The user is unable to view the custom event at all.Test Step 1. ENSURE THAT THE EVENT INPUT FUNCTION IS CONFIGURED FOR THE CUSTOM EVENTIn order to show the custom text string in the event log, the "EVENT INPUT FUNCTION #X SUSPECT PARAMETER NUMBER" must be configured for a special type of event called "CUSTOM EVENT". The "FAILURE MODE IDENTIFIER" must be set to "STATUS (CONDITION EXISTS)". Navigate to the "I/O STATUS" screen by pressing the main menu button, selecting "VIEW", navigate to "DIGITAL INPUTS", then navigate to the input that should be programmed for the custom event and press "OK".Expected Result:The "Event Input Function #X Suspect Parameter Number" is configured for "Custom Event" and the "Event Input Function #X Failure Mode Identifier" is configured for "Status".Results:
OK - The setpoints are configured correctly. Proceed to Test Step 2.
NOT OK - The setpoints need changed. You need either security level 2 access, or access to Cat ET, to change these setpoints. If changing the "Suspect Parameter Number" setpoint from the control panel display, ensure that the input is programmed with the usage type as "System Event", event parameter as "Custom Event" under "Others", and failure type as "Status".STOPTest Step 2. CHECK FOR WIRING PROBLEMS
From the "MAIN MENU" screen, select "VIEW", then select "I/O STATUS".
Activate the input. Ensure that the appropriate input indication changes. Expected Result:When you flip the switch that is wired between the proper input pin and BATT- for non-isolated inputs or reference for isolated inputs, the "I/O STATUS" screen indication changes from a hyphen (-) to a number, or letter, depending on which number input is switched. If you are in the detailed screen, it changes to "ACTIVE" from "INACTIVE"Results:
OK - The wiring and indication on the EMCP 4 are OK. Proceed to Test Step 3
NOT OK - The wiring needs correction.Repair: Repair the wiring. The input should be wired between the appropriate digital input pin and the reference for that input.STOPTest Step 3. CHECK THAT THE EVENT RESPONSE IS ENABLEDEach event, such as "Custom Event #1 Condition Exists", has an associated event response configuration. The event response configuration must be enabled for the event to show up in the event log.Expected Result:The "Custom Event #X Condition Exists Event Response Configuration" for the particular custom event you are trying to trigger, should be set to "Warning", "Soft Shutdown", "Hard Shutdown" or "Active Only" (other settings are optional).Results:
OK - The setpoint is already configured.Repair: Call the customer support representative for further assistance.STOP
NOT OK - Change the setpoint. You need either security level 2 access, or access to Cat ET, to change this setpoint. Make sure the ECS is set to stop before attempting to change this setpoint. STOP
OK - The setpoints are configured correctly. Proceed to Test Step 2.
NOT OK - The setpoints need changed. You need either security level 2 access, or access to Cat ET, to change these setpoints. If changing the "Suspect Parameter Number" setpoint from the control panel display, ensure that the input is programmed with the usage type as "System Event", event parameter as "Custom Event" under "Others", and failure type as "Status".STOPTest Step 2. CHECK FOR WIRING PROBLEMS
From the "MAIN MENU" screen, select "VIEW", then select "I/O STATUS".
Activate the input. Ensure that the appropriate input indication changes. Expected Result:When you flip the switch that is wired between the proper input pin and BATT- for non-isolated inputs or reference for isolated inputs, the "I/O STATUS" screen indication changes from a hyphen (-) to a number, or letter, depending on which number input is switched. If you are in the detailed screen, it changes to "ACTIVE" from "INACTIVE"Results:
OK - The wiring and indication on the EMCP 4 are OK. Proceed to Test Step 3
NOT OK - The wiring needs correction.Repair: Repair the wiring. The input should be wired between the appropriate digital input pin and the reference for that input.STOPTest Step 3. CHECK THAT THE EVENT RESPONSE IS ENABLEDEach event, such as "Custom Event #1 Condition Exists", has an associated event response configuration. The event response configuration must be enabled for the event to show up in the event log.Expected Result:The "Custom Event #X Condition Exists Event Response Configuration" for the particular custom event you are trying to trigger, should be set to "Warning", "Soft Shutdown", "Hard Shutdown" or "Active Only" (other settings are optional).Results:
OK - The setpoint is already configured.Repair: Call the customer support representative for further assistance.STOP
NOT OK - Change the setpoint. You need either security level 2 access, or access to Cat ET, to change this setpoint. Make sure the ECS is set to stop before attempting to change this setpoint. STOP
Caterpillar SIS machinery equipment:
Caterpillar SIS
621 TRACTOR 23H02223-04298 (MACHINE) »
9S-6889
RETARDER CONTROL GROUP
627 SCRAPERS 50K00001-00865 (MACHINE) »
9S-6889
RETARDER CONTROL GROUP
627 TRACTORS 54K00001-00770 (MACHINE) »
9S-6889
RETARDER CONTROL GROUP
650B & 660B TRACTORS 58K00001-UP (MACHINE) »
9S-6889
RETARDER CONTROL GROUP
666B TRACTOR 66K00001-UP (MACHINE) POWERED BY D346 ENGINE »
9S-6889
RETARDER CONTROL GROUP
657B TRACTOR 68K00001-00892 (MACHINE) »
9S-6889
RETARDER CONTROL GROUP
641B & 651B TRACTORS 65K00001-00984 (MACHINE) »
9S-6889
RETARDER CONTROL GROUP
631C TRACTOR 67M00001-04580 (MACHINE) »
9S-6889
RETARDER CONTROL GROUP
633C TRACTOR 66M00001-00781 (MACHINE) »
9S-6889
RETARDER CONTROL GROUP
637 TRACTORS 65M00001-UP (MACHINE) »
9S-6889
RETARDER CONTROL GROUP
637 SCRAPERS 64M00001-UP (MACHINE) »
9S-6889
RETARDER CONTROL GROUP
657B SCRAPERS 47M00001-UP (MACHINE) »
9S-6889
RETARDER CONTROL GROUP
666B SCRAPER 20G00242-UP (MACHINE) POWERED BY D343 ENGINE »
9S-6889
RETARDER CONTROL GROUP
627 SCRAPERS 50K00826-UP (MACHINE) »
9S-6889
RETARDER CONTROL GROUP
Caterpillar parts catalog:
Parts retarder Caterpillar catalog:
7D4940
RETARDER CONTROL AND LINES GROUP
631C, 633C
631C, 633C
9S8088
RETARDER OIL COOLER GROUP
631C, 633C, 637
631C, 633C, 637
3P7018
RETARDER GP
631D, 631E, 633D, 637D, 637E, 639D
631D, 631E, 633D, 637D, 637E, 639D
2S0534
RETARDER OIL COOLER GROUP
621, 623
621, 623
6P3158
RETARDER & TORQUE CONVERTER
637D, 637E, 637G, 639D
637D, 637E, 637G, 639D
8S0550
RETARDER GROUP
631C, 633C, 637
631C, 633C, 637
1887179
RETARDER AR
631G
631G
1603554
RETARDER AR
621G, 623G
621G, 623G