7W5327 RETAINER ASSEM Caterpillar parts
980C
Rating:
Alternative (cross code) number:
CA7W5327
7W-5327
7W5327
CA7W5327
7W-5327
7W5327
WHEEL LOADER,
Compatible equipment models: 7W5327:
Information:
Recommended Periodic Insulation Tests
The high voltage that is produced by an operating generator set can cause severe injury or death. Before performing any maintenance or repairs, ensure that the generator will not start.Place the engine control switch in the "OFF" position. Attach "DO NOT OPERATE" tags to all starting controls. Disconnect the batteries or disable the starting system. Lock out all switchgear and automatic transfer switches that are associated with the generator.
Table 1
Tools Needed
Part Number Part Name Quantity
300-8648 Low Voltage Insulation Testing Gp 1
349-4206 High Voltage Insulation Testing Gp 1 Periodically, use an insulation tester to check the insulation resistance of the generator main stator winding. The frequency of this test is determined by the generator environment. Previous insulation tester readings will also determine the frequency of this test.Test the main stator windings with an insulation tester in the following situations:
The generator set is started for the first time.
The generator set is removed from storage.
The generator set is operating in a humid environment. Test every 3 months.
The generator set is not protected from the elements in an enclosed area. Test every 3 months.
The generator set is installed in an enclosed area. This area needs to be low in humidity and this area needs to have steady temperatures. Test every 12 months (minimum).
The generator set has not been run under load for 3 months. Test the generator set weekly. Use space heaters around the generator set if the generator is exposed to a sea water environment or if the humidity is above 75 percent. Also use space heaters if a test result was below 3 megohms.Space heaters must be used whenever the generator set is not under load. Space heaters must also be used whenever salt is present or whenever high humidity is present. Using a space heater in this fashion is the only way to maintain insulation tester readings above 1 megohm. Use space heaters only when the generator is not running.For additional information, refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".Recommended Procedure for the Insulation Test
Personal injury or death can result from electrocution.The megohmmeter is applying a high voltage to the circuit.To avoid electrocution, do not touch the instrument leads without first discharging them. When finished testing also discharge the generator windings.
Take the generator out of service.
Visually inspect the generator for moisture. If moisture exists, do not perform this insulation test. Dry the unit first. Refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".
Inspect the installation. Determine the equipment that will be tested by the insulation tester.
Discharge the capacitance of the windings.
Disconnect "T0" from ground.
Disconnect the sensing lead wires for the regulator by unplugging the harness connectors.
Disconnect the PT leads of the load share module.
Connect the insulation tester Black lead to ground.
Connect the insulation tester RED lead to "T0".
Set the voltage to the rated voltage of the generator.
Use the 1 min/10 min Time Resistance Method:
Apply voltage.
Observe the readings at 1 minute intervals. Observe the readings at 10 minute
The high voltage that is produced by an operating generator set can cause severe injury or death. Before performing any maintenance or repairs, ensure that the generator will not start.Place the engine control switch in the "OFF" position. Attach "DO NOT OPERATE" tags to all starting controls. Disconnect the batteries or disable the starting system. Lock out all switchgear and automatic transfer switches that are associated with the generator.
Table 1
Tools Needed
Part Number Part Name Quantity
300-8648 Low Voltage Insulation Testing Gp 1
349-4206 High Voltage Insulation Testing Gp 1 Periodically, use an insulation tester to check the insulation resistance of the generator main stator winding. The frequency of this test is determined by the generator environment. Previous insulation tester readings will also determine the frequency of this test.Test the main stator windings with an insulation tester in the following situations:
The generator set is started for the first time.
The generator set is removed from storage.
The generator set is operating in a humid environment. Test every 3 months.
The generator set is not protected from the elements in an enclosed area. Test every 3 months.
The generator set is installed in an enclosed area. This area needs to be low in humidity and this area needs to have steady temperatures. Test every 12 months (minimum).
The generator set has not been run under load for 3 months. Test the generator set weekly. Use space heaters around the generator set if the generator is exposed to a sea water environment or if the humidity is above 75 percent. Also use space heaters if a test result was below 3 megohms.Space heaters must be used whenever the generator set is not under load. Space heaters must also be used whenever salt is present or whenever high humidity is present. Using a space heater in this fashion is the only way to maintain insulation tester readings above 1 megohm. Use space heaters only when the generator is not running.For additional information, refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".Recommended Procedure for the Insulation Test
Personal injury or death can result from electrocution.The megohmmeter is applying a high voltage to the circuit.To avoid electrocution, do not touch the instrument leads without first discharging them. When finished testing also discharge the generator windings.
Take the generator out of service.
Visually inspect the generator for moisture. If moisture exists, do not perform this insulation test. Dry the unit first. Refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".
Inspect the installation. Determine the equipment that will be tested by the insulation tester.
Discharge the capacitance of the windings.
Disconnect "T0" from ground.
Disconnect the sensing lead wires for the regulator by unplugging the harness connectors.
Disconnect the PT leads of the load share module.
Connect the insulation tester Black lead to ground.
Connect the insulation tester RED lead to "T0".
Set the voltage to the rated voltage of the generator.
Use the 1 min/10 min Time Resistance Method:
Apply voltage.
Observe the readings at 1 minute intervals. Observe the readings at 10 minute
Caterpillar parts catalog:
Parts retainer Caterpillar catalog:
3G9549
RETAINER-G.E.T.
130G, 213B, 214B, 215B, 224B, 225, 235, 235B, 245, 320 L, 651E, 657E, 941, 950, 966D, 966F, 973, 977, 977L, 980B, 980C, 980F, 988, 988B, D5B, D7G, E200B, E240, E240C, E300, E300B, EL240B
130G, 213B, 214B, 215B, 224B, 225, 235, 235B, 245, 320 L, 651E, 657E, 941, 950, 966D, 966F, 973, 977, 977L, 980B, 980C, 980F, 988, 988B, D5B, D7G, E200B, E240, E240C, E300, E300B, EL240B
3G2816
RETAINER
215, 215B, 225, 229, 235, 235B, 235D, 245, 245B, 515, 525, 768C, 769C, 769D, 771C, 771D, 772B, 773B, 773D, 775B, 775D, 776, 776C, 776D, 777, 777B, 777D, 784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 7...
215, 215B, 225, 229, 235, 235B, 235D, 245, 245B, 515, 525, 768C, 769C, 769D, 771C, 771D, 772B, 773B, 773D, 775B, 775D, 776, 776C, 776D, 777, 777B, 777D, 784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 7...
6Y9459
RETAINER-G.E.T.
215B, 225, 229, 229D, 325 L, 980C, 988B
215B, 225, 229, 229D, 325 L, 980C, 988B
3S1262
RETAINER
594, 594H, 627, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC, 637, 637B, 637D, 637E, 637G, 769, 826C, 834B, 834G, 834H, 834K, 836, 836G, 836H, 836K, 844, 844H, 844K, 854G, 854K, 972G, 980, 980B, 980C,...
594, 594H, 627, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC, 637, 637B, 637D, 637E, 637G, 769, 826C, 834B, 834G, 834H, 834K, 836, 836G, 836H, 836K, 844, 844H, 844K, 854G, 854K, 972G, 980, 980B, 980C,...
5V4907
RETAINER
518, 518C, 528, 528B, 530B, 613C, 613C II, 814B, 815B, 816B, 824C, 826C, 916, 920, 926, 930, 936, 936F, 950, 950B, 950B/950E, 950F, 950F II, 966D, 966F, 970F, 980C, 980F, D250B, D25C, D300B, D30C, D35...
518, 518C, 528, 528B, 530B, 613C, 613C II, 814B, 815B, 816B, 824C, 826C, 916, 920, 926, 930, 936, 936F, 950, 950B, 950B/950E, 950F, 950F II, 966D, 966F, 970F, 980C, 980F, D250B, D25C, D300B, D30C, D35...
4D2305
RETAINER
613C, 621E, 631E, 641B, 657, 769C, 769D, 771C, 771D, 772, 773B, 773D, 775B, 775D, 776C, 776D, 777, 777D, 784B, 785B, 789B, 793B, 793C, 920, 926, 930, 936F, 950, 950F, 950F II, 966C, 966D, 966F, 966F I...
613C, 621E, 631E, 641B, 657, 769C, 769D, 771C, 771D, 772, 773B, 773D, 775B, 775D, 776C, 776D, 777, 777D, 784B, 785B, 789B, 793B, 793C, 920, 926, 930, 936F, 950, 950F, 950F II, 966C, 966D, 966F, 966F I...
1S3612
RETAINER-VALVE
613C, 621E, 631E, 641B, 657, 769C, 769D, 771C, 771D, 772, 773B, 773D, 775B, 775D, 776C, 776D, 777, 777D, 784B, 785B, 789B, 793B, 793C, 920, 926, 930, 936F, 950, 950F, 950F II, 966C, 966D, 966F, 966F I...
613C, 621E, 631E, 641B, 657, 769C, 769D, 771C, 771D, 772, 773B, 773D, 775B, 775D, 776C, 776D, 777, 777D, 784B, 785B, 789B, 793B, 793C, 920, 926, 930, 936F, 950, 950F, 950F II, 966C, 966D, 966F, 966F I...
1V9809
RETAINER
814B, 815B, 824C, 826C, 834B, 836, 916, 926, 936, 936F, 950B, 950F, 950F II, 966D, 966F, 980C, 980F, 988B, 992C, 994, G936, IT18B, IT28B
814B, 815B, 824C, 826C, 834B, 836, 916, 926, 936, 936F, 950B, 950F, 950F II, 966D, 966F, 980C, 980F, 988B, 992C, 994, G936, IT18B, IT28B
8R7425
RETAINER
824C, 824G, 824G II, 824H, 824K, 825G, 825G II, 825H, 825K, 826G, 826G II, 826H, 826K, 980C, 980F, 980F II, 980G, 980G II, 980H, 980K, 980K HLG, 980M, 982M, AD30, D40D, R1700 II, R1700G
824C, 824G, 824G II, 824H, 824K, 825G, 825G II, 825H, 825K, 826G, 826G II, 826H, 826K, 980C, 980F, 980F II, 980G, 980G II, 980H, 980K, 980K HLG, 980M, 982M, AD30, D40D, R1700 II, R1700G
5K3968
RETAINER-BEARING
825C, 826C, 834B, 834G, 834H, 834K, 836, 836G, 836H, 836K, 980, 980B, 980C, 986H, 988B, 988F, 988F II, 988G, 988H, 988K, 994, 994D, 994F, 994H, AD40, AD45, AD45B, AD55, AD55B, AD60, AE40, AE40 II, R29...
825C, 826C, 834B, 834G, 834H, 834K, 836, 836G, 836H, 836K, 980, 980B, 980C, 986H, 988B, 988F, 988F II, 988G, 988H, 988K, 994, 994D, 994F, 994H, AD40, AD45, AD45B, AD55, AD55B, AD60, AE40, AE40 II, R29...
5K4268
RETAINER-BEARING
824C, 980, 980B, 980C, 980F, R1700 II
824C, 980, 980B, 980C, 980F, R1700 II
6W4733
RETAINER-BEARING
980C, 980F, 980F II, R1700 II
980C, 980F, 980F II, R1700 II
4Y0300
RETAINER
980C, 980F
980C, 980F
4V6167
RETAINER
950
950
1297848
RETAINER
966H
966H
3Y1110
RETAINER
950
950
3Y1629
RETAINER
966C
966C
1425636
RETAINER
793B, 793C, 793D, 793F, 793F OEM, 793F-XQ
793B, 793C, 793D, 793F, 793F OEM, 793F-XQ
1425635
RETAINER
793B, 793C
793B, 793C
6T7531
RETAINER
69D, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 776C, 776D, 777, 777D, 784B, 784C, 785B, 785C, 789B, 789C, 793B, 793C, 793D
69D, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 776C, 776D, 777, 777D, 784B, 784C, 785B, 785C, 789B, 789C, 793B, 793C, 793D
2102587
RETAINER
793C, 793D
793C, 793D
9X9067
RETAINER
950F
950F
4Y5156
RETAINER
966F, 980F
966F, 980F