9J4164 RING-WEAR Caterpillar parts
69D, 769C, 769D, 770G, 770G OEM, 771C, 771D, 772G, 772G OEM, 950H, 962H, IT62H
Rating:
Alternative (cross code) number:
CA9J4164
9J-4164
9J4164
CA9J4164
9J-4164
9J4164
Weight: 0.20 pounds 0 kg.
Information:
AXIAL WIDTH
41.02
mm
ID
0
mm
MATERIAL
Nylon
OD
146.05
mm
THICKNESS
3.2
mm
TYPE
PISTON
INTEGRATED TOOLCARRIER, WHEEL LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
9J4164
Images:
Compatible equipment models: 9J4164:
Information:
A typical transfer switch (200 to 400 amp) is shown above. Components are housed inside a standard NEMA 1 enclosure for switches rated 400 amps and below. A NEMA 1 enclosure is a general purpose enclosure for use in clean, dry environments (the enclosure does not have door gaskets).For switches rated more than 400 amps, a NEMA 12 enclosure is provided as standard. NEMA 12 enclosures are non-ventilated, dust-tight and drip-tight. Type 12 enclosures are intended for use indoors to protect the enclosed equipment against fibers, filings, lint, dust, dirt, light splashing, seepage, and external condensation of non-corrosive liquids.In order to maintain the NEMA 12 enclosure, no holes through the enclosure, no conduit knockouts or conduit openings are permitted. Oil-tight or dust-tight mechanisms may be mounted through holes in the enclosure when provided with oil resistant gaskets. Enclosure doors have been factory equipped with oil resistant gaskets. Some transfer switches may have an optional NEMA 3R enclosure. See "Transfer Switch Options" in this manual.Transfer Switch Major Components (Typical 200 To 400 amp)
Switch Position-Normal Indicator Light (1) - Clear light comes on to indicate that load circuits are connected to the normal power source side. Also see transformer T2 (10) and auxiliary contacts on transfer mechanism (15). Switch Position-Standby Indicator Light (2) - Red light comes on to indicate that load circuits are connected to the standby power source side. Also see transformer T2 (10) and auxiliary contacts on transfer mechanism (15). Standby Operating Indicator Light (3) - Amber light comes on to indicate the standby generator has started and is running. Also see transformer T1 (11). Operating Mode Switch SW2 (4) - Use this 3-position switch to select normal automatic operation or any of two different test modes, as follows:1. Automatic Mode - Set switch to this position for normal automatic operation. With AUTOMATIC MODE selected, the system will monitor normal source voltage. Any drop in that source voltage below a pre-set value and for a pre-set time interval will result in an automatic standby generator startup signal and transfer of load circuits to the standby power source, when conditions are correct.2. Normal Test Mode - Setting the switch to NORMAL TEST position will simulate a loss of normal source voltage, and will result in an automatic standby generator startup signal and transfer to the standby power source, just as though an actual normal source failure has occurred. When the switch is reset back to the AUTOMATIC MODE, re-transfer to the normal source and standby generator signal shutdown will occur as pre-set by system
Switch Position-Normal Indicator Light (1) - Clear light comes on to indicate that load circuits are connected to the normal power source side. Also see transformer T2 (10) and auxiliary contacts on transfer mechanism (15). Switch Position-Standby Indicator Light (2) - Red light comes on to indicate that load circuits are connected to the standby power source side. Also see transformer T2 (10) and auxiliary contacts on transfer mechanism (15). Standby Operating Indicator Light (3) - Amber light comes on to indicate the standby generator has started and is running. Also see transformer T1 (11). Operating Mode Switch SW2 (4) - Use this 3-position switch to select normal automatic operation or any of two different test modes, as follows:1. Automatic Mode - Set switch to this position for normal automatic operation. With AUTOMATIC MODE selected, the system will monitor normal source voltage. Any drop in that source voltage below a pre-set value and for a pre-set time interval will result in an automatic standby generator startup signal and transfer of load circuits to the standby power source, when conditions are correct.2. Normal Test Mode - Setting the switch to NORMAL TEST position will simulate a loss of normal source voltage, and will result in an automatic standby generator startup signal and transfer to the standby power source, just as though an actual normal source failure has occurred. When the switch is reset back to the AUTOMATIC MODE, re-transfer to the normal source and standby generator signal shutdown will occur as pre-set by system
Cat SIS web machinery list:
Parts ring Caterpillar catalog:
9X2069
RING-RETAINING
345B II, 769D, 771D, 773D, 773E, 775D, 775E, 776D, 777D, 784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D, 793B, 793C, 793D
345B II, 769D, 771D, 773D, 773E, 775D, 775E, 776D, 777D, 784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D, 793B, 793C, 793D
5J6444
RING-BACKUP
515, 525, 525B, 525C, 535B, 535C, 545, 545C, 69D, 768B, 769, 769C, 769D, 770, 770G, 770G OEM, 771C, 771D, 772, 772G, 772G OEM, 773, 773B, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775B, 775D, 775E, ...
515, 525, 525B, 525C, 535B, 535C, 545, 545C, 69D, 768B, 769, 769C, 769D, 770, 770G, 770G OEM, 771C, 771D, 772, 772G, 772G OEM, 773, 773B, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775B, 775D, 775E, ...
8T7695
RING
69D, 769C, 769D, 770, 770G, 770G OEM, 771C, 771D, 772, 772G, 772G OEM, 773B, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775B, 775D, 775E, 775F, 775G, 775G LRC, 775G OEM
69D, 769C, 769D, 770, 770G, 770G OEM, 771C, 771D, 772, 772G, 772G OEM, 773B, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775B, 775D, 775E, 775F, 775G, 775G LRC, 775G OEM
8T1127
RING-WEAR
69D, 769C, 769D, 770, 770G, 770G OEM, 771C, 771D, 772, 772G, 772G OEM, 773B, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775B, 775D, 775E, 775F, 775G, 775G LRC, 775G OEM
69D, 769C, 769D, 770, 770G, 770G OEM, 771C, 771D, 772, 772G, 772G OEM, 773B, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775B, 775D, 775E, 775F, 775G, 775G LRC, 775G OEM
8T7694
RING-WEAR
69D, 768C, 769C, 769D, 770, 770G, 770G OEM, 771C, 771D, 772, 772B, 772G, 772G OEM, 773B, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775B, 775D, 775E, 775F, 775G, 775G LRC, 775G OEM, AD40, AD45, AD45B...
69D, 768C, 769C, 769D, 770, 770G, 770G OEM, 771C, 771D, 772, 772B, 772G, 772G OEM, 773B, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775B, 775D, 775E, 775F, 775G, 775G LRC, 775G OEM, AD40, AD45, AD45B...
9W6612
RING-SEALING
769C, 769D, 771C, 771D, D9R, D9T
769C, 769D, 771C, 771D, D9R, D9T
9X7304
RING-SEAL
69D, 769C, 769D, 771C, 771D
69D, 769C, 769D, 771C, 771D
6G1732
RING-LOCK
69D, 768C, 769C, 769D, 770, 770G, 770G OEM, 771C, 771D, 772, 772G, 772G OEM, AD55, AD55B, AD60, R2900G, R3000H
69D, 768C, 769C, 769D, 770, 770G, 770G OEM, 771C, 771D, 772, 772G, 772G OEM, AD55, AD55B, AD60, R2900G, R3000H
8T7693
RING
69D, 769C, 769D, 770, 770G, 770G OEM, 771C, 771D, 772, 772G, 772G OEM
69D, 769C, 769D, 770, 770G, 770G OEM, 771C, 771D, 772, 772G, 772G OEM
3G3470
RING-WEAR
69D, 769C, 769D, 770G, 770G OEM, 771C, 771D, 772G, 772G OEM, 795F AC, 795F XQ, 797F
69D, 769C, 769D, 770G, 770G OEM, 771C, 771D, 772G, 772G OEM, 795F AC, 795F XQ, 797F
3402373
RING-RETAINING
769C, 769D, 770G, 770G OEM, 771C, 771D, 772G, 772G OEM
769C, 769D, 770G, 770G OEM, 771C, 771D, 772G, 772G OEM
7J3300
RING-WEAR
69D, 769C, 769D, 771C, 771D, 773
69D, 769C, 769D, 771C, 771D, 773
2462899
RING-BACKUP
950H, 962H, IT62H
950H, 962H, IT62H
2726764
RING-BACKUP
904B
904B
2508713
RING-WEAR
904B, 904H
904B, 904H
2639882
RING-WEAR
904B, 904H
904B, 904H
2508700
RING-RETAINING
901C, 902C, 904B, 904H
901C, 902C, 904B, 904H
2666885
RING-RETAINING
904B, 904H
904B, 904H
1783981
RING
657G
657G
2567280
RING-BACKUP
950H, 950K, 962H, 962K, 966H, 972H, IT62H
950H, 950K, 962H, 962K, 966H, 972H, IT62H
2564363
RING-BACKUP
950H, 950K, 962H, 962K, 966H, 972H, IT62H
950H, 950K, 962H, 962K, 966H, 972H, IT62H
2564362
RING-BACKUP
950H, 950K, 962H, 962K, 966H, 972H, IT62H
950H, 950K, 962H, 962K, 966H, 972H, IT62H
2404695
RING-BACKUP
824K, 950 GC, 950H, 950K, 962H, 962K, 966H, 966M, 966M XE, 972H, 972M, 972M XE, 980H, 980M, 982M, 986H, 988K, 990K, IT62H
824K, 950 GC, 950H, 950K, 962H, 962K, 966H, 966M, 966M XE, 972H, 972M, 972M XE, 980H, 980M, 982M, 986H, 988K, 990K, IT62H
7Y4944
RING-RETAINING
322B L, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 325B L, 325C, 325C FM, 325D FM, 325D FM LL, 328D LCR, 329D LN, 330, 330 FM L, 330 L, 330B, 330B L, 330C, 330C FM, 330C L, 330C MH, 330D, 330D FM, 330D...
322B L, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 325B L, 325C, 325C FM, 325D FM, 325D FM LL, 328D LCR, 329D LN, 330, 330 FM L, 330 L, 330B, 330B L, 330C, 330C FM, 330C L, 330C MH, 330D, 330D FM, 330D...