7D3462 RING-SEAL Caterpillar parts
769C, 769D, 771C, 771D, 772, 773, 773B, 773D, 775B, 775D, 776C, 776D, 777, 777B, 777D, 784B, 784C, 785, 785B, 785C, 785D, 789B, 789C, 789D, 793B, 793C
Rating:
Alternative (cross code) number:
CA7D3462
7D-3462
7D3462
CA7D3462
7D-3462
7D3462
Weight: 0.60 pounds 0 kg.
QUARRY TRUCK, TRUCK,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
CTP 7D3462 Seal Ring for Heavy Equipment
CTP Ring Only || Sold in each || Easy in-and-out fit
CTP Ring Only || Sold in each || Easy in-and-out fit
CTP 7D3462 Seal Ring for Heavy Equipment
CTP Ring Only || Sold in each || Easy in-and-out fit
CTP Ring Only || Sold in each || Easy in-and-out fit
Compatible equipment models: 7D3462:
Information:
The scanner is calibrated at the factory. The scanner should not require additional calibration. However, the scanner can be calibrated at any time. The calibration is used to calibrate the temperature range of the scanner.Calibration can be performed with the keypad. A 163-0096 Diagnostic and Calibration Tool is required for a reference.Calibration Procedure
Note: Before you perform the calibration, make sure that the units of the calibration tool match the units of the scanner (°C or °F). Calibration must be performed in an environment with low levels of electromagnetic interference (EMI).
Connect a calibration tool to the terminals for channel 1. Refer to Systems Operation, "Wiring". Use wiring of type K.The scanner must be calibrated on channel 1 only. The calibration of channel 1 is the calibration for all of the channels.Note: During the calibration procedure, 60 seconds are allowed between keystrokes. If 60 seconds elapse without a keystroke, the scanner automatically returns to the normal mode. The previous calibration is saved.
Depress the "SETUP" key and simultaneously press the "RESET" and "SETPTS" keys."CAL" (calibration) is displayed.
Press the "ENTER/ACK" key."SET LO PT" is displayed.
Adjust the calibration tool for a very low reading such as 4 °C (40 °F) and press the "ENTER/ACK" key."SAMPLING" is displayed first.
When "ADJUST LO PT" is displayed, use the up arrow key or the down arrow key to change the display in order to match the setting of the calibration tool. Press the "ENTER/ACK" key."SET HI PT" is displayed.
Adjust the calibration tool for a very high reading such as 538 °C (1000 °F) and press the "ENTER/ACK" key."SAMPLING" is displayed first.
When "ADJUST HI PT" is displayed, use the up arrow key or the down arrow key to change the display in order to match the setting of the calibration tool. Press the "ENTER/ACK" key.The new calibration is saved only after the "ENTER/ACK" key is pressed and "SAVED" is displayed.After a successful calibration, "SAVED" is displayed and the scanner returns to the normal screen. The new calibration values are stored in permanent memory.To exit the function without saving any changes, press the "ESC" key before you press the "ENTER/ACK" key.
Note: Before you perform the calibration, make sure that the units of the calibration tool match the units of the scanner (°C or °F). Calibration must be performed in an environment with low levels of electromagnetic interference (EMI).
Connect a calibration tool to the terminals for channel 1. Refer to Systems Operation, "Wiring". Use wiring of type K.The scanner must be calibrated on channel 1 only. The calibration of channel 1 is the calibration for all of the channels.Note: During the calibration procedure, 60 seconds are allowed between keystrokes. If 60 seconds elapse without a keystroke, the scanner automatically returns to the normal mode. The previous calibration is saved.
Depress the "SETUP" key and simultaneously press the "RESET" and "SETPTS" keys."CAL" (calibration) is displayed.
Press the "ENTER/ACK" key."SET LO PT" is displayed.
Adjust the calibration tool for a very low reading such as 4 °C (40 °F) and press the "ENTER/ACK" key."SAMPLING" is displayed first.
When "ADJUST LO PT" is displayed, use the up arrow key or the down arrow key to change the display in order to match the setting of the calibration tool. Press the "ENTER/ACK" key."SET HI PT" is displayed.
Adjust the calibration tool for a very high reading such as 538 °C (1000 °F) and press the "ENTER/ACK" key."SAMPLING" is displayed first.
When "ADJUST HI PT" is displayed, use the up arrow key or the down arrow key to change the display in order to match the setting of the calibration tool. Press the "ENTER/ACK" key.The new calibration is saved only after the "ENTER/ACK" key is pressed and "SAVED" is displayed.After a successful calibration, "SAVED" is displayed and the scanner returns to the normal screen. The new calibration values are stored in permanent memory.To exit the function without saving any changes, press the "ESC" key before you press the "ENTER/ACK" key.
Caterpillar parts catalog:
Parts ring Caterpillar catalog:
3402374
RING-RETAINING
770, 772, 773B, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775B, 775D, 775E, 775F, 775G, 775G LRC, 775G OEM, AD55, AD55B, AD60
770, 772, 773B, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775B, 775D, 775E, 775F, 775G, 775G LRC, 775G OEM, AD55, AD55B, AD60
9W6612
RING-SEALING
769C, 769D, 771C, 771D, D9R, D9T
769C, 769D, 771C, 771D, D9R, D9T
9X7304
RING-SEAL
69D, 769C, 769D, 771C, 771D
69D, 769C, 769D, 771C, 771D
6G1732
RING-LOCK
69D, 768C, 769C, 769D, 770, 770G, 770G OEM, 771C, 771D, 772, 772G, 772G OEM, AD55, AD55B, AD60, R2900G, R3000H
69D, 768C, 769C, 769D, 770, 770G, 770G OEM, 771C, 771D, 772, 772G, 772G OEM, AD55, AD55B, AD60, R2900G, R3000H
8T7693
RING
69D, 769C, 769D, 770, 770G, 770G OEM, 771C, 771D, 772, 772G, 772G OEM
69D, 769C, 769D, 770, 770G, 770G OEM, 771C, 771D, 772, 772G, 772G OEM
3G3470
RING-WEAR
69D, 769C, 769D, 770G, 770G OEM, 771C, 771D, 772G, 772G OEM, 795F AC, 795F XQ, 797F
69D, 769C, 769D, 770G, 770G OEM, 771C, 771D, 772G, 772G OEM, 795F AC, 795F XQ, 797F
3402373
RING-RETAINING
769C, 769D, 770G, 770G OEM, 771C, 771D, 772G, 772G OEM
769C, 769D, 770G, 770G OEM, 771C, 771D, 772G, 772G OEM
7J3300
RING-WEAR
69D, 769C, 769D, 771C, 771D, 773
69D, 769C, 769D, 771C, 771D, 773
8J9936
RING-WEAR
777, 777B, 777D
777, 777B, 777D
8J2577
RING
769, 772, 773, 773B, 776, 777
769, 772, 773, 773B, 776, 777
9J1795
RING
769, 772, 773B, 776, 777
769, 772, 773B, 776, 777
9P3075
RING (.030 OVERSIZE)
16, 768B, 769, 772, 773
16, 768B, 769, 772, 773
3402377
RING-RETAINING
793B, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ
793B, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ
3402375
RING-RETAINING
793B, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ
793B, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ
6E0248
RING-WEAR
793, 793B, 793C
793, 793B, 793C
1152136
RING-BACKUP
793, 793B, 793C
793, 793B, 793C
9X4595
RING-BACKUP
793, 793B, 793C
793, 793B, 793C
3E6795
RING-BACKUP
793, 793B, 793C
793, 793B, 793C
5T6379
RING
776C, 777, 777B, 789, 789B, 789C
776C, 777, 777B, 789, 789B, 789C
5T6378
RING
772B, 773B, 773D, 775B, 775D, 784B, 784C, 785, 785B, 785C
772B, 773B, 773D, 775B, 775D, 784B, 784C, 785, 785B, 785C
5P8403
RING-SEALING
772B, 773B, 776, 777, 777B, 784B, 785, 785B, 789, 789B
772B, 773B, 776, 777, 777B, 784B, 785, 785B, 789, 789B
9X7307
RING-SEAL
772B, 773B, 773D, 773E, 775B, 775D, 775E, 776C, 776D, 777D, 784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D
772B, 773B, 773D, 773E, 775B, 775D, 775E, 776C, 776D, 777D, 784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D
9X2069
RING-RETAINING
345B II, 769D, 771D, 773D, 773E, 775D, 775E, 776D, 777D, 784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D, 793B, 793C, 793D
345B II, 769D, 771D, 773D, 773E, 775D, 775E, 776D, 777D, 784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D, 793B, 793C, 793D