Information:
T2a - Undesired Electrical System Current - Test (For Machines Equipped With a Main Disconnect Switch)
Turn off all of the accessories. Turn the keyswitch to the OFF position.
Clamp a 9U-5795 Current Probe or 225-8266 Ammeter Tool Gp around the main ground cable. Clamp the tool with the positive side away from the battery. Reset the probe (zero) before you clamp the probe around the wire. Read the current. Expected Result: The current is below 2 A.Results:
YES - The current is below 2 A. Continue to Step 3.
NO - The current is above 2 A. There is a current draw in the system. Go to Testing and Adjusting, "T5 Alternator Current - Test"
Turn the disconnect switch to the ON position. Connect a multimeter across the disconnect switch terminals. Connect the red lead to the terminal on the frame side. Connect the black lead to the terminal on the battery side. Use the 10A connections in order to avoid damage.
Turn off the disconnect switch and read the current. Expected Result: The current is below .050 amperes (50 mA).Note: The standard acceptable current draw is 50 mA. A current draw above 50 mA usually indicates a problem. However, some large machines with multiple electronic control modules have a higher acceptable limit. Contact a Caterpillar dealer
Turn off all of the accessories. Turn the keyswitch to the OFF position.
Clamp a 9U-5795 Current Probe or 225-8266 Ammeter Tool Gp around the main ground cable. Clamp the tool with the positive side away from the battery. Reset the probe (zero) before you clamp the probe around the wire. Read the current. Expected Result: The current is below 2 A.Results:
YES - The current is below 2 A. Continue to Step 3.
NO - The current is above 2 A. There is a current draw in the system. Go to Testing and Adjusting, "T5 Alternator Current - Test"
Turn the disconnect switch to the ON position. Connect a multimeter across the disconnect switch terminals. Connect the red lead to the terminal on the frame side. Connect the black lead to the terminal on the battery side. Use the 10A connections in order to avoid damage.
Turn off the disconnect switch and read the current. Expected Result: The current is below .050 amperes (50 mA).Note: The standard acceptable current draw is 50 mA. A current draw above 50 mA usually indicates a problem. However, some large machines with multiple electronic control modules have a higher acceptable limit. Contact a Caterpillar dealer
Parts retainer Caterpillar catalog:
7U6609
RETAINER
Caterpillar
Caterpillar
7U6607
RETAINER-HITCH
Caterpillar
Caterpillar
7U2266
RETAINER
Caterpillar
Caterpillar
7T7159
RETAINER
Caterpillar
Caterpillar
7S8204
RETAINER-SEAL
Caterpillar
Caterpillar
7S8203
RETAINER
Caterpillar
Caterpillar
7X4494
RETAINER
Caterpillar
Caterpillar
7X3457
RETAINER
Caterpillar
Caterpillar
7W5721
RETAINER
Caterpillar
Caterpillar
7W4227
RETAINER A
Caterpillar
Caterpillar
7W1748
RETAINER
Caterpillar
Caterpillar
7W1528
RETAINER
Caterpillar
Caterpillar