switch.
C. Create a short circuit at the connector for the shutdown switch between