4J2620 RING Caterpillar parts
6A, 814B, 814F, 814F II, 824G, 824G II, 824H, 824K, 825G, 825G II, 825H, 825K, 826G, 826G II, 826H, 826K, 930, 930R, 950, 955K, 955L, 980C, 980F, 980G
Rating:
Alternative (cross code) number:
CA4J2620
4J-2620
4J2620
CA4J2620
4J-2620
4J2620
Weight: 0.20 pounds 0 kg.
Information:
AXIAL WIDTH
37.74
mm
ID
0
mm
MATERIAL
Nylon
OD
114.3
mm
THICKNESS
3.2
mm
TYPE
PISTON
BULLDOZER, WHEEL LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
4J2620
Images:
Compatible equipment models: 4J2620:
Information:
Reading the ID of a Key
Before you can operate the machine, the machine security system MSS must identify a valid electronic key ID.When the key is turned to the ON position, the MSS enters the read mode. The MSS then checks for a valid electronic key ID. If the electronic key ID matches an electronic key ID that is stored in the ECM, then the critical ECM functions are enabled. An "enable" message is also sent via the CAT data link or J1939 data link to the other electronic control modules that are on the machine. The machine will operate normally.Note: Ensure that you have only one electronic key near the exciter coil when the MSS reads the key. If there is more than one key, the ECM will not be able to read the key and the machine will not start.Note: If the ECM has failed or has been removed, the other critical machine operations controlled by the other electronic control modules will not operate.Armed
When the MSS is armed, critical machine functions are disabled. The MSS disables the power that is supplied to each component that is powered by the output drivers. The machine will not be able to operate normally.There are two states of operation within the "armed" mode.
"Key Position OFF"When no power is applied to the MSS, the MSS will default to "armed" state. When power is applied to the MSS and the Grace Period has expired, the MSS will return to the "MSS Armed".
"Key Position ON"When the key switch is first moved to the ON position, the MSS tries to read the electronic key ID. The ECM will continue reading attempts until an ID is read or the read time-out expires. If the key is not read after several attempts, the MSS turns on the red LED of the status indicator and the MSS remains armed.Note: Ensure that you have only one electronic key near the exciter coil when the MSS reads the key. If there is more than one key, the ECM will not be able to read the key and the machine will not start.Disarmed
When the MSS is disarmed, normal machine operation is allowed. A message is sent to the other machine ECM"s over the Cat data link or J1939 data link. The machine will be able to start. The green LED on the status indicator will illuminate.There are two ways to disarm the machine:
Use a valid electronic key for this machine.
Use Cat Electronic Technician® (Cat ET) to configure the MSS bypass schedule to allow machine operations during scheduled periods of time during the week.Electronic Key
After a machine has been started successfully, the operator will have 30 seconds after the machine is turned off before the MSS is automatically armed. The operator is not required to arm the system manually.During the 30 second grace period any key (electronic and non-electronic) will start the machine without key identification validation. When the 30 second grace period expires, the MSS will automatically rearm.If the MSS
Before you can operate the machine, the machine security system MSS must identify a valid electronic key ID.When the key is turned to the ON position, the MSS enters the read mode. The MSS then checks for a valid electronic key ID. If the electronic key ID matches an electronic key ID that is stored in the ECM, then the critical ECM functions are enabled. An "enable" message is also sent via the CAT data link or J1939 data link to the other electronic control modules that are on the machine. The machine will operate normally.Note: Ensure that you have only one electronic key near the exciter coil when the MSS reads the key. If there is more than one key, the ECM will not be able to read the key and the machine will not start.Note: If the ECM has failed or has been removed, the other critical machine operations controlled by the other electronic control modules will not operate.Armed
When the MSS is armed, critical machine functions are disabled. The MSS disables the power that is supplied to each component that is powered by the output drivers. The machine will not be able to operate normally.There are two states of operation within the "armed" mode.
"Key Position OFF"When no power is applied to the MSS, the MSS will default to "armed" state. When power is applied to the MSS and the Grace Period has expired, the MSS will return to the "MSS Armed".
"Key Position ON"When the key switch is first moved to the ON position, the MSS tries to read the electronic key ID. The ECM will continue reading attempts until an ID is read or the read time-out expires. If the key is not read after several attempts, the MSS turns on the red LED of the status indicator and the MSS remains armed.Note: Ensure that you have only one electronic key near the exciter coil when the MSS reads the key. If there is more than one key, the ECM will not be able to read the key and the machine will not start.Disarmed
When the MSS is disarmed, normal machine operation is allowed. A message is sent to the other machine ECM"s over the Cat data link or J1939 data link. The machine will be able to start. The green LED on the status indicator will illuminate.There are two ways to disarm the machine:
Use a valid electronic key for this machine.
Use Cat Electronic Technician® (Cat ET) to configure the MSS bypass schedule to allow machine operations during scheduled periods of time during the week.Electronic Key
After a machine has been started successfully, the operator will have 30 seconds after the machine is turned off before the MSS is automatically armed. The operator is not required to arm the system manually.During the 30 second grace period any key (electronic and non-electronic) will start the machine without key identification validation. When the 30 second grace period expires, the MSS will automatically rearm.If the MSS
Caterpillar parts catalog:
Parts ring Caterpillar catalog:
1V8578
RING-SNAP
824C, 980C, 980F, 980F II, AD40, AE40, D40D, R1700 II
824C, 980C, 980F, 980F II, AD40, AE40, D40D, R1700 II
3D2051
RING-LOCK
824C, 980, 980B, 980C, 980F, 980F II, AD40, AE40, D35C, D40D, D44B, D550B, R1700 II
824C, 980, 980B, 980C, 980F, 980F II, AD40, AE40, D35C, D40D, D44B, D550B, R1700 II
9J5562
RING-WEAR
5130, 980C, 980F, 980F II, R1600, R1600G, R1600H
5130, 980C, 980F, 980F II, R1600, R1600G, R1600H
4T3107
RING-BACKUP
777B, 777D, 980C, 980F, 980F II, D8L, D8N, R1600, R1600G, R1600H
777B, 777D, 980C, 980F, 980F II, D8L, D8N, R1600, R1600G, R1600H
8E5268
RING-SEAL
824C, 826C, 980C
824C, 826C, 980C
5K1556
RING
814, 815, 816, 824B, 826B, 834, 950, 966C, 980, 980B, 988, 992
814, 815, 816, 824B, 826B, 834, 950, 966C, 980, 980B, 988, 992
4K9603
RING
814, 815, 816, 824B, 826B, 834, 950, 966C, 980, 980B, 988, 992
814, 815, 816, 824B, 826B, 834, 950, 966C, 980, 980B, 988, 992
7K0114
RING
814, 815, 816, 824B, 826B, 834, 950, 966C, 980, 980B, 988, 992
814, 815, 816, 824B, 826B, 834, 950, 966C, 980, 980B, 988, 992
7S3004
RING
950, 966C, D10, D11N, D11R, D11T
950, 966C, D10, D11N, D11R, D11T
3P3559
RING
824B, 824C, 980C
824B, 824C, 980C
8P1121
RING
814B, 815B, 966D
814B, 815B, 966D
5P3235
RING
980C, D8L
980C, D8L
4F2200
RING
127, 25, 619
127, 25, 619
4F2198
RING
127, 25, 619
127, 25, 619
4J0973
RING
141, 191, 621, 769, 824S, 950, 988
141, 191, 621, 769, 824S, 950, 988
1S5052
RING
561B, 951B, 955H, 955K
561B, 951B, 955H, 955K
2J0745
RING
8B, 9A
8B, 9A
0206648
RING
183B
183B
8S2358
RING GROUP
955K
955K
3K8267
RING
163, 955H
163, 955H
3J9365
RING
977H
977H
3S4672
RING
594, 633D, D9G
594, 633D, D9G
5J1255
RING
153, 163, 950, 955K
153, 163, 950, 955K
4K1791
RING
163, 172, 183B, 621, 950
163, 172, 183B, 621, 950