5T6667 RING-RETAINING Caterpillar parts
784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D, 793, 793B, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 797
Rating:
Alternative (cross code) number:
CA5T6667
5T-6667
5T6667
CA5T6667
5T-6667
5T6667
Weight: 0.06 pounds 0 kg.
Information:
OD
122.56
mm
THICKNESS
2.36
mm
TYPE
RECT SECT
TRACTOR, TRUCK,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
CTP 5T6667 Retaining Ring for Heavy Equipment
CTP Ring Only || Sold in each || Easy in-and-out fit
CTP Ring Only || Sold in each || Easy in-and-out fit
$9.09
14 Feb 2024
Amazon.com
CTP 5T6667 Retaining Ring for Heavy Equipment
CTP Ring Only || Sold in each || Easy in-and-out fit
CTP Ring Only || Sold in each || Easy in-and-out fit
Compatible equipment models: 5T6667:
Information:
The sequence for start-up of the scanner occurs during engine warm-up. The start-up for the scanner helps prevent unnecessary activation of alarms. The sequence consists of three basic steps:
The input for engine rotation is allowed to open. This activates the setpoints.
The setpoints are armed when the temperature rises to the programmed value.
The start-up timer is activated.
The start-up timer expires and all of the alarms are armed. Each condition must be met before the next condition occurs. If the achieved status of any prior condition is lost, the sequence will restart from that condition.Not all of the alarms require all three steps in order to be armed. Table 1 lists the alarms and the conditions that are programmed at the factory for arming of the alarms. For more information on the alarms, refer to Systems Operation, "Setpoints" and Systems Operation, "Alarm Description".
Table 1
Alarms and Default Conditions for Arming of the Alarms    
Alarm     Condition    
"CYL DEV"     The circuit for the input for engine rotation is open.
The temperature for arming of the parameters is achieved.
The start-up timer has expired.    
"CYL HI 1"    
"CYL HI 2"    
"TO HI 1"     The circuit for the input for engine rotation is open.    
"TO HI 2"    
"TI HI"    Note: Any alarm can be configured to be armed by the input for engine rotation only. Any alarm can also be configured to be armed by all of the conditions. However, custom wiring, a computer, and the proper software are required. For more information, consult the appropriate Caterpillar Engine Customer Service.Input for Engine Rotation - It is important for the circuit of this input to be open during normal engine operation. When the circuit is open, the scanner can activate alarms.When the circuit is grounded, all the alarms are deactivated and the engine is not protected against problems with exhaust temperatures.It is not necessary to connect the circuit for input of engine rotation. The circuit is left open by the factory.Note: The arming temperature and the start-up timer are adjusted with the "SETPTS" menu. Refer to Systems Operation, "System Configuration Parameters".Arming Temperature - To arm the alarms, the average cylinder temperature must rise above the arming temperature. This temperature can be reprogrammed with the keypad.The average cylinder temperature must stay above the arming temperature during normal operation. If the average cylinder temperature becomes less than the arming temperature, the alarms that depend on the arming temperature are deactivated.Start-up Timer - The start-up timer starts when the arming temperature is achieved. When the start-up timer is running, the display shows the time in minutes and in seconds until the timer expires. The display shows "TIMER", "xxm", and "xxs".If no alarms are configured to use the timer, the screen for the start-up timer is not displayed during start-up of the scanner.For arming of the selected alarms, the average cylinder temperature must stay above the arming temperature until the timer expires. Otherwise, the timer restarts.
"ENTER/ACK" key To cancel the
The input for engine rotation is allowed to open. This activates the setpoints.
The setpoints are armed when the temperature rises to the programmed value.
The start-up timer is activated.
The start-up timer expires and all of the alarms are armed. Each condition must be met before the next condition occurs. If the achieved status of any prior condition is lost, the sequence will restart from that condition.Not all of the alarms require all three steps in order to be armed. Table 1 lists the alarms and the conditions that are programmed at the factory for arming of the alarms. For more information on the alarms, refer to Systems Operation, "Setpoints" and Systems Operation, "Alarm Description".
Table 1
Alarms and Default Conditions for Arming of the Alarms    
Alarm     Condition    
"CYL DEV"     The circuit for the input for engine rotation is open.
The temperature for arming of the parameters is achieved.
The start-up timer has expired.    
"CYL HI 1"    
"CYL HI 2"    
"TO HI 1"     The circuit for the input for engine rotation is open.    
"TO HI 2"    
"TI HI"    Note: Any alarm can be configured to be armed by the input for engine rotation only. Any alarm can also be configured to be armed by all of the conditions. However, custom wiring, a computer, and the proper software are required. For more information, consult the appropriate Caterpillar Engine Customer Service.Input for Engine Rotation - It is important for the circuit of this input to be open during normal engine operation. When the circuit is open, the scanner can activate alarms.When the circuit is grounded, all the alarms are deactivated and the engine is not protected against problems with exhaust temperatures.It is not necessary to connect the circuit for input of engine rotation. The circuit is left open by the factory.Note: The arming temperature and the start-up timer are adjusted with the "SETPTS" menu. Refer to Systems Operation, "System Configuration Parameters".Arming Temperature - To arm the alarms, the average cylinder temperature must rise above the arming temperature. This temperature can be reprogrammed with the keypad.The average cylinder temperature must stay above the arming temperature during normal operation. If the average cylinder temperature becomes less than the arming temperature, the alarms that depend on the arming temperature are deactivated.Start-up Timer - The start-up timer starts when the arming temperature is achieved. When the start-up timer is running, the display shows the time in minutes and in seconds until the timer expires. The display shows "TIMER", "xxm", and "xxs".If no alarms are configured to use the timer, the screen for the start-up timer is not displayed during start-up of the scanner.For arming of the selected alarms, the average cylinder temperature must stay above the arming temperature until the timer expires. Otherwise, the timer restarts.
"ENTER/ACK" key To cancel the
Caterpillar parts catalog:
Parts ring Caterpillar catalog:
3196035
RING-BACKUP
793B, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ
793B, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ
4T4825
RING-WEAR
789, 789B, 789C, 789D
789, 789B, 789C, 789D
8T1130
RING-WEAR
789, 789B, 789C, 789D
789, 789B, 789C, 789D
3E6784
RING-BACKUP
789, 789B, 789C, 789D
789, 789B, 789C, 789D
4T4804
RING-BACKUP
785, 789, 789B, 789C, 789D
785, 789, 789B, 789C, 789D
4T6096
RING
789, 789B, 789C, 789D
789, 789B, 789C, 789D
8T6926
RING
789, 789B, 789C, 789D
789, 789B, 789C, 789D
5P9957
RING-RETAINING
793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F XQ, 797, 797B, 797F, D10, D10N, D10R, D11N, D11R, D11T
793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F XQ, 797, 797B, 797F, D10, D10N, D10R, D11N, D11R, D11T
8E6328
RING-SEALING
375, 375 L, 5080, 797, 797B, 797F
375, 375 L, 5080, 797, 797B, 797F
1407097
RING-SEAL
797, 797B, 797F
797, 797B, 797F
1559149
RING-RETAINING
330D L, 330D LN, 330D MH, 345B, 345B II, 345B II MH, 345B L, 345C, 345C L, 345C MH, 385B, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L, 5090B, 797, W345B II, W345C MH
330D L, 330D LN, 330D MH, 345B, 345B II, 345B II MH, 345B L, 345C, 345C L, 345C MH, 385B, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L, 5090B, 797, W345B II, W345C MH
3402376
RING-RETAINING
793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ
793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ
5T7331
RING
784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 793, 793B, 793C, 793D, 797, 797B
784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 793, 793B, 793C, 793D, 797, 797B
2K5340
RING-RETAINING
12E, 140M, 160M, 160M 2, 735, 773B, 773D, 773E, 775B, 775D, 775E, 776C, 776D, 777D, 784B, 784C, 785B, 785C, 785D, 789B, 789C, 789D, 793B, 793C, 793D
12E, 140M, 160M, 160M 2, 735, 773B, 773D, 773E, 775B, 775D, 775E, 776C, 776D, 777D, 784B, 784C, 785B, 785C, 785D, 789B, 789C, 789D, 793B, 793C, 793D
8X2495
RING
793, 793B, 793C, 793D, 793F, 793F CMD, 793F OEM, 793F-XQ
793, 793B, 793C, 793D, 793F, 793F CMD, 793F OEM, 793F-XQ
6G6281
RING
784B, 784C, 785, 785B, 785C, 785D, 793, 793B, 793C, 793D, 793F, 793F CMD, 793F OEM, 793F-XQ
784B, 784C, 785, 785B, 785C, 785D, 793, 793B, 793C, 793D, 793F, 793F CMD, 793F OEM, 793F-XQ
2020969
RING-BACKUP
793B, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ
793B, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ
1944420
RING-WEAR
793B, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ
793B, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ
3E6795
RING-BACKUP
793, 793B, 793C
793, 793B, 793C
6E0247
RING-WEAR
793, 793B, 793C
793, 793B, 793C
6E0249
RING-WEAR
5130, 5130B, 5230, 5230B, 793, 793B, 793C
5130, 5130B, 5230, 5230B, 793, 793B, 793C
1333847
RING-BACKUP
793B, 793C, 797
793B, 793C, 797
1333845
RING-BACKUP
385C, 385C L, 793B, 793C, 797
385C, 385C L, 793B, 793C, 797
1333846
RING-BACKUP
793B, 793C, 797
793B, 793C, 797